• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 09:12:06 on March12,2012

    Entry number 365944

    Followups:

    keyword=adjust def'n of beam on for auto ABU

    This for the automated ABU numbers in the BTA GUI, which I
    suspect the shift workers have been ignoring with a cynical
    smirk since they've been somewhat unreliable lately.

    Previously, due to the beam leakage, the cut to define "beam on"
    was set at 60 nA. But this has become too high, so now I've made
    it 40 nA. This started at 08:21:49 in the log below. I'm afraid
    this cut will be flakey if this leakage continues to fluctuate.

    Shift workers have final say over ABU numbers in BTA, as usual.
    Units of beam are uA
    Mon Mar 12 08:19:40 EDT 2012 : Beam 0.057349 bm_present = 0 daq_used = 1 Mon Mar 12 08:20:12 EDT 2012 : Beam 0.0573441 bm_present = 0 daq_used = 1 Mon Mar 12 08:20:45 EDT 2012 : Beam 0.0572638 bm_present = 0 daq_used = 1 Mon Mar 12 08:21:17 EDT 2012 : Beam 0.0572491 bm_present = 0 daq_used = 1 Mon Mar 12 08:21:49 EDT 2012 : Beam 0.0573582 bm_present = 1 daq_used = 1 cut fixed Mon Mar 12 08:22:22 EDT 2012 : Beam 0.0574005 bm_present = 1 daq_used = 1 Mon Mar 12 08:22:54 EDT 2012 : Beam 0.0574693 bm_present = 1 daq_used = 1 Mon Mar 12 08:23:26 EDT 2012 : Beam 0.0574107 bm_present = 1 daq_used = 1 Mon Mar 12 08:23:59 EDT 2012 : Beam 0.0574148 bm_present = 1 daq_used = 1 Mon Mar 12 08:24:31 EDT 2012 : Beam 0.0573245 bm_present = 1 daq_used = 1 Mon Mar 12 08:25:04 EDT 2012 : Beam 0.0574107 bm_present = 1 daq_used = 1