NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 01:36:30 on December 22, 2011
Entry number 361601
keyword=End_of_Run_2130
****************************
Run Number: 2130
End of Run Comment:
Run_type=Commission,target_type=Carbon,beam_e0=1.72,beam_fraster=off,beam_sraster=off,beam_current=0.51,leftarm_p=1.700,leftarm_theta=5.69,leftarm_sieve=out,septum_current=475,comment_text=BCM low current test 510nA
PRESCALE FACTORS:ps1=0 ps2=0 ps3=2 ps4=0 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : [0]: 524712 [+]: 244902 [-]: 244416
TIME : [0]: 2.954 mins [+]: 1.404 mins [-]: 1.405 mins
LIVE calc. crudely accounts for correlations. Need offline calc.
DEAD TIME: [0]: 6.03% [+]: 8.31% [-]: 8.36%
TRIGGER RATES: PRES/REAL
T1[0] :T1: 0.0/14256.1 Hz T2[0] :T2: 0.0/96.8 Hz T3[0] :T3:3150.3/6300.6 Hz T4[0] :T4: 0.0/39.6 Hz T5[0] :T5: 0.0/0.0 Hz T6[0] :T6: 0.0/10914.1 Hz T7[0] :T7: 0.0/103872.5 Hz T8[0] :T8: 0.0/1024.0 Hz
T1[+] :T1: 0.0/14325.7 Hz T2[+] :T2: 0.0/96.7 Hz T3[+] :T3:3169.7/6339.4 Hz T4[+] :T4: 0.0/40.4 Hz T5[+] :T5: 0.0/0.0 Hz T6[+] :T6: 0.0/10948.5 Hz T7[+] :T7: 0.0/103901.3 Hz T8[+] :T8: 0.0/1024.0 Hz
T1[-] :T1: 0.0/14340.2 Hz T2[-] :T2: 0.0/98.1 Hz T3[-] :T3:3163.4/6326.9 Hz T4[-] :T4: 0.0/38.9 Hz T5[-] :T5: 0.0/0.0 Hz T6[-] :T6: 0.0/10955.1 Hz T7[-] :T7: 0.0/103850.0 Hz T8[-] :T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1[0] :T1: 0/2527103 T2[0] :T2: 0/17161 T3[0] :T3: 558437/1116874 T4[0] :T4: 0/7022 T5[0] :T5: 0/0 T6[0] :T6: 0/1934677 T7[0] :T7: 0/18412922 T8[0] :T8: 0/181519
T1[+] :T1: 0/1207217 T2[+] :T2: 0/8151 T3[+] :T3: 267108/534217 T4[+] :T4: 0/3402 T5[+] :T5: 0/0 T6[+] :T6: 0/922623 T7[+] :T7: 0/8755715 T8[+] :T8: 0/86292
T1[-] :T1: 0/1209074 T2[-] :T2: 0/8275 T3[-] :T3: 266720/533441 T4[-] :T4: 0/3280 T5[-] :T5: 0/0 T6[-] :T6: 0/923662 T7[-] :T7: 0/8755952 T8[-] :T8: 0/86337
AVERAGE CURRENT
BCM 1 : 0.5337 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -3.10231 seconds
APPROXIMATE CURRENT ASYMMETRIES
BCM u1 : 396 ppm
BCM d1 : 307 ppm
APPROXIMATE BCM CHARGES (C)
BCM u1 [0] : 0.0001204
BCM u1 [+] : 5.735E-05
BCM u1 [-] : 5.733E-05
BCM d1 [0] : 6.885E-05
BCM d1 [+] : 3.293E-05
BCM d1 [-] : 3.292E-05
****************************
End-of-run EPICS data for Run Number 2130 at Thu Dec 22 01:36:28 EST 2011
Left Arm Top VDC Current : -1.12305
Left Arm Bottom VDC Current : 29.1992
Left Arm Top VDC voltage : 4.00781
Left Arm Bottom VDC voltage : 3.99756
-----
Right Arm Top VDC Current : -5.61523
Right Arm Bottom VDC Current : -3.95508
Right Arm Top VDC voltage : 4.01611
Right Arm Bottom VDC voltage : 3.97363
-----
Left Arm Q1 momentum : 1.12019
Left Arm Q1 power supply : 842.756
Left Arm Q1 gauss meter : -0.07005
Left Arm Q2 gauss meter : 0.3663
Left Arm Q2 power supply current : 691.931
Left Arm Q2 momentum : 1.6069
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 569.398
Left Arm D1 momentum : 1.69999
Left Arm D1 NMR : 0.629122
Left Arm arm angle : -0.179
Left Arm Q3 gauss meter : -0.41279
Left Arm Q3 power supply current : 817.787
Left Arm Q3 momentum : 2.05413
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.12362
Right Arm Q1 power supply : 844.892
Right Arm Q1 gauss meter : -0.021153
Right Arm Q2 power supply current : 693.27
Right Arm Q2 momentum : 1.61088
Right Arm Q2 gauss meter : 0.3643
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 495.588
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.360498
Right Arm arm angle : 0.197
Right Arm Q3 power supply current : 815.806
Right Arm Q3 momentum : 2.05023
Right Arm Q3 gauss meter : 0.3624
Right Arm Q3 power supply polarity : disabled
-----
HacL_HPE1313A:0_Ch58 : -0.299316
HacL_HPE1313A:0_Ch55 : 23.4375
HacL_HPE1313A:0_Ch54 : -0.0195312
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
Left VDC -DISC LVL Top : 3.90771
Left VDC -DISC LVL Bottom : 3.96387
Left VDC -DISC LVL Voltage1 : 4.97021
Left VDC -DISC LVL Voltage2 : -5.06152
-----
Right Arm Collimator : 0.0598633
HacR_HPE1313A:0_Ch58 : -0.697754
HacR_HPE1313A:0_Ch55 : 22.4121
HacR_HPE1313A:0_Ch54 : -1.02344
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
Left Septum Magnet Current : 475.334
Right Septum Magnet Current : 474.939
-----