Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name R. Michaels
Log entry time 04:39:31 on March27,2014
Entry number 387716
Followups:
keyword=BPM/raster check, part 2
Information about quads downstream of raster.
They are at "normal" settings.
MQK1H01 at 9600A
MQA1H04 at -2400 A
Moving beam with unrastered 2 uA beam and no target.
Next runs are 1259 / 20273
Asked for 2,-2
BPM4A at 0.66, -2
BPM4D at 2, -2
Next runs are 1260 / 20274
04:00 ask for -2, +2
BPM4A at -1.7, 0.3
BPM4D at -1.9, 2
Next runs are 1261 / 20275
04:15 ask for -2, -2
BPM4A at -1.7, -2
BPM4D at -2, -2.1
Runs 1262 / 20277
runs at nominal (0,0)
still 2 uA, raster off
BPM4A -0.5, -0.9
BPM4D 0.14, -0.13
Some representative prelim. plots are shown in fig 1 and 2.
Good news: Beam moves around and the "out of the box" old calibration has
the right scale (of order 2 mm).
Slightly bad news: Sometimes "plus" direction is "minus", and in fig 2 it seems
X and Y are swapped. I've only shown BPM4A here. The other BPM also moves
and has similar confusions.
FIGURE 1
FIGURE 2