NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 21:30:34 on February 29, 2012
Entry number 362567
keyword=End_of_Run_21659
****************************
Run Number: 21659
End of Run Comment:
Run_type=Cosmics,target_type=empty,comment_text=bpm test
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 187)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 21659 at Wed Feb 29 21:30:30 EST 2012
Target Info
Target number in beam : 0
Target encoder position : 0
uWave Frequency (Ghz) : -999
RF Frequency (Mhz) : 213
Magnetic Field (T) : 5.00295
Magnet Current : -999
VPT 3He (K) : 1.21848
VPT 4He (K) : 1.23715
NMR Area : -999
Polarization : -999
General Run Info
Beam energy (MeV) : 2255.34
Beam Current : 0
Left arm angle : -0.179
Left arm momentum : 0.00379924
Right arm angle : 0.197
Right arm momentum : 0.29755
Left septum current : 0.0841932
Right septum current : 0
Misc Epics Info
-----
Left Arm Q1 momentum : 0.00109367
Left Arm Q1 power supply : 0.16022
Left Arm Q1 gauss meter : 0.0002391
Left Arm Q2 gauss meter : 0.05214
Left Arm Q2 power supply current : 97.3304
Left Arm Q2 momentum : 0.228669
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : -1.98984
Left Arm D1 momentum : 0.00379924
Left Arm D1 NMR : 0.294107
Left Arm Q3 gauss meter : -0.00067165
Left Arm Q3 power supply current : 0.862945
Left Arm Q3 momentum : 0.00729781
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0.136182
Right Arm Q1 power supply : 100.404
Right Arm Q1 gauss meter : -0.0025884
Right Arm Q2 power supply current : -0.00304144
Right Arm Q2 momentum : -7.32703e-06
Right Arm Q2 gauss meter : 0.00023
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 102.371
Right Arm D1 momentum : 0.29755
Right Arm D1 NMR : 0.360475
Right Arm Q3 power supply current : -0.00514116
Right Arm Q3 momentum : -1.15759e-05
Right Arm Q3 gauss meter : 0.0002563
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -60.8504
Wien BDL (Gcm) : -1753
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 132
Laser power Hall A : 0
Half-wave plate (off=out) : IN
rotating waveplate : 329
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 0.0841932
Right Septum Magnet Current : 0
-----