Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 13:39:29 on September 17, 2014
Entry number 401157
keyword=Trigger-MLU-Settings
Settings of the HRS Trigger MLUs at Wed Sep 17 13:39:29 EDT 2014
Left HRS MLU settings:
0 0xfff7
time of Left HRS MLU last setting Sep 17 at 13:24
Right HRS MLU settings:
0 0xfff4
time of Right HRS MLU last setting Sep 17 at 13:24
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output