User name R. Michaels
Log entry time 04:02:18 on May11,2012
Entry number 383881
keyword=reboot of bbts1 for 3rd arm
The third-arm DAQ froze up at about 03:30. I logged into
bbts1 via the portserver bbps1 (port 5) and found it was
constantly printing about a bad VME interrupt. I could not
type anything, and ctrl-X failed to cause a reboot. I logged
into the hareboot30 and power cycled the outlet for bbts1.
This worked. Started run 41948.
Reminder: the passwords are on a paper near the whiteboard
for hlauser.
A note about hareboot30: We could not login via the web from
adaq (only tried one adaq computer, though), so we did it from
the target computer. From adaq the error said "URL blocked
from this VLAN". I was too tired to figure that one out,
so I went to the target computer.