NEXT
Make New Entry,
Make Followup Entry
User name a-onl
Log entry time 11:26:04 on May 17, 2012
Entry number 385639
keyword=End_of_Run_6204
****************************
Run Number: 6204
End of Run Comment:
Run_type=Dilution,target_type=NH3 bottom,comment_text=p=2.2017 GeV
PRESCALE FACTORS:ps1=0 ps2=0 ps3=1 ps4=2 ps5=0 ps6=0 ps7=0 ps8=50
EVENTS : 1025926
TIME : 5.900 mins
DEAD TIME: 15.14%
TRIGGER RATES: PRES/REAL
T1:T1: 0.0/1891.4 Hz T2:T2: 0.0/66.0 Hz T3:T3:3327.5/3327.5 Hz T4:T4:67.3/134.5 Hz T5:T5: 0.0/33001.4 Hz T6:T6: 0.0/12823.1 Hz T7:T7: 0.0/103886.0 Hz T8:T8:20.5/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 0/669602 T2:T2: 0/23376 T3:T3:1178020/1178020 T4:T4: 23817/47634 T5:T5: 0/11683351 T6:T6: 0/4539712 T7:T7: 0/36778385 T8:T8: 7250/362523
AVERAGE CURRENT
BCM 1 : 0.0993 uA
Test of Helicity gates
Time diff of helicity to nonhelicity times = -1.47612 seconds
APPROXIMATE BCM CHARGES (C)
BCM u1 : 34.08
BCM d1 : 36.25
****************************
End-of-run EPICS data for Run Number 6204 at Thu May 17 11:26:01 EDT 2012
Target Info
Target number in beam : 4
Target encoder position : 31429
uWave Frequency (Ghz) : 0
RF Frequency (Mhz) : 999
Magnetic Field (T) : 0
Magnet Current : 121.814
VPT 3He (K) : 999
VPT 4He (K) : 999
NMR Area : 999
Polarization : 999
General Run Info
Beam energy (MeV) : 3350.12
Beam Current : 96.3778
Beam Current (Hall C) : 178.83
Left arm angle : 12.502
Left arm momentum : 2.20166
Right arm angle : 12.5005
Right arm momentum : 1.94535
Left septum current : 659.843
Right septum current : 939.096
Misc Epics Info
-----
Left Arm Q1 momentum : 2.20117
Left Arm Q1 power supply : 1124.48
Left Arm Q1 gauss meter : -0.09358
Left Arm Q2 gauss meter : 0.4745
Left Arm Q2 power supply current : 897.117
Left Arm Q2 momentum : 2.20132
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 748.066
Left Arm D1 momentum : 2.20166
Left Arm D1 NMR : 0.814644
Left Arm Q3 gauss meter : -0.53607
Left Arm Q3 power supply current : 1062.35
Left Arm Q3 momentum : 2.20188
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 1.94537
Right Arm Q1 power supply : 987.701
Right Arm Q1 gauss meter : -0.024691
Right Arm Q2 power supply current : 794.778
Right Arm Q2 momentum : 1.94529
Right Arm Q2 gauss meter : 0.4188
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 674.122
Right Arm D1 momentum : 1.94535
Right Arm D1 NMR : 0.721895
Right Arm Q3 power supply current : 936.798
Right Arm Q3 momentum : 1.94532
Right Arm Q3 gauss meter : 0.4153
Right Arm Q3 power supply polarity : disabled
-----
Left Arm Angle Floor Angle : 12.5
Left Arm Angle Vernier : 31.4
Left Arm Scattering Angle : 12.502
-----
Right Arm Angle Floor Angle : 12.5
Right Arm Angle Vernier : -34.1
Right Arm Scattering Angle : 12.5005
-----
Wien angle (Vertical) : 89.9999
Wien Vertical BDL (Gcm) : 2649.6
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -91.9471
Wien BDL (First Solenoid) (Gcm) : -1020.5
Wien BDL (Second Solenoid) (Gcm) : -1020.5
Wien angle (Horizontal) : -60.2008
Wien BDL (Gcm) : -1738.4
Wien HV Polarity (Horizontal) : NEGATIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 250
Laser power Hall A : 0
Rotating waveplate : 329
Fake Half-Wave Plate (8960=OUT) : 8960
Beam Half-wave plate (off=out) : IN
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 70
Helicity Stable Read : 971.65
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 960.015
Left Septum Magnet Current : 659.843
Right Septum Magnet Current : 939.096
-----