NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 12:15:32 on October 25, 2014
Entry number 402935
keyword=End_of_Run_2360
****************************
Run Number: 2360
End of Run Comment:
Run_type=Cosmics,target_type=Home(no target, or empty),comment_text=DVCS Cosmic run. HV updated. Channels 170 and 162 in ARSs. 16ns delay on channel 24.
PRESCALE FACTORS:ps1=0 ps2=0 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=0 ps9=1 ps10=0 ps11=0 ps12=0
EVENTS : 391961
TIME : 343.261 mins
DEAD TIME: 0.00%
TRIGGER RATES: PRES/REAL
T1:T1: 0.0/16.2 Hz T2:T2: 0.0/9.2 Hz T3:T3: 0.0/19.1 Hz T4:T4: 0.0/260.7 Hz T5:T5: 0.0/623.8 Hz T6:T6: 0.0/14967.1 Hz T7:T7: 0.0/1344.9 Hz T8:T8: 0.0/103700.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 0/334177 T2:T2: 0/188766 T3:T3: 0/392681 T4:T4: 0/5370218 T5:T5: 0/12847558 T6:T6: 0/308258497 T7:T7: 0/27699145 T8:T8: 0/2135772574
AVERAGE CURRENT
BCM 1 : -0.0342uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : -861.4
BCM d1 : -548.2
****************************
End-of-run EPICS data for Run Number 2360 at Sat Oct 25 12:15:11 EDT 2014
Right and Left MLU settings
Left MLU settings
0 0xffff
time of Left HRS MLU last setting Oct 25 at 12:08
Right MLU settings
1 0xffff
time of Right HRS MLU last setting Oct 25 at 12:08
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output
Misc Epics Info
Left Arm Q1 momentum : 0.000417755
Left Arm Q1 power supply : 0.267033
Left Arm Q1 gauss meter : 0.0002701
Left Arm Q2 power supply current : -0.000359404
Left Arm Q2 momentum : -8.3466e-07
Left Arm Q2 gauss meter : 0.0001978
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -2.01009
Left Arm D1 momentum : 0.00257579
Left Arm D1 NMR : 0.312023
Left Arm Q3 power supply current : -0.000586801
Left Arm Q3 momentum : -1.47393e-06
Left Arm Q3 gauss meter : 0.00056667
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.0009253
-----
Average current of the two cavities : 107
Current on Upstream bcm : 137
Current on Downstream bcm : 77
Upstream Cavity Coefficient : 1
Downstream Cavity Coefficient : 1
Upstream Pedestal : 0
Downstream Pedestal : 0
Raw Upstream Signal : 137
Raw Downstream Signal : 77
MBSY1c magnet current (amp) : 391.167
MBSY1c Bdl : 2.28838e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 0
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 9193.18
Hall A energy (halla_MeV) : 0
Delta(E)/E width (MV_AI_DXWID) : 4.33899
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04D.XPOS : 0
IPM1H04D.YPOS : 0
-----
Wien angle (Vertical) : 0
Wien Vertical BDL (Gcm) : 9.37619e-06
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 0
Wien BDL (First Solenoid) (Gcm) : -978
Wien BDL (Second Solenoid) (Gcm) : 978
Wien angle (Horizontal) : 21.6992
Wien BDL (Gcm) : 627.41
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 155
Laser power Hall A : 0
Rotating waveplate : 0
Fake Half-Wave Plate (8960=OUT) : 13056
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 500
Helicity Stable Read : 33330
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 29.5596
Target Info
-----
Target : Loop 1
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 2.11379e-38
Target type : 2.11379e-38
temperature loop 1(1) : 294.12
temperature loop 1(2) : 294.22
temperature loop 1(3) : 293.88
Heat exchange loop 1 H2 : 293.26
temperature loop 2(1) : 293.69
temperature loop 2(2) : 294.08
temperature loop 2(3) : 293.98
Heat exchange loop 2 LH2 : 292.98
temperature loop 3(1) : 295.92
temperature loop 3(2) : 295.09
temperature loop 3(3) : 296.09
Heat exchange loop 3 H2 : 294.54
pressure loop H2 before : 35.2193
pressure loop H2 return : 35.8983
pressure loop H2 before : 34.9767
pressure loop H2 return : 34.4563
HPH loop 1 : 2.12025
HPH loop 2 : 1.72084
HPH loop 3 : 1.7303
DVCS Calorimeter
