• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name adaq

    Log entry time 12:09:26 on October 17, 2014

    Entry number 402508

    keyword=End_of_Run_2223
    ****************************
     Run Number: 2223
     End of Run Comment:
    Run_type=Cosmics,target_type=Home(no target, or empty),comment_text=After changing DVCS copy of S2; DVCS trigger mode:  S0&S2
     
    The time between the original DVCS copy of S2 and the DVCS ADC gate varies between -107ns and -86ns.  The S0 time varies from -71ns to -65ns before the DVCS adc gate and is defining the timing.
    
    PRESCALE FACTORS:ps1=0   ps2=0   ps3=0   ps4=0   ps5=0   ps6=0   ps7=0   ps8=0   ps9=1   ps10=0   ps11=0   ps12=0   
    
    EVENTS   : 2785         
    
    TIME     : 13.350 mins  
    
    DEAD TIME:   0.00%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1: 0.0/3.5  Hz   T2:T2: 0.0/3.0  Hz   T3:T3: 0.0/4.8  Hz   T4:T4: 0.0/87.1 Hz   T5:T5: 0.0/169.4 Hz   T6:T6: 0.0/4826.1 Hz   T7:T7: 0.0/446.6 Hz   T8:T8: 0.0/103700.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:      0/2788     T2:T2:      0/2418     T3:T3:      0/3857     T4:T4:      0/69796    T5:T5:      0/135693   T6:T6:      0/3865570  T7:T7:      0/357680   T8:T8:      0/83060616  
    
    AVERAGE CURRENT
    BCM 1 : -0.0342uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : -33.5          
    BCM d1 : -21.32         
    
    
    ****************************
    End-of-run EPICS data for Run Number 2223 at Fri Oct 17 12:09:26 EDT 2014
    
    

    Target Info

    General Run Info

    Misc Epics Info