• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name adaq

    Log entry time 14:42:24 on March 28, 2014

    Entry number 387884

    keyword=Start_Run_1286,Run_type=Cosmics,target_type=Home(no target, or empty),comment_text=T1 trigger
    Run Timestamp:       Fri Mar 28 14:42:08 EDT 2014
    Beginning-of-run EPICS data for Run Number 1286 at Fri Mar 28 14:42:16 EDT 2014
    

    Shift Worker Info

    Run_type=Cosmics target_type=Home(no target, or empty) comment_text=T1 trigger

    Prescale Values

    ;This file is automatically generated from L-HRS prescales GUI. ;To generate this file, type "prescaleL" without quotes on adaq@adaq1 ;Input the desired prescales and Save. ;T1 = L-arm s0 && S2m trigger ;T2 = L-arm s0 && GC trigger ;T3 = L-arm s2 && GC trigger ;T4 = L-arm s0 && Shower trigger ;T5 = L-arm s2m && Shower trigger ;T6 = L-arm GC && Shower trigger ;T7 = L-arm EDTM trigger ;T8 = 103.7 KHz pulser ps1=1,ps2=0,ps3=0,ps4=0,ps5=0,ps6=0,ps7=0,ps8=0

    General Run Info

    Misc Epics Info

    Left Arm Q1 momentum : 3.00003 Left Arm Q1 power supply : 2257.02 Left Arm Q1 gauss meter : -0.18779 Left Arm Q2 power supply current : 1291.76 Left Arm Q2 momentum : 2.9999 Left Arm Q2 gauss meter : 0.6819 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 1047.38 Left Arm D1 momentum : 3.00005 Left Arm D1 NMR : 1.11086 Left Arm Q3 power supply current : 1194.36 Left Arm Q3 momentum : 3.00001 Left Arm Q3 gauss meter : -0.60186 Left Arm Q3 power supply polarity : disabled Left Arm B Field Hall Probe (D-G) : -1.0711

    Target Info

    ----- Target : Empty 2 fan frequency loop 1 : 64.5 fan frequency loop 2 : 87 Encoder position : 1.74519e+07 Target type : 1.74519e+07 temperature loop 1(1) : 19.036 temperature loop 1(2) : 19.156 temperature loop 1(3) : 18.884 Heat exchange loop 1 D2 : 19.004 temperature loop 2(1) : 96.465 temperature loop 2(2) : 96.657 temperature loop 2(3) : 96.654 Heat exchange loop 2 LH2 : 96.658 pressure loop He : 0 pressure loop H2 before : 28.3223 pressure loop H2 return : 28.0827 pressure loop D2 before : 34.1634 pressure loop D2 return : 33.8949 HPH loop 1 : 208.292 HPH loop 2 : 2.42002 HPH loop 3 : 268.615

    Detector High Voltage

    S0 *** Map name 1:1,1:2 is missing or not properly set in the server list : C StrawChamber 1 6 1 1 C RHRS_gc 2 5 1 1 C RHRS_s0 1 2 1 1 C RHRS_s2m 2 16 1 1 C RHRS_ps 2 24 1 1 C PRL2 2 17 1 1 C PRL1 2 17 1 1 C RHRS_SC 1 6 1 1 C RHRS_VDC 1 2 1 1 C Cerenkov 2 5 1 1 C RHRS_sh 5 15 1 1 S2 2 16 1 1 S2m 1 : -1005 -1685 2 : -1120 -1775 3 : -1025 -1720 4 : -1155 -1630 5 : -1785 -1570 6 : -1885 -1855 7 : -1855 -1830 8 : -1765 -1935 9 : -1715 -1940 10 : -1770 -1805 11 : -1635 -1785 12 : -1810 -1810 13 : -1785 -1710 14 : -1890 -1780 15 : -1515 -1655 16 : -1605 -1535 Cerenkov 1 : -1155 -1105 2 : -1025 -945 3 : -1120 -1010 4 : -1005 -1015 5 : -1020 -1180 PRL1 1 : -731 -678 2 : -667 -676 3 : -752 -687 4 : -763 -932 5 : -642 -834 6 : -727 -875 7 : -871 -707 8 : -826 -900 9 : -686 -741 10 : -659 -759 11 : -718 -620 12 : -667 -748 13 : -735 -667 14 : -745 -667 15 : -626 -718 16 : -732 -643 17 : -768 -708 PRL2 1 : -715 -641 2 : -728 -636 3 : -652 -655 4 : -711 -615 5 : -653 -577 6 : -735 -715 7 : -685 -648 8 : -704 -785 9 : -679 -725 10 : -629 -690 11 : -678 -830 12 : -653 -821 13 : -602 -648 14 : -645 -694 15 : -666 -778 16 : -698 -712 17 : -756 -690 VDC *** Error in the HV server response: ERROR:Hostname of mainframe not found(VDC) Straw Chamber 1 : 1800 2 : 1800 3 : 1800 4 : 1800 5 : 1800 6 : 1800