NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 14:41:56 on March 4, 2012
Entry number 363640
keyword=End_of_Run_2750
****************************
Run Number: 2750
End of Run Comment:
Run_type=Optics,target_type=Carbon thin,comment_text=C12(40 mil) fast raster OFF slow raster OFF sieve IN Delta Scan=4.5%
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 190)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 2750 at Sun Mar 4 14:41:49 EST 2012
Target Info
Target number in beam : 0
Target encoder position : 0
uWave Frequency (Ghz) : -999
RF Frequency (Mhz) : -999
Magnetic Field (T) : -999
Magnet Current : -999
VPT 3He (K) : 1.32557
VPT 4He (K) : 1.35274
NMR Area : -999
Polarization : -999
General Run Info
Beam energy (MeV) : 2253.39
Beam Current : 60.27
Left arm angle : 12.502
Left arm momentum : 2.14994
Right arm angle : 12.5005
Right arm momentum : 2.16119
Left septum current : 692.72
Right septum current : 696.347
Misc Epics Info
-----
Left Arm Q1 momentum : 2.14995
Left Arm Q1 power supply : 1098.31
Left Arm Q1 gauss meter : -0.09138
Left Arm Q2 gauss meter : 0.4636
Left Arm Q2 power supply current : 876.152
Left Arm Q2 momentum : 2.14988
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 729.523
Left Arm D1 momentum : 2.14994
Left Arm D1 NMR : 0.795519
Left Arm Q3 gauss meter : -0.52339
Left Arm Q3 power supply current : 1037.32
Left Arm Q3 momentum : 2.14999
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.16048
Right Arm Q1 power supply : 1096.92
Right Arm Q1 gauss meter : -0.02735
Right Arm Q2 power supply current : 882.915
Right Arm Q2 momentum : 2.16101
Right Arm Q2 gauss meter : 0.4648
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 754.258
Right Arm D1 momentum : 2.1612
Right Arm D1 NMR : 0.801994
Right Arm Q3 power supply current : 1040.67
Right Arm Q3 momentum : 2.161
Right Arm Q3 gauss meter : 0.4614
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -60.8504
Wien BDL (Gcm) : -1753
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 108
Laser power Hall A : 0
Half-wave plate (off=out) : OUT
rotating waveplate : 7511
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 692.763
Right Septum Magnet Current : 696.347
-----