• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 16:24:57 on January 9, 2012

    Entry number 361878

    keyword=End_of_Run_2223
    ****************************
     Run Number: 2223
     End of Run Comment:
    Run_type=Cosmics,target_type=empty,comment_text=Rate test
     
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=0   ps4=0   ps5=0   ps6=0   ps7=1   ps8=0   
    
    EVENTS   : [0]: 821389       [+]: 383151       [-]: 382649       
    TIME     : [0]: 1.784 mins  [+]: 0.855 mins  [-]: 0.855 mins  
    
    LIVE calc. crudely accounts for correlations.  Need offline calc. 
    DEAD TIME: [0]:  92.61%      [+]:  92.81%      [-]:  92.82%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :T1: 0.0/14.2 Hz   T2[0] :T2: 0.0/2.9  Hz   T3[0] :T3: 0.0/15.1 Hz   T4[0] :T4: 0.0/4.4  Hz   T5[0] :T5: 0.0/327.0 Hz   T6[0] :T6: 0.0/4220.9 Hz   T7[0] :T7:103876.2/103876.2 Hz   T8[0] :T8: 0.0/1024.0 Hz   
    T1[+] :T1: 0.0/14.3 Hz   T2[+] :T2: 0.0/3.0  Hz   T3[+] :T3: 0.0/15.0 Hz   T4[+] :T4: 0.0/4.6  Hz   T5[+] :T5: 0.0/325.2 Hz   T6[+] :T6: 0.0/4231.2 Hz   T7[+] :T7:103896.9/103896.9 Hz   T8[+] :T8: 0.0/1024.0 Hz   
    T1[-] :T1: 0.0/14.2 Hz   T2[-] :T2: 0.0/2.7  Hz   T3[-] :T3: 0.0/15.2 Hz   T4[-] :T4: 0.0/4.3  Hz   T5[-] :T5: 0.0/328.9 Hz   T6[-] :T6: 0.0/4215.9 Hz   T7[-] :T7:103855.6/103855.6 Hz   T8[-] :T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :T1:      0/1520     T2[0] :T2:      0/308      T3[0] :T3:      0/1612     T4[0] :T4:      0/472      T5[0] :T5:      0/34999    T6[0] :T6:      0/451700   T7[0] :T7:11116380/11116380  T8[0] :T8:      0/109584   
    T1[+] :T1:      0/734      T2[+] :T2:      0/154      T3[+] :T3:      0/769      T4[+] :T4:      0/236      T5[+] :T5:      0/16673    T6[+] :T6:      0/216941   T7[+] :T7:5326950/5326950  T8[+] :T8:      0/52502    
    T1[-] :T1:      0/726      T2[-] :T2:      0/139      T3[-] :T3:      0/778      T4[-] :T4:      0/218      T5[-] :T5:      0/16871    T6[-] :T6:      0/216242   T7[-] :T7:5326962/5326962  T8[-] :T8:      0/52523    
    
    AVERAGE CURRENT
    BCM 1 : 0.1030 uA  
    
     Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -2.71704 seconds
    
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    338.1 ppm     
    BCM d1 :    197.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0] : 8.744E-06      
    BCM u1 [+] : 4.172E-06      
    BCM u1 [-] : 4.171E-06      
    
    BCM d1 [0] : 1.33E-05       
    BCM d1 [+] : 6.358E-06      
    BCM d1 [-] : 6.358E-06      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2223 at Mon Jan 9 16:24:54 EST 2012
    
    Left Arm Top VDC Current : 5.41992
    Left Arm Bottom VDC Current : 15.0391
    Left Arm Top VDC voltage : 4.00928
    Left Arm Bottom VDC voltage : 3.99805
    -----
    Right Arm Top VDC Current : -1.66016
    Right Arm Bottom VDC Current : -3.4668
    Right Arm Top VDC voltage : 4.0127
    Right Arm Bottom VDC voltage : 3.97168
    -----
    Left Arm Q1 momentum : 0.00220769
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0001679
    Left Arm Q2 gauss meter : 0.0010784
    Left Arm Q2 power supply current : -7.86197e-05
    Left Arm Q2 momentum : -6.9555e-08
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : 0.0992235
    Left Arm D1 momentum : 0.00335829
    Left Arm D1 NMR : 0.174967
    Left Arm arm angle : -0.179
    Left Arm Q3 gauss meter : -0.00022827
    Left Arm Q3 power supply current : -0.000346062
    Left Arm Q3 momentum : -1.35111e-06
    Left Arm Q3 power supply polarity : enabled
    -----
    Right Arm Q1 momentum : 0.00589077
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -0.0001479
    Right Arm Q2 power supply current : -0.000559683
    Right Arm Q2 momentum : -5.13347e-08
    Right Arm Q2 gauss meter : 0.0002144
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : -0.000134144
    Right Arm D1 momentum : 0.00414629
    Right Arm D1 NMR : 0.360548
    Right Arm arm angle : 0.197
    Right Arm Q3 power supply current : 7.47261e-05
    Right Arm Q3 momentum : 0.00297157
    Right Arm Q3 gauss meter : 0.0002385
    Right Arm Q3 power supply polarity : enabled
    -----
    HacL_HPE1313A:0_Ch58 : -0.296875
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : -0.0136719
    Left Arm Angle Vernier : 0
    Left Arm Scattering Angle : -0.179
    Left VDC -DISC LVL Top : 3.9043
    Left VDC -DISC LVL Bottom : 3.96045
    Left VDC -DISC LVL Voltage1 : 4.96484
    Left VDC -DISC LVL Voltage2 : -5.05322
    -----
    Right Arm Collimator : -0.000195313
    HacR_HPE1313A:0_Ch58 : -0.695801
    HacR_HPE1313A:0_Ch55 : 22.4609
    HacR_HPE1313A:0_Ch54 : -1.02393
    Right Arm Angle Floor Angle : 0
    Right Arm Angle Vernier : 0
    Right Arm Scattering Angle : 0.197
    Left Septum Magnet Current : 0.0210483
    Right Septum Magnet Current : 0
    -----