• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 02:04:32 on April 15, 2012

    Entry number 374679

    keyword=End_of_Run_4417
    ****************************
     Run Number: 4417
     End of Run Comment:
    Run_type=Production,target_type=NH3 top,comment_text=p0=1.0966
     
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=3   ps4=5   ps5=0   ps6=0   ps7=0   ps8=100   
    
    EVENTS   : 5202432      
    
    TIME     : 16.773 mins  
    
    DEAD TIME:   8.19%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1: 0.0/16345.1 Hz   T2:T2: 0.0/158.9 Hz   T3:T3:5585.2/16755.5 Hz   T4:T4:35.5/177.3 Hz   T5:T5: 0.0/23615.7 Hz   T6:T6: 0.0/24315.7 Hz   T7:T7: 0.0/103914.6 Hz   T8:T8:10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:      0/16449402  T2:T2:      0/159935   T3:T3:5620818/16862454  T4:T4:  35684/178421   T5:T5:      0/23766412  T6:T6:      0/24470845  T7:T7:      0/104577789  T8:T8:  10305/1030535  
    
    AVERAGE CURRENT
    BCM 1 : 0.0578 uA  
    
    Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -2.11910 seconds
    
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 57.88          
    BCM d1 : 58.37          
    
    
    ****************************
    End-of-run EPICS data for Run Number 4417 at Sun Apr 15 02:04:28 EDT 2012
    
    

    Target Info

    Target number in beam : 1 Target encoder position : 49120 uWave Frequency (Ghz) : 69975.8 RF Frequency (Mhz) : 106.5 Magnetic Field (T) : 2.49865 Magnet Current : 60.882 VPT 3He (K) : 1.15149 VPT 4He (K) : 1.13221 NMR Area : -9.14966 Polarization : 31.4772

    General Run Info

    Beam energy (MeV) : 1710.58 Beam Current : 0.0535691 Beam Current (Hall C) : 91.59 Left arm angle : -0.179 Left arm momentum : 1.09657 Right arm angle : 0.197 Right arm momentum : 1.09659 Left septum current : 344.476 Right septum current : 452.509

    Misc Epics Info

    ----- Left Arm Q1 momentum : 1.09667 Left Arm Q1 power supply : 560.235 Left Arm Q1 gauss meter : -0.04664 Left Arm Q2 gauss meter : 0.2369 Left Arm Q2 power supply current : 446.91 Left Arm Q2 momentum : 1.09661 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 363.435 Left Arm D1 momentum : 1.09657 Left Arm D1 NMR : 0.40596 Left Arm Q3 gauss meter : -0.26715 Left Arm Q3 power supply current : 529.067 Left Arm Q3 momentum : 1.09657 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 1.09639 Right Arm Q1 power supply : 556.657 Right Arm Q1 gauss meter : -0.014026 Right Arm Q2 power supply current : 448.162 Right Arm Q2 momentum : 1.09692 Right Arm Q2 gauss meter : 0.2355 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 374.71 Right Arm D1 momentum : 1.09659 Right Arm D1 NMR : 0.406932 Right Arm Q3 power supply current : 528.039 Right Arm Q3 momentum : 1.09651 Right Arm Q3 gauss meter : 0.2344 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 0 Left Arm Angle Vernier : 0 Left Arm Scattering Angle : -0.179 ----- Right Arm Angle Floor Angle : 0 Right Arm Angle Vernier : 0 Right Arm Scattering Angle : 0.197 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : 88.7125 Wien BDL (First Solenoid) (Gcm) : 1239.7 Wien BDL (Second Solenoid) (Gcm) : 729.5 Wien angle (Horizontal) : -49.5997 Wien BDL (Gcm) : -1432.5 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 212 Laser power Hall A : 0 Rotating waveplate : 329 Fake Half-Wave Plate (8960=OUT) : 13056 Beam Half-wave plate (off=out) : OUT ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 344.476 Right Septum Magnet Current : 452.509 -----