• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 19:09:22 on May 11, 2012

    Entry number 384073

    keyword=End_of_Run_5990
    ****************************
     Run Number: 5990
     End of Run Comment:
    Run_type=Other,target_type=NH3 top,comment_text=DAQ test
     
    
    PRESCALE FACTORS:can't read "psfacline": no such variable
        while executing
    "$w insert end "$psfacline..."
        (procedure "halla_scaler_process" line 195)
        invoked from within
    "halla_scaler_process .mid.tex scalerinfo "
    
    ****************************
    End-of-run EPICS data for Run Number 5990 at Fri May 11 19:09:10 EDT 2012
    
    

    Target Info

    Target number in beam : 1 Target encoder position : 47553 uWave Frequency (Ghz) : 140174 RF Frequency (Mhz) : 213 Magnetic Field (T) : 5.0247 Magnet Current : 121.819 VPT 3He (K) : 1.01108 VPT 4He (K) : 0 NMR Area : -48.4669 Polarization : 77.3702

    General Run Info

    Beam energy (MeV) : 2253.49 Beam Current : -0.000213971 Beam Current (Hall C) : 110.52 Left arm angle : 12.502 Left arm momentum : 1.81107 Right arm angle : 12.5005 Right arm momentum : 1.81105 Left septum current : 572.156 Right septum current : 758.464

    Misc Epics Info

    ----- Left Arm Q1 momentum : 1.81133 Left Arm Q1 power supply : 925.322 Left Arm Q1 gauss meter : -0.07701 Left Arm Q2 gauss meter : 0.3905 Left Arm Q2 power supply current : 737.904 Left Arm Q2 momentum : 1.81065 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 607.894 Left Arm D1 momentum : 1.81107 Left Arm D1 NMR : 0.670201 Left Arm Q3 gauss meter : -0.44104 Left Arm Q3 power supply current : 873.851 Left Arm Q3 momentum : 1.81119 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 1.81104 Right Arm Q1 power supply : 919.448 Right Arm Q1 gauss meter : -0.02292 Right Arm Q2 power supply current : 739.88 Right Arm Q2 momentum : 1.81092 Right Arm Q2 gauss meter : 0.3898 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 625.143 Right Arm D1 momentum : 1.81105 Right Arm D1 NMR : 0.672059 Right Arm Q3 power supply current : 872.096 Right Arm Q3 momentum : 1.81096 Right Arm Q3 gauss meter : 0.3867 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 12.5 Left Arm Angle Vernier : 31.4 Left Arm Scattering Angle : HacL_alignAGL --- Invalid channel name ----- Right Arm Angle Floor Angle : 12.5 Right Arm Angle Vernier : -34.1 Right Arm Scattering Angle : 12.5005 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : -91.9471 Wien BDL (First Solenoid) (Gcm) : -1020.5 Wien BDL (Second Solenoid) (Gcm) : -1020.5 Wien angle (Horizontal) : -60.2008 Wien BDL (Gcm) : -1738.4 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 100 Laser power Hall A : 0 Rotating waveplate : 3496 Fake Half-Wave Plate (8960=OUT) : 8960 Beam Half-wave plate (off=out) : OUT ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 572.156 Right Septum Magnet Current : 758.448 -----