NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 07:59:30 on April 10, 2012
Entry number 372476
keyword=End_of_Run_4087
****************************
Run Number: 4087
End of Run Comment:
Run_type=Other,target_type=Home(no target, or empty),comment_text=slow raster calibration
PRESCALE FACTORS:ps1=0 ps2=0 ps3=1 ps4=3 ps5=0 ps6=0 ps7=20 ps8=0
EVENTS : 882953
TIME : 2.840 mins
DEAD TIME: 2.66%
TRIGGER RATES: PRES/REAL
T1:T1: 0.0/109.2 Hz T2:T2: 0.0/5.9 Hz T3:T3:116.5/116.5 Hz T4:T4:12.0/36.1 Hz T5:T5: 0.0/14829.6 Hz T6:T6: 0.0/5237.1 Hz T7:T7:5195.3/103906.1 Hz T8:T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 0/18603 T2:T2: 0/998 T3:T3: 19843/19843 T4:T4: 2049/6149 T5:T5: 0/2526588 T6:T6: 0/892272 T7:T7: 885150/17703009 T8:T8: 0/174464
AVERAGE CURRENT
BCM 1 : 0.0618 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -2.15264 seconds
APPROXIMATE BCM CHARGES (C)
BCM u1 : 10.53
BCM d1 : 10.52
****************************
End-of-run EPICS data for Run Number 4087 at Tue Apr 10 07:59:26 EDT 2012
Target Info
Target number in beam : 1
Target encoder position : -175
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 999
Magnetic Field (T) : 2.49865
Magnet Current : 60.882
VPT 3He (K) : 1.25338
VPT 4He (K) : 1.27775
NMR Area : 999
Polarization : 999
General Run Info
Beam energy (MeV) : 1712.61
Beam Current : 0.0524356
Beam Current (Hall C) : 0
Left arm angle : -0.179
Left arm momentum : 1.705
Right arm angle : 0.197
Right arm momentum : 1.70498
Left septum current : 0.0420966
Right septum current : 0
Misc Epics Info
-----
Left Arm Q1 momentum : 1.70522
Left Arm Q1 power supply : 871.115
Left Arm Q1 gauss meter : -0.07248
Left Arm Q2 gauss meter : 0.368
Left Arm Q2 power supply current : 695.004
Left Arm Q2 momentum : 1.70538
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 570.872
Left Arm D1 momentum : 1.705
Left Arm D1 NMR : 0.630976
Left Arm Q3 gauss meter : -0.41525
Left Arm Q3 power supply current : 822.686
Left Arm Q3 momentum : 1.70514
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.7049
Right Arm Q1 power supply : 865.614
Right Arm Q1 gauss meter : -0.021698
Right Arm Q2 power supply current : 696.686
Right Arm Q2 momentum : 1.7052
Right Arm Q2 gauss meter : 0.3668
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 586.967
Right Arm D1 momentum : 1.70498
Right Arm D1 NMR : 0.632697
Right Arm Q3 power supply current : 821.239
Right Arm Q3 momentum : 1.70535
Right Arm Q3 gauss meter : 0.3641
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 0
Left Arm Angle Vernier : 0
Left Arm Scattering Angle : -0.179
-----
Right Arm Angle Floor Angle : 0
Right Arm Angle Vernier : 0
Right Arm Scattering Angle : 0.197
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 88.7125
Wien BDL (First Solenoid) (Gcm) : 1239.7
Wien BDL (Second Solenoid) (Gcm) : 729.5
Wien angle (Horizontal) : -49.5997
Wien BDL (Gcm) : -1432.5
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 188
Laser power Hall A : 0
Rotating waveplate : 329
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 0
Right Septum Magnet Current : 0
-----