NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 14:45:14 on November 2, 2014
Entry number 403278
keyword=End_of_Run_20645
****************************
Run Number: 20645
End of Run Comment:
Run_type=Cosmics,target_type=Home(no target, or empty),comment_text=GMP Test-S2 Trigger
PRESCALE FACTORS:ps1=0 ps2=1 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=0
EVENTS : 466464
TIME : 9.913 mins
DEAD TIME: 11.65%
TRIGGER RATES: PRES/REAL
T1:T1: 0.0/67.8 Hz T2:T2:887.8/887.8 Hz T3:T3: 0.0/17969.0 Hz T4:T4: 0.0/372.1 Hz T5:T5: 0.0/951.2 Hz T6:T6: 0.0/13.1 Hz T7:T7: 0.0/0.0 Hz T8:T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 0/40320 T2:T2: 528028/528028 T3:T3: 0/10687547 T4:T4: 0/221329 T5:T5: 0/565723 T6:T6: 0/7799 T7:T7: 0/0 T8:T8: 0/609052
AVERAGE CURRENT
BCM 1 : 1.8704 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 852.8
BCM d1 : 1372
****************************
End-of-run EPICS data for Run Number 20645 at Sun Nov 2 14:45:09 EST 2014
Right and Left MLU settings
Left MLU settings
1 0xffff
time of Left HRS MLU last setting Nov 2 at 11:21
Right MLU settings
1 0xffff
time of Right HRS MLU last setting Nov 2 at 11:21
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output
Target Info
General Run Info
Misc Epics Info
RHRS Detector High Voltage and Current
S0
A B
HV (V) -1325 -1100
I (uA) -306 -465
S2m
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L
HV (V) -1830 -1715 -1735 -1845 -1700 -1750 -1590 -1735 -1785 -1680 -1665 -1685 -1620 -1670 -1795 -1785
I (uA) -695 -651 -659 -699 -645 -664 -604 -659 -676 -640 -631 -639 -592 -590 -618 -629
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R
HV (V) -1775 -1665 -1705 -1710 -1850 -1675 -1890 -1790 -1720 -1575 -1750 -1800 -1940 -1825 -1830 -1850
I (uA) -674 -631 -647 -647 -702 -636 -720 -679 -651 -597 -664 -686 -686 -650 -612 -657
Cherenkov
1 2 3 4 5 6 7 8 9 10
HV (V) -1600 -1885 -2185 -1625 -1905 -1640 -1720 -1535 -1760 -1600
I (uA) -545 -635 -694 -522 -641 -544 -537 -556 -589 -531
PreShower
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L
HV (V) -1041 -896 -904 -896 -849 -913 -911 -853 -865 -859 -885 -907 -722 -891 -851 -840 -877 -899 -899 -992 -879 -1022 -858 -913
I (uA) -267 -230 -233 -230 -218 -234 -234 -219 -221 -221 -227 -233 -185 -229 -218 -215 -225 -231 -230 -255 -225 -262 -220 -235
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R
HV (V) -826 -871 -842 -863 -862 -835 -879 -844 -853 -850 -853 -844 -862 -822 -844 -900 -921 -879 -937 -904 -1032 -938 -948 -917
I (uA) -212 -224 -216 -222 -222 -214 -225 -217 -219 -219 -219 -216 -221 -211 -217 -231 -236 -225 -241 -232 -265 -241 -243 -236
Shower
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
HV (V) -841 -744 -735 -711 -734 -704 -675 -636 -682 -669 -666 -686 -747 -826 -964
I (uA) -200 -178 -175 -169 -175 -168 -160 -151 -163 -159 -158 -164 -178 -197 -230
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
HV (V) -709 -693 -657 -637 -649 -668 -647 -681 -660 -636 -652 -691 -657 -670 -830
I (uA) -169 -164 -156 -152 -154 -159 -154 -162 -157 -151 -155 -164 -156 -159 -197
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
HV (V) -669 -685 -670 -643 -639 -736 -602 -611 -697 -623 -649 -672 -687 -673 -844
I (uA) -159 -163 -160 -153 -152 -175 -143 -145 -166 -149 -154 -160 -163 -160 -201
46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
HV (V) -690 -663 -647 -661 -654 -659 -660 -609 -666 -650 -646 -675 -651 -704 -831
I (uA) -164 -158 -155 -160 -159 -160 -161 -148 -162 -159 -157 -165 -158 -171 -202
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75
HV (V) -786 -694 -714 -692 -679 -696 -673 -687 -679 -667 -728 -693 -715 -910 -815
I (uA) -186 -165 -171 -165 -162 -166 -161 -163 -162 -159 -173 -165 -170 -216 -194
VDC
1 2
HV (V) -3500 -3500
I (uA) -0 -0
Straw Chamber
1 2 3 4 5 6
HV (V) 1800 1800 1800 1800 1800 1800
I (uA) 1 1 1 1 1 1