• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 08:12:08 on March 10, 2012

    Entry number 365371

    keyword=End_of_Run_3050
    ****************************
     Run Number: 3050
     End of Run Comment:
    Run_type=Optics,target_type=Carbon thin,comment_text=no LHe, no rasters, delta = 0 beam position scan (0, 4)
     
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=1   ps4=0   ps5=0   ps6=0   ps7=0   ps8=0   
    
    EVENTS   : 311764       
    
    TIME     : 13.886 mins  
    
    DEAD TIME:   2.66%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1: 0.0/862.9 Hz   T2:T2: 0.0/9.2  Hz   T3:T3:384.4/384.4 Hz   T4:T4: 0.0/7.9  Hz   T5:T5: 0.0/1045.9 Hz   T6:T6: 0.0/4522.5 Hz   T7:T7: 0.0/103883.8 Hz   T8:T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:      0/718970   T2:T2:      0/7696     T3:T3: 320312/320312   T4:T4:      0/6605     T5:T5:      0/871437   T6:T6:      0/3768136  T7:T7:      0/86554814  T8:T8:      0/853185   
    
    AVERAGE CURRENT
    BCM 1 : 0.0369 uA  
    
    Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.71697 seconds
    
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :        0 ppm     
    BCM d1 :        0 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 2.017E-05      
    BCM d1 : 4.138E-05      
    
    
    ****************************
    End-of-run EPICS data for Run Number 3050 at Sat Mar 10 08:12:03 EST 2012
    
    

    Target Info

    Target number in beam : 0 Target encoder position : 0 uWave Frequency (Ghz) : 0 RF Frequency (Mhz) : -999 Magnetic Field (T) : -999 Magnet Current : 121.377 VPT 3He (K) : 0 VPT 4He (K) : 1.29048 NMR Area : -999 Polarization : -999

    General Run Info

    Beam energy (MeV) : 2252.94 Beam Current : 0 Left arm angle : -0.179 Left arm momentum : 2.25101 Right arm angle : 0.197 Right arm momentum : 2.228 Left septum current : 725.219 Right septum current : 718.057

    Misc Epics Info

    ----- Left Arm Q1 momentum : 2.25135 Left Arm Q1 power supply : 1150.11 Left Arm Q1 gauss meter : -0.09569 Left Arm Q2 gauss meter : 0.4852 Left Arm Q2 power supply current : 917.231 Left Arm Q2 momentum : 2.25067 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 767.126 Left Arm D1 momentum : 2.25101 Left Arm D1 NMR : 0.832896 Left Arm Q3 gauss meter : -0.54751 Left Arm Q3 power supply current : 1085.85 Left Arm Q3 momentum : 2.25058 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 2.2278 Right Arm Q1 power supply : 1131.1 Right Arm Q1 gauss meter : -0.0283 Right Arm Q2 power supply current : 910.443 Right Arm Q2 momentum : 2.22839 Right Arm Q2 gauss meter : 0.4797 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 779.28 Right Arm D1 momentum : 2.228 Right Arm D1 NMR : 0.826782 Right Arm Q3 power supply current : 1073.13 Right Arm Q3 momentum : 2.22842 Right Arm Q3 gauss meter : 0.4757 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 0 Left Arm Angle Vernier : 0 Left Arm Scattering Angle : -0.179 ----- Right Arm Angle Floor Angle : 0 Right Arm Angle Vernier : 0 Right Arm Scattering Angle : 0.197 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : 88.7125 Wien BDL (First Solenoid) (Gcm) : 1239.7 Wien BDL (Second Solenoid) (Gcm) : 729.5 Wien angle (Horizontal) : -59.6266 Wien BDL (Gcm) : -1721.1 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 110 Laser power Hall A : 0 Half-wave plate (off=out) : OUT rotating waveplate : 3496 Beam Half-wave plate (off=out) : OUT ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 725.198 Right Septum Magnet Current : 718.057 -----