NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 20:03:31 on February 28, 2012
Entry number 362472
keyword=End_of_Run_21618
****************************
Run Number: 21618
End of Run Comment:
Run_type=Cosmics,target_type=empty,comment_text=bpm test
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 187)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 21618 at Tue Feb 28 20:03:28 EST 2012
Target Info
Target number in beam : 0
Target encoder position : 0
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 0
Magnetic Field (T) : 0
Magnet Current : 0
VPT 3He (K) : 0
VPT 4He (K) : 0
NMR Area : 0
Polarization : 0
General Run Info
Beam energy (MeV) : 2255.34
Beam Current : 0
Left arm angle : -0.179
Left arm momentum : 0.00388915
Right arm angle : 0.197
Right arm momentum : 0.297468
Left septum current : 0.0841932
Right septum current : 0
Misc Epics Info
-----
Left Arm Q1 momentum : 0.000846463
Left Arm Q1 power supply : 0.213626
Left Arm Q1 gauss meter : 0.0002462
Left Arm Q2 gauss meter : 0.0010641
Left Arm Q2 power supply current : 0.000129641
Left Arm Q2 momentum : -4.98706e-07
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -1.99255
Left Arm D1 momentum : 0.00388915
Left Arm D1 NMR : 0.292622
Left Arm Q3 gauss meter : -0.00071057
Left Arm Q3 power supply current : 0.864653
Left Arm Q3 momentum : 0.00731492
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.136575
Right Arm Q1 power supply : 100.404
Right Arm Q1 gauss meter : -0.0026059
Right Arm Q2 power supply current : 99.6709
Right Arm Q2 momentum : 0.00107266
Right Arm Q2 gauss meter : 0.000223
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.371
Right Arm D1 momentum : 0.297468
Right Arm D1 NMR : 0.360515
Right Arm Q3 power supply current : 0.000231651
Right Arm Q3 momentum : 0.295142
Right Arm Q3 gauss meter : 0.05243
Right Arm Q3 power supply polarity : enabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -60.8504
Wien BDL (Gcm) : -1753
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 132
Laser power Hall A : 0
Half-wave plate (off=out) : OUT
rotating waveplate : 3496
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 0.0841932
Right Septum Magnet Current : 0
-----