    User name M. Yurov

    Log entry time 07:38:42 on March 30, 2012

    Entry number 368304

    This entry is a followup to: 368297

    Followups:

    keyword=[target] Main flow alarm. Missing events in PDP

    The problem with missing events got worsen. Every other event is missing.

    Got major alarm on main flow. Got minor alarm on the nose level. PID loop was not working properly.

    Polarization dropped from 21.5% to ~12%

    PDP stopped displaying Polarization value and Q-curves for about 5 min.

    It happened right after we were done with production plan for the shift.

    Polarization was 22% after PDP display got back.

    Stopped Run Valve manually to decrease nose level.

    Turned the microwave off in order to prepare for dilution runs