NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 18:59:58 on May 11, 2012
Entry number 384069
keyword=End_of_Run_5987
****************************
Run Number: 5987
End of Run Comment:
Run_type=Other,target_type=NH3 top,comment_text=DAQ test
PRESCALE FACTORS:ps1=1 ps2=2 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=50
EVENTS : 358
TIME : 0.291 mins
DEAD TIME: 43.45%
TRIGGER RATES: PRES/REAL
T1:T1:14.6/14.6 Hz T2:T2: 1.1/2.2 Hz T3:T3: 0.0/15.2 Hz T4:T4: 0.0/5.9 Hz T5:T5: 0.0/373.7 Hz T6:T6: 0.0/4240.6 Hz T7:T7: 0.0/103933.3 Hz T8:T8:20.5/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 256/256 T2:T2: 19/38 T3:T3: 0/266 T4:T4: 0/104 T5:T5: 0/6535 T6:T6: 0/74153 T7:T7: 0/1817411 T8:T8: 358/17906
AVERAGE CURRENT
BCM 1 : -0.0000uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -3.48747 seconds
APPROXIMATE BCM CHARGES (C)
BCM u1 : -0.0002659
BCM d1 : -0.0003153
****************************
End-of-run EPICS data for Run Number 5987 at Fri May 11 18:59:52 EDT 2012
Target Info
Target number in beam : 1
Target encoder position : 47553
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 213
Magnetic Field (T) : 5.0247
Magnet Current : 121.819
VPT 3He (K) : 1.01054
VPT 4He (K) : 0
NMR Area : -43.8773
Polarization : 70.0436
General Run Info
Beam energy (MeV) : 2253.29
Beam Current : -9.88511e-05
Beam Current (Hall C) : 108.9
Left arm angle : 12.502
Left arm momentum : 1.81107
Right arm angle : 12.5005
Right arm momentum : 1.81105
Left septum current : 572.408
Right septum current : 758.448
Misc Epics Info
-----
Left Arm Q1 momentum : 1.81133
Left Arm Q1 power supply : 925.322
Left Arm Q1 gauss meter : -0.07704
Left Arm Q2 gauss meter : 0.3906
Left Arm Q2 power supply current : 737.905
Left Arm Q2 momentum : 1.81065
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 607.892
Left Arm D1 momentum : 1.81107
Left Arm D1 NMR : 0.670202
Left Arm Q3 gauss meter : -0.44103
Left Arm Q3 power supply current : 873.848
Left Arm Q3 momentum : 1.81118
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.81104
Right Arm Q1 power supply : 919.501
Right Arm Q1 gauss meter : -0.02295
Right Arm Q2 power supply current : 739.88
Right Arm Q2 momentum : 1.81092
Right Arm Q2 gauss meter : 0.3898
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 625.142
Right Arm D1 momentum : 1.81105
Right Arm D1 NMR : 0.672059
Right Arm Q3 power supply current : 872.097
Right Arm Q3 momentum : 1.81096
Right Arm Q3 gauss meter : 0.3867
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -91.9471
Wien BDL (First Solenoid) (Gcm) : -1020.5
Wien BDL (Second Solenoid) (Gcm) : -1020.5
Wien angle (Horizontal) : -60.2008
Wien BDL (Gcm) : -1738.4
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 100
Laser power Hall A : 0
Rotating waveplate : 3496
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 572.493
Right Septum Magnet Current : 758.464
-----