NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 18:23:49 on May 12, 2012
Entry number 384434
keyword=End_of_Run_24700
****************************
Run Number: 24700
End of Run Comment:
Run_type=Other,target_type=Home(no target, or empty),comment_text=BCM calibration
PRESCALE FACTORS:ps1=1 ps2=1 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=50
EVENTS : 99806
TIME : 36.497 mins
DEAD TIME: 0.63%
TRIGGER RATES: PRES/REAL
T1:T1:20.8/20.8 Hz T2:T2: 4.5/4.5 Hz T3:T3: 0.0/54.8 Hz T4:T4: 0.0/23.8 Hz T5:T5: 0.0/0.0 Hz T6:T6: 0.0/0.0 Hz T7:T7: 0.0/103902.2 Hz T8:T8:20.5/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 45641/45641 T2:T2: 9959/9959 T3:T3: 0/119904 T4:T4: 0/52086 T5:T5: 0/0 T6:T6: 0/0 T7:T7: 0/227528992 T8:T8: 44847/2242394
AVERAGE CURRENT
BCM 1 : 0.0200 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = 4.20349 seconds
APPROXIMATE BCM CHARGES (C)
BCM u1 : 42.59
BCM d1 : 45.13
****************************
End-of-run EPICS data for Run Number 24700 at Sat May 12 18:23:46 EDT 2012
Target Info
Target number in beam : 1
Target encoder position : 47553
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 213
Magnetic Field (T) : 5.0247
Magnet Current : 121.819
VPT 3He (K) : 1.53226
VPT 4He (K) : 0
NMR Area : 0.0027116
Polarization : -0.00504944
General Run Info
Beam energy (MeV) : 2253.57
Beam Current : -3.62592e-05
Beam Current (Hall C) : 111.06
Left arm angle : 12.502
Left arm momentum : 2.22796
Right arm angle : 12.5005
Right arm momentum : 1.41401
Left septum current : 716.61
Right septum current : 585.539
Misc Epics Info
-----
Left Arm Q1 momentum : 2.22731
Left Arm Q1 power supply : 1137.88
Left Arm Q1 gauss meter : -0.09465
Left Arm Q2 gauss meter : 0.4803
Left Arm Q2 power supply current : 908.105
Left Arm Q2 momentum : 2.22828
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 758.955
Left Arm D1 momentum : 2.22796
Left Arm D1 NMR : 0.824372
Left Arm Q3 gauss meter : -0.54237
Left Arm Q3 power supply current : 1074.93
Left Arm Q3 momentum : 2.22795
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.41374
Right Arm Q1 power supply : 717.784
Right Arm Q1 gauss meter : -0.017989
Right Arm Q2 power supply current : 577.893
Right Arm Q2 momentum : 1.41445
Right Arm Q2 gauss meter : 0.3043
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 484.135
Right Arm D1 momentum : 1.41401
Right Arm D1 NMR : 0.524722
Right Arm Q3 power supply current : 681.13
Right Arm Q3 momentum : 1.41441
Right Arm Q3 gauss meter : 0.3022
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -91.9471
Wien BDL (First Solenoid) (Gcm) : -1020.5
Wien BDL (Second Solenoid) (Gcm) : -1020.5
Wien angle (Horizontal) : -60.2008
Wien BDL (Gcm) : -1738.4
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 100
Laser power Hall A : 0
Rotating waveplate : 7511
Fake Half-Wave Plate (8960=OUT) : 13056
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 716.61
Right Septum Magnet Current : 585.555
-----