NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 16:21:47 on March 27, 2014
Entry number 387816
keyword=Start_Run_1277,Run_type=Cosmics,target_type=Home(no target, or empty),comment_text=T3 trigger
Run Timestamp: Thu Mar 27 16:21:36 EDT 2014
Beginning-of-run EPICS data for Run Number 1277 at Thu Mar 27 16:21:42 EDT 2014
Shift Worker Info
Run_type=Cosmics
target_type=Home(no target, or empty)
comment_text=T3 trigger
Prescale Values
;This file is automatically generated from L-HRS prescales GUI.
;To generate this file, type "prescaleL" without quotes on adaq@adaq1
;Input the desired prescales and Save.
;T1 = L-arm s0 && S2m trigger
;T2 = L-arm s0 && GC trigger
;T3 = L-arm s2 && GC trigger
;T4 = L-arm s0 && Shower trigger
;T5 = L-arm s2m && Shower trigger
;T6 = L-arm GC && Shower trigger
;T7 = L-arm EDTM trigger
;T8 = 103.7 KHz pulser
ps1=0,ps2=0,ps3=1,ps4=0,ps5=0,ps6=0,ps7=0,ps8=0
General Run Info
Misc Epics Info
Left Arm Q1 momentum : 3.00074
Left Arm Q1 power supply : 2257.55
Left Arm Q1 gauss meter : -0.18785
Left Arm Q2 power supply current : 1291.49
Left Arm Q2 momentum : 2.99929
Left Arm Q2 gauss meter : 0.6822
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1047.36
Left Arm D1 momentum : 3.00002
Left Arm D1 NMR : 1.11085
Left Arm Q3 power supply current : 1194.25
Left Arm Q3 momentum : 2.99974
Left Arm Q3 gauss meter : -0.60225
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -1.0711
Target Info
-----
Target : Empty 2
fan frequency loop 1 : 62.5
fan frequency loop 2 : 104
Encoder position : 1.74519e+07
Target type : 1.74519e+07
temperature loop 1(1) : 19.027
temperature loop 1(2) : 19.154
temperature loop 1(3) : 18.877
Heat exchange loop 1 D2 : 18.998
temperature loop 2(1) : 99.967
temperature loop 2(2) : 102.36
temperature loop 2(3) : 99.614
Heat exchange loop 2 LH2 : 100.73
pressure loop He : 0
pressure loop H2 before : 27.8676
pressure loop H2 return : 27.5288
pressure loop D2 before : 34.342
pressure loop D2 return : 34.0124
HPH loop 1 : 219.441
HPH loop 2 : 2.40448
HPH loop 3 : 282.163
Detector High Voltage
S0
*** Map name 1:1,1:2 is missing or not properly set in the server list :
C StrawChamber 1 6 1 1
C RHRS_gc 2 5 1 1
C RHRS_s0 1 2 1 1
C RHRS_s2m 2 16 1 1
C RHRS_ps 2 24 1 1
C PRL2 2 17 1 1
C PRL1 2 17 1 1
C RHRS_SC 1 6 1 1
C RHRS_VDC 1 2 1 1
C Cerenkov 2 5 1 1
C RHRS_sh 5 15 1 1
S2 2 16 1 1
S2m
1 : -1005 -1685
2 : -1120 -1775
3 : -1025 -1720
4 : -1155 -1630
5 : -1785 -1570
6 : -1885 -1855
7 : -1855 -1830
8 : -1765 -1935
9 : -1715 -1940
10 : -1770 -1805
11 : -1635 -1785
12 : -1810 -1810
13 : -1785 -1710
14 : -1890 -1780
15 : -1515 -1655
16 : -1605 -1535
Cerenkov
1 : -1155 -1105
2 : -1025 -945
3 : -1120 -1010
4 : -1005 -1015
5 : -1020 -1180
PRL1
1 : -731 -678
2 : -667 -676
3 : -752 -687
4 : -763 -932
5 : -642 -834
6 : -727 -875
7 : -871 -707
8 : -826 -900
9 : -686 -741
10 : -659 -759
11 : -718 -620
12 : -667 -748
13 : -735 -667
14 : -745 -667
15 : -626 -718
16 : -732 -643
17 : -768 -708
PRL2
1 : -715 -641
2 : -728 -636
3 : -652 -655
4 : -711 -615
5 : -653 -577
6 : -735 -715
7 : -685 -648
8 : -704 -785
9 : -679 -725
10 : -629 -690
11 : -678 -830
12 : -653 -821
13 : -602 -648
14 : -645 -694
15 : -666 -778
16 : -698 -712
17 : -756 -690
VDC
*** Error in the HV server response:
ERROR:Hostname of mainframe not found(VDC)
Straw Chamber
1 : 1800
2 : 1800
3 : 1800
4 : 1800
5 : 1800
6 : 1800