NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 11:05:32 on May 11, 2012
Entry number 383952
keyword=End_of_Run_24651
****************************
Run Number: 24651
End of Run Comment:
Run_type=Production,target_type=NH3 top,comment_text=Production - top target
junk
PRESCALE FACTORS:can't read "psfacline": no such variable
while executing
"$w insert end "$psfacline..."
(procedure "halla_scaler_process" line 185)
invoked from within
"halla_scaler_process .mid.tex scalerinfo "
****************************
End-of-run EPICS data for Run Number 24651 at Fri May 11 11:05:28 EDT 2012
Target Info
Target number in beam : 1
Target encoder position : 47553
uWave Frequency (Ghz) : 140154
RF Frequency (Mhz) : 213
Magnetic Field (T) : 5.0247
Magnet Current : 121.819
VPT 3He (K) : 1.03286
VPT 4He (K) : 0
NMR Area : -45.1553
Polarization : 72.0838
General Run Info
Beam energy (MeV) : 2253.68
Beam Current : 0.0440166
Beam Current (Hall C) : 176.49
Left arm angle : 12.502
Left arm momentum : 1.9267
Right arm angle : 12.5005
Right arm momentum : 1.92666
Left septum current : 610.864
Right septum current : 810.664
Misc Epics Info
-----
Left Arm Q1 momentum : 1.92633
Left Arm Q1 power supply : 984.07
Left Arm Q1 gauss meter : -0.0819
Left Arm Q2 gauss meter : 0.4155
Left Arm Q2 power supply current : 785.022
Left Arm Q2 momentum : 1.92626
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 649.196
Left Arm D1 momentum : 1.9267
Left Arm D1 NMR : 0.71296
Left Arm Q3 gauss meter : -0.46921
Left Arm Q3 power supply current : 929.651
Left Arm Q3 momentum : 1.92684
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.92643
Right Arm Q1 power supply : 978.088
Right Arm Q1 gauss meter : -0.02441
Right Arm Q2 power supply current : 787.109
Right Arm Q2 momentum : 1.92652
Right Arm Q2 gauss meter : 0.4149
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 667.464
Right Arm D1 momentum : 1.92666
Right Arm D1 NMR : 0.714961
Right Arm Q3 power supply current : 928.078
Right Arm Q3 momentum : 1.92721
Right Arm Q3 gauss meter : 0.4114
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -91.9471
Wien BDL (First Solenoid) (Gcm) : -1020.5
Wien BDL (Second Solenoid) (Gcm) : -1020.5
Wien angle (Horizontal) : -60.2008
Wien BDL (Gcm) : -1738.4
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 182
Laser power Hall A : 0
Rotating waveplate : 3496
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 610.864
Right Septum Magnet Current : 810.664
-----