    User name kamyers

    Log entry time 13:58:15 on March 30, 2012

    Entry number 368388

    keyword=Bleed-through measurement - 0.5%

    Now that Hall C is back up to high current I did a bleed-through 
    measurement.  Note that the RHRS was at the elastic setting for this 
    measurement, the LHRS was at the 1.792 GeV setting
    
    T3 rates (you get the same answer using the T1 rates):
    
    Rate_Cosmic (fig1): ~14 Hz (this was taken with the slit closed)
    Rate_C+Cosmic (fig2): ~477 Hz (slit at 14, hall A laser off, hall c on)
    Rate_A+C+Cosmic (fig3): ~94 kHz
    
    This gives a bleed-through of 0.5%.  I'm not sure what is "too big", but I 
    definitely remember in the past seeing a negligible difference between 
    cosmic and cosmic+hallc.
    


    A copy of this log entry has been emailed to: kaylan



    Cosmic



    Hall C + Cosmic



    Hall A + Hall C + Cosmic