• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 19:19:43 on May 3, 2012

    Entry number 381985

    keyword=End_of_Run_5586
    ****************************
     Run Number: 5586
     End of Run Comment:
    Run_type=Optics,target_type=C12_40,comment_text=Delta Scan 1%, No LHe
     
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=1   ps4=0   ps5=0   ps6=0   ps7=0   ps8=0   
    
    EVENTS   : 1001859      
    
    TIME     : 18.298 mins  
    
    DEAD TIME:   5.58%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1: 0.0/1308.9 Hz   T2:T2: 0.0/16.0 Hz   T3:T3:966.5/966.5 Hz   T4:T4: 0.0/12.2 Hz   T5:T5: 0.0/1877.7 Hz   T6:T6: 0.0/5280.5 Hz   T7:T7: 0.0/103926.4 Hz   T8:T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:      0/1436976  T2:T2:      0/17534    T3:T3:1061147/1061147  T4:T4:      0/13367    T5:T5:      0/2061453  T6:T6:      0/5797330  T7:T7:      0/114097951  T8:T8:      0/1124221  
    
    AVERAGE CURRENT
    BCM 1 : 0.0441 uA  
    
    Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.10849 seconds
    
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 46.96          
    BCM d1 : 49.86          
    
    
    ****************************
    End-of-run EPICS data for Run Number 5586 at Thu May 3 19:19:38 EDT 2012
    
    

    Target Info

    Target number in beam : 6 Target encoder position : 12391 uWave Frequency (Ghz) : 0 RF Frequency (Mhz) : 999 Magnetic Field (T) : 999 Magnet Current : 999 VPT 3He (K) : 0 VPT 4He (K) : 1.47804 NMR Area : 999 Polarization : 999

    General Run Info

    Beam energy (MeV) : 2253.84 Beam Current : 0.0503183 Beam Current (Hall C) : 180.06 Left arm angle : -0.179 Left arm momentum : 0 Right arm angle : 0.197 Right arm momentum : 1.73478 Left septum current : 716.547 Right septum current : 724.514

    Misc Epics Info

    ----- Left Arm Q1 momentum : 2.22741 Left Arm Q1 power supply : 1137.83 Left Arm Q1 gauss meter : -0.09466 Left Arm Q2 gauss meter : 0.4803 Left Arm Q2 power supply current : 907.953 Left Arm Q2 momentum : 2.22791 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 758.431 Left Arm D1 momentum : 0 Left Arm D1 NMR : 0.851425 Left Arm Q3 gauss meter : -0.54239 Left Arm Q3 power supply current : 1074.96 Left Arm Q3 momentum : 2.22801 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 1.73499 Right Arm Q1 power supply : 880.888 Right Arm Q1 gauss meter : -0.022104 Right Arm Q2 power supply current : 708.711 Right Arm Q2 momentum : 1.73463 Right Arm Q2 gauss meter : 0.3735 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 597.321 Right Arm D1 momentum : 1.73477 Right Arm D1 NMR : 0.643755 Right Arm Q3 power supply current : 835.633 Right Arm Q3 momentum : 1.73524 Right Arm Q3 gauss meter : 0.3704 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 0 Left Arm Angle Vernier : 0 Left Arm Scattering Angle : -0.179 ----- Right Arm Angle Floor Angle : 0 Right Arm Angle Vernier : 0 Right Arm Scattering Angle : 0.197 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : -91.9471 Wien BDL (First Solenoid) (Gcm) : -1020.5 Wien BDL (Second Solenoid) (Gcm) : -1020.5 Wien angle (Horizontal) : -60.8504 Wien BDL (Gcm) : -1757.2 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 128 Laser power Hall A : 0 Rotating waveplate : 3496 Fake Half-Wave Plate (8960=OUT) : 8960 Beam Half-wave plate (off=out) : OUT ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 716.61 Right Septum Magnet Current : 724.514 -----