• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name a-onl

    Log entry time 14:10:32 on May 14, 2012

    Entry number 384882

    keyword=End_of_Run_6101
    ****************************
     Run Number: 6101
     End of Run Comment:
    Run_type=Other,target_type=Home(no target, or empty),comment_text=bcm test
     
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=8   ps4=5   ps5=0   ps6=0   ps7=0   ps8=50   
    
    EVENTS   : 11277        
    
    TIME     : 7.990 mins  
    
    DEAD TIME:   0.11%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1: 0.0/14.9 Hz   T2:T2: 0.0/3.0  Hz   T3:T3: 1.9/15.2 Hz   T4:T4: 1.2/5.8  Hz   T5:T5: 0.0/581.1 Hz   T6:T6: 0.0/4543.5 Hz   T7:T7: 0.0/103891.8 Hz   T8:T8:20.5/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:      0/7124     T2:T2:      0/1457     T3:T3:    913/7310     T4:T4:    556/2784     T5:T5:      0/278591   T6:T6:      0/2178230  T7:T7:      0/49807797  T8:T8:   9818/490926   
    
    AVERAGE CURRENT
    BCM 1 : -0.0009uA  
    
    Test of Helicity gates
    Time diff of helicity to nonhelicity times  =        -1.67775 seconds
    
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : -0.4413        
    BCM d1 : -0.4278        
    
    
    ****************************
    End-of-run EPICS data for Run Number 6101 at Mon May 14 14:10:27 EDT 2012
    
    

    Target Info

    Target number in beam : 1 Target encoder position : 49047 uWave Frequency (Ghz) : 0 RF Frequency (Mhz) : 999 Magnetic Field (T) : 0 Magnet Current : 100 VPT 3He (K) : 999 VPT 4He (K) : 999 NMR Area : 999 Polarization : 999

    General Run Info

    Beam energy (MeV) : 3352.4 Beam Current : 0.0280834 Beam Current (Hall C) : 45.51 Left arm angle : 12.502 Left arm momentum : 2.22795 Right arm angle : 12.5005 Right arm momentum : 1.01572 Left septum current : 99.2848 Right septum current : 99.9931

    Misc Epics Info

    ----- Left Arm Q1 momentum : 2.22731 Left Arm Q1 power supply : 1137.83 Left Arm Q1 gauss meter : -0.09462 Left Arm Q2 gauss meter : 0.4804 Left Arm Q2 power supply current : 908.101 Left Arm Q2 momentum : 2.22827 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 758.903 Left Arm D1 momentum : 2.22795 Left Arm D1 NMR : 0.824367 Left Arm Q3 gauss meter : -0.54234 Left Arm Q3 power supply current : 1074.88 Left Arm Q3 momentum : 2.22785 Left Arm Q3 power supply polarity : disabled ----- Right Arm Q1 momentum : 1.01571 Right Arm Q1 power supply : 515.694 Right Arm Q1 gauss meter : -0.013008 Right Arm Q2 power supply current : 414.981 Right Arm Q2 momentum : 1.0157 Right Arm Q2 gauss meter : 0.2181 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 346.912 Right Arm D1 momentum : 1.01571 Right Arm D1 NMR : 0.37692 Right Arm Q3 power supply current : 489.132 Right Arm Q3 momentum : 1.01571 Right Arm Q3 gauss meter : 0.217 Right Arm Q3 power supply polarity : disabled ----- Left Arm Angle Floor Angle : 12.5 Left Arm Angle Vernier : 31.4 Left Arm Scattering Angle : 12.502 ----- Right Arm Angle Floor Angle : 12.5 Right Arm Angle Vernier : -34.1 Right Arm Scattering Angle : 12.5005 ----- Wien angle (Vertical) : 89.9999 Wien Vertical BDL (Gcm) : 2649.6 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : -91.9471 Wien BDL (First Solenoid) (Gcm) : -1020.5 Wien BDL (Second Solenoid) (Gcm) : -1020.5 Wien angle (Horizontal) : -60.2008 Wien BDL (Gcm) : -1738.4 Wien HV Polarity (Horizontal) : NEGATIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 140 Laser power Hall A : 0 Rotating waveplate : 329 Fake Half-Wave Plate (8960=OUT) : 8960 Beam Half-wave plate (off=out) : IN ----- Helicity Delay Set : 8 windows Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 70 Helicity Stable Read : 971.65 Helicity Delay Read : 8 windows Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 960.015 Left Septum Magnet Current : 99.2427 Right Septum Magnet Current : 99.9931 -----