NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 08:37:18 on March 17, 2012
Entry number 367090
keyword=End_of_Run_22373
****************************
Run Number: 22373
End of Run Comment:
Run_type=Production,target_type=NH3 top,comment_text=50nA
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 185)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 22373 at Sat Mar 17 08:37:15 EDT 2012
Target Info
Target number in beam : 0
Target encoder position : 48172
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 106.5
Magnetic Field (T) : 2.49865
Magnet Current : 60.882
VPT 3He (K) : 1.15009
VPT 4He (K) : 1.13221
NMR Area : -9.62119
Polarization : 32.1309
General Run Info
Beam energy (MeV) : 2253.52
Beam Current : 179.91
Left arm angle : -0.179
Left arm momentum : 2.22804
Right arm angle : 0.197
Right arm momentum : 2.22797
Left septum current : 717.978
Right septum current : 718.057
Misc Epics Info
-----
Left Arm Q1 momentum : 2.22856
Left Arm Q1 power supply : 1138.47
Left Arm Q1 gauss meter : -0.09468
Left Arm Q2 gauss meter : 0.4804
Left Arm Q2 power supply current : 908.141
Left Arm Q2 momentum : 2.22837
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 758.898
Left Arm D1 momentum : 2.22804
Left Arm D1 NMR : 0.824399
Left Arm Q3 gauss meter : -0.54228
Left Arm Q3 power supply current : 1074.84
Left Arm Q3 momentum : 2.22777
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.22843
Right Arm Q1 power supply : 1131.42
Right Arm Q1 gauss meter : -0.0282
Right Arm Q2 power supply current : 910.27
Right Arm Q2 momentum : 2.22797
Right Arm Q2 gauss meter : 0.4794
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 779.334
Right Arm D1 momentum : 2.22797
Right Arm D1 NMR : 0.826772
Right Arm Q3 power supply current : 1072.76
Right Arm Q3 momentum : 2.22765
Right Arm Q3 gauss meter : 0.4755
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -59.6266
Wien BDL (Gcm) : -1721.1
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 184
Laser power Hall A : 0
Rotating waveplate : 7511
Fake Half-Wave Plate (8960=OUT) : 13056
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 717.978
Right Septum Magnet Current : 718.057
-----