• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 12:05:32 on November28,2012

    Entry number 385739

    keyword=status of L-HRS DAQ

    Run the DAQ on the "adaq" account on adaql2.

    The "test1" config is working; it is the TS11 crate only.
    But this shows that the set up of adaq account is ok.

    The "LHRS" config downloads and prestarts, but there are
    no events. It is as if the RS485 cable is bad or the jumpers
    not set correctly, or something.

    What I think is the setup is below. (But I could be wrong
    somehow). The HW roc numbers come from the jumper on the
    TS RS485 line.

    ROC4 ... top crate ... HW roc 4 ... hallasfi4 ... sfi4.crl
    Has 9 TDCs in slots 3 - 11.

    ROC5 ... middle crate ... HW roc 6 ... hallasfi5 .... sfi5.crl
    Has 9 TDCs in slots 16 - 24.

    ROC3 ... bottom crate ... HW roc 5 ... hallasfi3 .... sfi3.crl
    Has 8 ADCs in slots 16 - 23.

    All the ADCs and TDCs were tested with the usual Fastbus test
    codes. They all work, except that slot 19 in ROC5 (middle
    crate) has a strange response; it reports one header word.
    We might want to swap that TDC. But I don't think that's why
    I get no events.

    Will keep working ....