NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 11:03:07 on December 2, 2014
Entry number 404340
keyword=Start_Run_20677,Run_type=Cosmics,target_type=Home(no target, or empty),comment_text=cosmic run
Run Timestamp: Tue Dec 2 11:02:39 EST 2014
Beginning-of-run EPICS data for Run Number 20677 at Tue Dec 2 11:03:04 EST 2014
Shift Worker Info
Run_type=Cosmics
target_type=Home(no target, or empty)
comment_text=cosmic run
Prescale Values
;This file is automatically generated from R-HRS prescales GUI.
;To generate this file, type "prescaleR" without quotes on adaq@adaql1
;Input the desired prescales and Save.
;T1 = R-arm s0 && S2m trigger
;T2 = R-arm s0 && GC trigger
;T3 = R-arm s2 && GC trigger
;T4 = R-arm s0 && Shower trigger
;T5 = R-arm s2m && Shower trigger
;T6 = R-arm GC && Shower trigger
;T7 = R-arm EDTM trigger
;T8 = 1024 Hz pulser
ps1=1,ps2=0,ps3=0,ps4=0,ps5=0,ps6=0,ps7=0,ps8=0
Right and Left MLU settings
Left MLU settings
0 0xffff
time of Left HRS MLU last setting Dec 2 at 11:01
Right MLU settings
1 0xffff
time of Right HRS MLU last setting Dec 2 at 11:01
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output
General Run Info
Misc Epics Info
-----
Right Arm Q1 momentum : 0
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : 1.02e-05
Right Arm Q2 power supply current : 1.84106e-05
Right Arm Q2 momentum : -4.96235e-07
Right Arm Q2 gauss meter : -0.0005898
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : -0.0169868
Right Arm D1 momentum : 0.00437549
Right Arm D1 NMR : 0.308798
Right Arm Q3 power supply current : -3.7363e-05
Right Arm Q3 momentum : 7.66821e-05
Right Arm Q3 gauss meter : -0.0002841
Right Arm Q3 power supply polarity : enabled
Right Arm B Field Hall Probe (D-G) : -0.00159
Target Info
-----
Target : 11
fan frequency loop 1 : 0
fan frequency loop 2 : 0
Encoder position : -4
Target type : -4
temperature loop 1(1) : 295.24
temperature loop 1(2) : 294.74
temperature loop 1(3) : 294.73
Heat exchange loop 1 D2 : 293.58
temperature loop 2(1) : 294.17
temperature loop 2(2) : 294.21
temperature loop 2(3) : 280.41
Heat exchange loop 2 LH2 : 293.36
pressure loop He : 5.29573
pressure loop H2 before : 43.2699
pressure loop H2 return : 43.6789
pressure loop D2 before : 17.1923
pressure loop D2 return : 16.9314
HPH loop 1 : 4.40961
HPH loop 2 : 2.03486
HPH loop 3 : 0.000803685
RHRS Detector High Voltage and Current
S0
A B
HV (V) I (uA)
S2m
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L
HV (V) I (uA) 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R
HV (V) I (uA)
Cherenkov
1 2 3 4 5 6 7 8 9 10
HV (V) I (uA)
PreShower
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L
HV (V) I (uA) 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R
HV (V) I (uA)
Shower
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
HV (V) I (uA) 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
HV (V) I (uA) 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
HV (V) I (uA) 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
HV (V) I (uA) 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75
HV (V) I (uA)
VDC
1 2
HV (V) I (uA)
Straw Chamber
1 2 3 4 5 6
HV (V) I (uA)