NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 10:39:25 on May 10, 2012
Entry number 383574
keyword=End_of_Run_5911
****************************
Run Number: 5911
End of Run Comment:
Run_type=Other,target_type=Home(no target, or empty),comment_text=BPM calibration, HARP scan
PRESCALE FACTORS:ps1=0 ps2=0 ps3=5 ps4=3 ps5=0 ps6=0 ps7=0 ps8=1
EVENTS : 257467
TIME : 3.824 mins
DEAD TIME: 1.19%
TRIGGER RATES: PRES/REAL
T1:T1: 0.0/350.7 Hz T2:T2: 0.0/13.8 Hz T3:T3:89.6/447.8 Hz T4:T4:22.1/66.3 Hz T5:T5: 0.0/20023.6 Hz T6:T6: 0.0/8134.0 Hz T7:T7: 0.0/103830.7 Hz T8:T8:1024.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 0/80468 T2:T2: 0/3167 T3:T3: 20552/102760 T4:T4: 5071/15215 T5:T5: 0/4594714 T6:T6: 0/1866474 T7:T7: 0/23825491 T8:T8: 234972/234972
AVERAGE CURRENT
BCM 1 : 0.1004 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -2.26359 seconds
APPROXIMATE BCM CHARGES (C)
BCM u1 : 22.35
BCM d1 : 23.73
****************************
End-of-run EPICS data for Run Number 5911 at Thu May 10 10:39:20 EDT 2012
Target Info
Target number in beam : 7
Target encoder position : -3
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 999
Magnetic Field (T) : 999
Magnet Current : 999
VPT 3He (K) : 1.29541
VPT 4He (K) : 1.3299
NMR Area : 999
Polarization : 999
General Run Info
Beam energy (MeV) : 2253.57
Beam Current : 0.0926517
Beam Current (Hall C) : 1.44
Left arm angle : 12.502
Left arm momentum : 2.25107
Right arm angle : 12.5005
Right arm momentum : 2.25106
Left septum current : 725.03
Right septum current : 866.917
Misc Epics Info
-----
Left Arm Q1 momentum : 2.25135
Left Arm Q1 power supply : 1150.11
Left Arm Q1 gauss meter : -0.09563
Left Arm Q2 gauss meter : 0.4853
Left Arm Q2 power supply current : 917.536
Left Arm Q2 momentum : 2.25142
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 767.444
Left Arm D1 momentum : 2.25107
Left Arm D1 NMR : 0.832917
Left Arm Q3 gauss meter : -0.54804
Left Arm Q3 power supply current : 1086.12
Left Arm Q3 momentum : 2.25115
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 2.25136
Right Arm Q1 power supply : 1143.06
Right Arm Q1 gauss meter : -0.02847
Right Arm Q2 power supply current : 919.781
Right Arm Q2 momentum : 2.25125
Right Arm Q2 gauss meter : 0.4848
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 789.136
Right Arm D1 momentum : 2.25106
Right Arm D1 NMR : 0.83534
Right Arm Q3 power supply current : 1084.28
Right Arm Q3 momentum : 2.25158
Right Arm Q3 gauss meter : 0.4805
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -91.9471
Wien BDL (First Solenoid) (Gcm) : -1020.5
Wien BDL (Second Solenoid) (Gcm) : -1020.5
Wien angle (Horizontal) : -60.2008
Wien BDL (Gcm) : -1738.4
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 210
Laser power Hall A : 0
Rotating waveplate : 329
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 725.093
Right Septum Magnet Current : 866.917
-----