NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 16:13:34 on March 6, 2012
Entry number 364236
keyword=End_of_Run_2856
****************************
Run Number: 2856
End of Run Comment:
Run_type=Optics,target_type=empty,comment_text=fast raster off, slow raster off, no target(pure Lhe), delta=0, LQ3=882.3A
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 190)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 2856 at Tue Mar 6 16:13:30 EST 2012
Target Info
Target number in beam : 0
Target encoder position : 0
uWave Frequency (Ghz) : -999
RF Frequency (Mhz) : -999
Magnetic Field (T) : -999
Magnet Current : 121.751
VPT 3He (K) : 1.22093
VPT 4He (K) : 1.24253
NMR Area : -999
Polarization : -999
General Run Info
Beam energy (MeV) : 2252.94
Beam Current : 178.35
Left arm angle : 12.502
Left arm momentum : 2.25106
Right arm angle : 12.5005
Right arm momentum : 2.25097
Left septum current : 950.183
Right septum current : 949.943
Misc Epics Info
-----
Left Arm Q1 momentum : 2.25093
Left Arm Q1 power supply : 1149.9
Left Arm Q1 gauss meter : -0.09566
Left Arm Q2 gauss meter : 0.4854
Left Arm Q2 power supply current : 917.537
Left Arm Q2 momentum : 2.25142
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 767.206
Left Arm D1 momentum : 2.25106
Left Arm D1 NMR : 0.832936
Left Arm Q3 gauss meter : -0.44473
Left Arm Q3 power supply current : 881.252
Left Arm Q3 momentum : 1.82653
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.25115
Right Arm Q1 power supply : 1142.95
Right Arm Q1 gauss meter : -0.02849
Right Arm Q2 power supply current : 919.918
Right Arm Q2 momentum : 2.25158
Right Arm Q2 gauss meter : 0.4841
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 788.171
Right Arm D1 momentum : 2.25097
Right Arm D1 NMR : 0.835307
Right Arm Q3 power supply current : 1083.94
Right Arm Q3 momentum : 2.25087
Right Arm Q3 gauss meter : 0.4805
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -59.6266
Wien BDL (Gcm) : -1721.1
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 110
Laser power Hall A : 0
Half-wave plate (off=out) : IN
rotating waveplate : 329
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 950.183
Right Septum Magnet Current : 949.943
-----