• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name R. Michaels

    Log entry time 04:39:31 on March27,2014

    Entry number 387716

    Followups:

    keyword=BPM/raster check, part 2

    Information about quads downstream of raster.
    They are at "normal" settings.
    MQK1H01 at 9600A
    MQA1H04 at -2400 A

    Moving beam with unrastered 2 uA beam and no target.

    Next runs are 1259 / 20273
    Asked for 2,-2
    BPM4A at 0.66, -2
    BPM4D at 2, -2

    Next runs are 1260 / 20274
    04:00 ask for -2, +2
    BPM4A at -1.7, 0.3
    BPM4D at -1.9, 2

    Next runs are 1261 / 20275
    04:15 ask for -2, -2
    BPM4A at -1.7, -2
    BPM4D at -2, -2.1

    Runs 1262 / 20277
    runs at nominal (0,0)
    still 2 uA, raster off
    BPM4A -0.5, -0.9
    BPM4D 0.14, -0.13

    Some representative prelim. plots are shown in fig 1 and 2.

    Good news: Beam moves around and the "out of the box" old calibration has
    the right scale (of order 2 mm).

    Slightly bad news: Sometimes "plus" direction is "minus", and in fig 2 it seems
    X and Y are swapped. I've only shown BPM4A here. The other BPM also moves
    and has similar confusions.



    FIGURE 1