    Per. HALOG #383470:

    RF-absorbant foam was added inside the BPM-b chassis. Simultaneous RF signals were injected into a and b receivers, and statistics collected (Fig. 1). -106 dBm is the nominal expected signal for an M15-style BPM for 50 nA of beam current (Figure 2).

    Receivers are performing identically in this configuration. When BPM sensor was re-connected, slightly different noise statistics were observed, but they do not affect the 50 nA resolution (~ 150 um).

    J. Musson x7441



    A copy of this log entry has been emailed to: musson, allison, colek, pzhu, cansomme, garza



    Figure 1

    BPM_Test.pdf