NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 21:07:21 on February 29, 2012
Entry number 362564
keyword=End_of_Run_21655
****************************
Run Number: 21655
End of Run Comment:
Run_type=Cosmics,target_type=empty,comment_text=bpm test
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 187)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 21655 at Wed Feb 29 21:07:17 EST 2012
Target Info
Target number in beam : 0
Target encoder position : 0
uWave Frequency (Ghz) : -999
RF Frequency (Mhz) : 213
Magnetic Field (T) : 5.00295
Magnet Current : -999
VPT 3He (K) : 1.21848
VPT 4He (K) : 1.23715
NMR Area : -999
Polarization : -999
General Run Info
Beam energy (MeV) : 2255.34
Beam Current : 0
Left arm angle : -0.179
Left arm momentum : 0.00392812
Right arm angle : 0.197
Right arm momentum : 0.297523
Left septum current : 0.0841932
Right septum current : 0
Misc Epics Info
-----
Left Arm Q1 momentum : 0.000761973
Left Arm Q1 power supply : 0.16022
Left Arm Q1 gauss meter : 0.0002603
Left Arm Q2 gauss meter : 0.05207
Left Arm Q2 power supply current : 97.3277
Left Arm Q2 momentum : 0.228362
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.99247
Left Arm D1 momentum : 0.00392812
Left Arm D1 NMR : 0.219179
Left Arm Q3 gauss meter : -0.00066258
Left Arm Q3 power supply current : 0.863065
Left Arm Q3 momentum : 0.0072092
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.136294
Right Arm Q1 power supply : 100.458
Right Arm Q1 gauss meter : -0.0025905
Right Arm Q2 power supply current : -0.00364531
Right Arm Q2 momentum : -8.92221e-06
Right Arm Q2 gauss meter : 0.0002298
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.371
Right Arm D1 momentum : 0.297523
Right Arm D1 NMR : 0.360502
Right Arm Q3 power supply current : -0.00453587
Right Arm Q3 momentum : -9.41901e-06
Right Arm Q3 gauss meter : 0.0002611
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -60.8504
Wien BDL (Gcm) : -1753
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 132
Laser power Hall A : 0
Half-wave plate (off=out) : IN
rotating waveplate : 329
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 0.0841932
Right Septum Magnet Current : 0
-----