    keyword=G2p Status Update: No beam for rest of the owl shift and Restricted Access Tomorrow to diagonize beamline problems

    Per Yves's suggestion, tomorrow early morning (7am) our hall will go into
    restrict access for Yves and other experts to check the beamline. I asked
    shift works to turn off power supplies of septa and target magnet. Since
    septa are already off, I asked Melissa to follow the procedure of target
    magnet ramp down and turn off the magnet.( I am not totally for sure
    whether we can turn off the field individually) 
    
    Yves should be able to describe the issue more correctly, but here I will
    report what I understand from him about the beamline issue (so may not be
    totally correct):
    
    When Yves tried to tune the beam through chicane to the beam dump, he was
    able to see the beam going through both chicane but he lost the trace of
    beam after target magnet. Our target experts can tell that the beam did
    go through the target chamber, polarization of target field is correct
    and RADCON staff can detect the increase of radiation near the beamline
    after target chamber. Base on Yves's conclusion,the beam is bent too low,
    which indicates the mismatch of chicane field and target field. Experts
    will go down the hall to double check the alignment of new chicane
    location, and meanwhile, Yvies and Jixie need to compare again their
    calculation. 
    


    A copy of this log entry has been emailed to: folts,segal,jpchen,slifer,camsonne,doug,rom,ckeith,jpierce,jixie,roblin