NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 10:36:01 on May 17, 2012
Entry number 385610
keyword=End_of_Run_6197
****************************
Run Number: 6197
End of Run Comment:
Run_type=Dilution,target_type=Home(no target, or empty),comment_text=p=2.3422 GeV
PRESCALE FACTORS:ps1=0 ps2=0 ps3=1 ps4=2 ps5=0 ps6=0 ps7=0 ps8=50
EVENTS : 559108
TIME : 6.166 mins
DEAD TIME: 7.41%
TRIGGER RATES: PRES/REAL
T1:T1: 0.0/750.6 Hz T2:T2: 0.0/38.6 Hz T3:T3:1544.9/1544.9 Hz T4:T4:67.0/134.0 Hz T5:T5: 0.0/34938.8 Hz T6:T6: 0.0/11806.3 Hz T7:T7: 0.0/103885.7 Hz T8:T8:20.5/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 0/277681 T2:T2: 0/14266 T3:T3: 571519/571519 T4:T4: 24794/49589 T5:T5: 0/12925204 T6:T6: 0/4367607 T7:T7: 0/38431320 T8:T8: 7576/378817
AVERAGE CURRENT
BCM 1 : 0.1100 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -2.39821 seconds
APPROXIMATE BCM CHARGES (C)
BCM u1 : 39.44
BCM d1 : 41.94
****************************
End-of-run EPICS data for Run Number 6197 at Thu May 17 10:35:56 EDT 2012
Target Info
Target number in beam : 7
Target encoder position : -43
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 999
Magnetic Field (T) : 0
Magnet Current : 121.814
VPT 3He (K) : 999
VPT 4He (K) : 0
NMR Area : 999
Polarization : 999
General Run Info
Beam energy (MeV) : 3350.08
Beam Current : 103.247
Beam Current (Hall C) : 180.63
Left arm angle : 12.502
Left arm momentum : 2.34218
Right arm angle : 12.5005
Right arm momentum : 1.94535
Left septum current : 759.275
Right septum current : 939.096
Misc Epics Info
-----
Left Arm Q1 momentum : 2.34189
Left Arm Q1 power supply : 1196.36
Left Arm Q1 gauss meter : -0.09958
Left Arm Q2 gauss meter : 0.5047
Left Arm Q2 power supply current : 954.367
Left Arm Q2 momentum : 2.3418
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 799.422
Left Arm D1 momentum : 2.34218
Left Arm D1 NMR : 0.866611
Left Arm Q3 gauss meter : -0.57018
Left Arm Q3 power supply current : 1130.13
Left Arm Q3 momentum : 2.34237
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.94537
Right Arm Q1 power supply : 987.701
Right Arm Q1 gauss meter : -0.024707
Right Arm Q2 power supply current : 794.767
Right Arm Q2 momentum : 1.94526
Right Arm Q2 gauss meter : 0.4188
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 674.122
Right Arm D1 momentum : 1.94535
Right Arm D1 NMR : 0.721897
Right Arm Q3 power supply current : 936.786
Right Arm Q3 momentum : 1.94529
Right Arm Q3 gauss meter : 0.4153
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -91.9471
Wien BDL (First Solenoid) (Gcm) : -1020.5
Wien BDL (Second Solenoid) (Gcm) : -1020.5
Wien angle (Horizontal) : -60.2008
Wien BDL (Gcm) : -1738.4
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 250
Laser power Hall A : 0
Rotating waveplate : 329
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 759.233
Right Septum Magnet Current : 939.096
-----