Measured HV voltages
0 : -667 -724 -719 -780 -719 -805 -768 -769 -700 -747 -669 -795 -704
1 : -662 -735 -848 -782 -734 -700 -631 -723 -659 -720 -707 -703 -665
2 : -816 -741 -718 -701 -702 -722 -703 -668 -705 -710 -711 -682 -725
3 : -751 -668 -694 -648 -696 -673 -626 -671 -722 -686 -709 -730 -668
4 : -714 -742 -758 -709 -705 -764 -725 -715 -648 -677 -675 -672 -685
5 : -733 -741 -649 -783 -693 -752 -639 -650 -724 -686 -666 -766 -698
6 : -751 -752 -740 -769 -725 -687 -719 -728 -781 -668 -672 -723 -718
7 : -738 -823 -756 -689 -723 -664 -669 -665 -674 -702 -684 -627 -781
8 : -707 -765 -701 -714 -798 -632 -723 -630 -683 -665 -637 -724 -711
9 : -637 -694 -689 -809 -722 -686 -711 -702 -831 -688 -656 -748 -646
10 : -674 -758 -735 -774 -708 -717 -703 -776 -633 -758 -850 -747 -690
11 : -716 -760 -672 -768 -673 -652 -720 -729 -679 -773 -673 -707 -685
12 : -673 -716 -709 -692 -726 -629 -696 -658 -728 -693 -670 -757 -747
13 : -657 -785 -698 -739 -716 -742 -692 -759 -767 -659 -714 -701 -717
14 : -791 -756 -794 -754 -668 -678 -746 -699 -796 -690 -694 -770 -721
15 : -690 -850 -677 -729 -682 -714 -658 -743 -762 -756 -700 -634 -744
Measured HV currents
0 : -659 -717 -708 -774 -712 -795 -777 -761 -695 -738 -663 -788 -711
1 : -654 -731 -844 -778 -728 -696 -638 -716 -653 -714 -701 -698 -675
2 : -810 -735 -715 -691 -695 -718 -710 -659 -695 -706 -702 -675 -733
3 : -746 -663 -687 -643 -687 -665 -636 -666 -718 -681 -705 -721 -673
4 : -704 -738 -755 -703 -700 -759 -732 -704 -645 -667 -664 -668 -693
5 : -728 -734 -645 -775 -686 -747 -644 -644 -717 -679 -659 -757 -705
6 : -741 -745 -735 -758 -718 -683 -726 -722 -774 -657 -665 -716 -725
7 : -732 -813 -748 -683 -713 -661 -678 -658 -672 -699 -677 -623 -791
8 : -702 -759 -696 -705 -792 -627 -733 -624 -674 -657 -632 -717 -716
9 : -632 -690 -682 -804 -714 -679 -716 -696 -822 -680 -653 -742 -654
10 : -665 -750 -727 -762 -701 -708 -709 -771 -626 -751 -988 -742 -699
11 : -710 -753 -668 -758 -669 -646 -727 -722 -670 -768 -667 -698 -688
12 : -668 -712 -698 -689 -716 -623 -686 -654 -718 -687 -660 -751 -757
13 : -651 -779 -692 -731 -711 -734 -688 -752 -759 -654 -709 -693 -725
14 : -786 -753 -787 -746 -660 -670 -738 -692 -788 -682 -686 -761 -729
15 : -684 -845 -674 -723 -673 -704 -651 -734 -754 -750 -692 -627 -754
Measured anode currents: block number
0 : 0.001 0.000 0.001 0.002 -0.023 -0.021 -0.015 -0.013 -0.040 -0.027 -0.029 -0.023 -0.017
1 : 0.002 -0.001 0.001 0.002 -0.018 -0.018 -0.013 -0.016 -0.024 -0.023 -0.026 -0.028 -0.013
2 : 0.001 0.000 0.006 0.001 -0.018 -0.017 -0.016 -0.020 -0.028 -0.022 -0.027 -0.022 -0.011
3 : 0.001 -0.001 0.001 0.004 -0.021 -0.017 -0.015 -0.018 -0.024 -0.026 -0.024 -0.027 -0.012
4 : -0.278 0.000 0.001 -0.004 -0.018 -0.017 -0.015 -0.020 -0.021 -0.024 -0.026 -0.026 -0.011
5 : -0.280 0.000 0.007 0.005 -0.018 -0.018 -0.009 -0.021 -0.023 -0.026 -0.026 -0.026 -0.012
6 : -0.280 0.000 0.002 0.000 -0.021 -0.017 -1.864 -0.021 -0.023 -0.026 -0.024 -0.024 -0.012
7 : -0.278 -0.001 0.002 0.000 -0.018 -0.020 -0.015 -0.017 -0.022 -0.027 -0.026 -0.027 -0.013
8 : -0.276 -0.006 0.001 0.004 -0.018 -0.021 -0.015 -0.021 -0.029 -0.028 -0.028 -0.026 -0.015
9 : -0.277 -0.006 0.002 0.000 -0.021 -0.020 -0.016 -0.017 -0.024 -0.023 -0.024 -0.028 -0.009
10 : -0.277 -0.006 0.002 0.000 -0.021 -0.018 -0.009 -0.016 -0.026 -0.026 -0.026 -0.027 -0.016
11 : -0.277 -0.006 0.002 0.006 -0.021 -0.022 -0.011 -0.016 -0.023 -0.029 -0.026 -0.023 -0.013
12 : -0.004 -0.001 0.002 0.002 -0.023 -0.026 -0.016 -0.009 -0.017 -0.029 -0.022 -0.026 -0.012
13 : -0.004 -0.001 0.004 0.010 -0.023 -0.026 -0.016 -0.017 -0.026 -0.026 -0.027 -0.021 -0.013
14 : -0.004 0.000 0.005 0.004 -0.021 -0.016 -0.011 -0.012 -0.023 -0.031 -0.018 -0.028 -0.001
15 : -0.004 -0.001 0.004 -0.001 -0.020 -0.017 -0.018 -0.011 -0.002 -0.024 -0.024 -0.027 -0.011