    User name a-onl

    Log entry time 04:02:37 on May 5, 2012

    Entry number 382400

    keyword=End_of_Run_24405
    ****************************
     Run Number: 24405
     End of Run Comment:
    Run_type=Other,target_type=Home(no target, or empty),comment_text=bpm noise check
     
    
    PRESCALE FACTORS:ps1=2   ps2=3   ps3=0   ps4=0   ps5=0   ps6=0   ps7=0   ps8=1   
    
    EVENTS   : 234906       
    
    TIME     : 3.797 mins  
    
    DEAD TIME:   0.10%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1: 7.3/14.7 Hz   T2:T2: 1.0/3.0  Hz   T3:T3: 0.0/15.3 Hz   T4:T4: 0.0/5.3  Hz   T5:T5: 0.0/0.0  Hz   T6:T6: 0.0/0.0  Hz   T7:T7: 0.0/103932.7 Hz   T8:T8:1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:   1671/3343     T2:T2:    227/681      T3:T3:      0/3487     T4:T4:      0/1218     T5:T5:      0/0        T6:T6:      0/0        T7:T7:      0/23676465  T8:T8: 233273/233273   
    
    AVERAGE CURRENT
    BCM 1 : -0.0000uA  
    
    Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.38175 seconds
    
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : -0.003979      
    BCM d1 : -0.002888      
    
    
    ****************************
    End-of-run EPICS data for Run Number 24405 at Sat May 5 04:02:33 EDT 2012
    
    

    Target Info

    Target number in beam : 1 Target encoder position : 49100 uWave Frequency (Ghz) : 0 RF Frequency (Mhz) : 999 Magnetic Field (T) : 999 Magnet Current : 999 VPT 3He (K) : 1.2365 VPT 4He (K) : 1.26218 NMR Area : 999 Polarization : 999

    General Run Info

    Beam energy (MeV) : 2252.94 Beam Current : -6.52114e-05 Beam Current (Hall C) : 0 Left arm angle : -0.179 Left arm momentum : 2.22792 Right arm angle : 0.197 Right arm momentum : 1.73476 Left septum current : 0 Right septum current : 0

    Misc Epics Info

    ----- Left Arm Q1 momentum : 2.22731 Left Arm Q1 power supply : 1137.88 Left Arm Q1 gauss meter : -0.09463 Left Arm Q2 gauss meter : 0.4802 Left Arm Q2 power supply current : 907.865 Left Arm Q2 momentum : 2.22769 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 758.288 Left Arm D1 momentum : 2.22792 Left Arm D1 NMR : 0.939002 Left Arm Q3 gauss meter : -0.54239 Left Arm Q3 power supply current : 1074.92 Left Arm Q3 momentum : 2.22792 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 1.73499 Right Arm Q1 power supply : 880.888 Right Arm Q1 gauss meter : -0.022075 Right Arm Q2 power supply current : 708.707 Right Arm Q2 momentum : 1.73462 Right Arm Q2 gauss meter : 0.3735 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 597.321 Right Arm D1 momentum : 1.73476 Right Arm D1 NMR : 0.64375 Right Arm Q3 power supply current : 835.63 Right Arm Q3 momentum : 1.73524 Right Arm Q3 gauss meter : 0.3704 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 0 Left Arm Angle Vernier : 0 Left Arm Scattering Angle : -0.179 ----- Right Arm Angle Floor Angle : 0 Right Arm Angle Vernier : 0 Right Arm Scattering Angle : 0.197 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : -91.9471 Wien BDL (First Solenoid) (Gcm) : -1020.5 Wien BDL (Second Solenoid) (Gcm) : -1020.5 Wien angle (Horizontal) : -60.2008 Wien BDL (Gcm) : -1738.4 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 140 Laser power Hall A : 0 Rotating waveplate : 329 Fake Half-Wave Plate (8960=OUT) : 8960 Beam Half-wave plate (off=out) : IN ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 0 Right Septum Magnet Current : 0 -----