NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 18:58:19 on May 11, 2012
Entry number 384068
keyword=End_of_Run_24671
****************************
Run Number: 24671
End of Run Comment:
Run_type=Other,target_type=Home(no target, or empty),comment_text=BCM calibration run, ps8=5
PRESCALE FACTORS:ps1=1 ps2=1 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=50
EVENTS : 136251
TIME : 32.672 mins
DEAD TIME: 4.38%
TRIGGER RATES: PRES/REAL
T1:T1:48.0/48.0 Hz T2:T2: 4.2/4.2 Hz T3:T3: 0.0/55.5 Hz T4:T4: 0.0/15.3 Hz T5:T5: 0.0/0.0 Hz T6:T6: 0.0/0.0 Hz T7:T7: 0.0/103915.4 Hz T8:T8:20.5/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 94117/94117 T2:T2: 8242/8242 T3:T3: 0/108849 T4:T4: 0/30054 T5:T5: 0/0 T6:T6: 0/0 T7:T7: 0/203705406 T8:T8: 40146/2007348
AVERAGE CURRENT
BCM 1 : 0.0120 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = 1.58660 seconds
APPROXIMATE BCM CHARGES (C)
BCM u1 : 22.85
BCM d1 : 24.22
****************************
End-of-run EPICS data for Run Number 24671 at Fri May 11 18:58:15 EDT 2012
Target Info
Target number in beam : 1
Target encoder position : 47553
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 213
Magnetic Field (T) : 5.0247
Magnet Current : 121.819
VPT 3He (K) : 1.01031
VPT 4He (K) : 0
NMR Area : -43.0611
Polarization : 68.7406
General Run Info
Beam energy (MeV) : 2253.48
Beam Current : -0.00022045
Beam Current (Hall C) : 110.34
Left arm angle : 12.502
Left arm momentum : 1.81107
Right arm angle : 12.5005
Right arm momentum : 1.81105
Left septum current : 572.493
Right septum current : 758.464
Misc Epics Info
-----
Left Arm Q1 momentum : 1.81133
Left Arm Q1 power supply : 925.322
Left Arm Q1 gauss meter : -0.07701
Left Arm Q2 gauss meter : 0.3905
Left Arm Q2 power supply current : 737.903
Left Arm Q2 momentum : 1.81064
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 607.894
Left Arm D1 momentum : 1.81107
Left Arm D1 NMR : 0.670202
Left Arm Q3 gauss meter : -0.44106
Left Arm Q3 power supply current : 873.848
Left Arm Q3 momentum : 1.81118
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.81093
Right Arm Q1 power supply : 919.448
Right Arm Q1 gauss meter : -0.023
Right Arm Q2 power supply current : 739.879
Right Arm Q2 momentum : 1.81092
Right Arm Q2 gauss meter : 0.3898
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 625.141
Right Arm D1 momentum : 1.81105
Right Arm D1 NMR : 0.672059
Right Arm Q3 power supply current : 872.096
Right Arm Q3 momentum : 1.81096
Right Arm Q3 gauss meter : 0.3868
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -91.9471
Wien BDL (First Solenoid) (Gcm) : -1020.5
Wien BDL (Second Solenoid) (Gcm) : -1020.5
Wien angle (Horizontal) : -60.2008
Wien BDL (Gcm) : -1738.4
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 100
Laser power Hall A : 0
Rotating waveplate : 3496
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 572.219
Right Septum Magnet Current : 758.464
-----