NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 15:56:32 on January 21, 2016
Entry number 408905
keyword=End_of_Run_12166
****************************
Run Number: 12166
End of Run Comment:
Run_type=Other,target_type=Home(no target, or empty),comment_text=Test DVCS DAQ
PRESCALE FACTORS:ps1=0 ps2=0 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=0 ps9=1 ps10=0 ps11=0 ps12=0
EVENTS : 510
TIME : 1.153 mins
DEAD TIME: 0.00%
TRIGGER RATES: PRES/REAL
T1:T1: 0.0/68.4 Hz T2:T2: 0.0/146.5 Hz T3:T3: 0.0/3325.6 Hz T4:T4: 0.0/32.0 Hz T5:T5: 0.0/209.6 Hz T6:T6: 0.0/12.5 Hz T7:T7: 0.0/6.3 Hz T8:T8: 0.0/103700.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 0/4732 T2:T2: 0/10140 T3:T3: 0/230109 T4:T4: 0/2214 T5:T5: 0/14500 T6:T6: 0/867 T7:T7: 0/439 T8:T8: 0/7175373
AVERAGE CURRENT
BCM 1 : 0.2388 uA BCM 3 : 0.3526 uA BCM 10: 0.0000 uA BCM new receiver: -0.0000uA
APPROXIMATE BCM CHARGES (uC)
BCM u1 : 2.135 BCM u3 : 0 BCM u10: 0 BCM u new : -9.617E-05
BCM d1 : 30.91 BCM d3 : 24.39 BCM d10: 0 BCM d new : -0.0002008
****************************
End-of-run EPICS data for Run Number 12166 at Thu Jan 21 15:55:16 EST 2016
Right and Left MLU settings
Left MLU settings
1 0xffff
time of Left HRS MLU last setting 19 at 19:01
Right MLU settings
0 0xffff
time of Right HRS MLU last setting 19 at 19:02
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output
General Run Info
Beam energy (MeV) : 10986.6
Beam Current : 0.0621755
------
Injector Measured Energy : 121.347
Average North Linac Measured Energy : 1091.18433333333333
Average South Linac Measured Energy : 1088.69666666666667
------
Left arm angle : -0.179
Left arm momentum : 0.00222309
Right arm angle : 0.197
Right arm momentum : 0.00371406
------
Fast Raster-A Ix : 0
Fast Raster-A Iy : 0
Fast Raster-B Ix : 0.2
Fast Raster-B Iy : 0
------
Hall A momentum (Tiefenbach) (HALLA:p) : 10986.6
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 11023
Hall A energy (halla_MeV) : 0
------
MBSY1c magnet current (amp) : 4
MBSY1c Bdl : 2.74706e+06
Misc Epics Info
-----
Left Arm Q1 momentum : 3.91155e-05
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0003065
Left Arm Q2 power supply current : -0.000288272
Left Arm Q2 momentum : -4.52107e-07
Left Arm Q2 gauss meter : 0.0010909
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : 0.0001826
Left Arm D1 momentum : 0.00222309
Left Arm D1 NMR : 0.19469
Left Arm Q3 power supply current : -0.000308904
Left Arm Q3 momentum : -8.22095e-07
Left Arm Q3 gauss meter : -0.0002049
Left Arm Q3 power supply polarity : enabled
Left Arm B Field Hall Probe (D-G) : -0.0008232
-----
Average current of the two cavities : 0.0617107
Current on Upstream bcm : 0.066738
Current on Downstream bcm : 0.0566833
Upstream Cavity Coefficient : 42.6
Downstream Cavity Coefficient : 43.8
Upstream Cavity Coefficient (new receiver) : IBC1H00CURA.C --- Invalid channel name
Downstream Cavity Coefficient (new receiver) : IBC1H00CURB.C --- Invalid channel name
Upstream Pedestal (new receiver) : IBC1H00CURA.B --- Invalid channel name
Downstream Pedestal (new receiver) : IBC1H00CURB.B --- Invalid channel name
Raw Upstream Signal (new receiver) : IBC1H00MAGA --- Invalid channel name
Raw Downstream Signal (new receiver) : IBC1H00MAGB --- Invalid channel name
---
MBSY1c magnet current (amp) : 4
MBSY1c Bdl : 2.74706e+06
Hall A momentum (Tiefenbach) (HALLA:p) : 10986.6
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 11023
Hall A energy (halla_MeV) : 0
Delta(E)/E width (MV_AI_DXWID) : MV_AI_DXWID --- Invalid channel name
IPM1C12.XPOS : 0
---
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04D.XPOS : IPM1H04D.XPOS --- Invalid channel name
IPM1H04D.YPOS : IPM1H04D.YPOS --- Invalid channel name
---
Moeller quadrupole currents:
MQK1H01M : 4.99986
MQO1H02M : 1.12821
MQM1H02M : -1.20879
MQO1H03M : 0
MQO1H03AM : 0.161172
MQA1H04M : 0.000915527
-----
-----
Wien angle (Vertical) : 0
Wien Vertical BDL (Gcm) : 9.37619e-06
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : -2.74963e-06
Wien BDL (First Solenoid) (Gcm) : 978
Wien BDL (Second Solenoid) (Gcm) : -978
Wien angle (Horizontal) : 0
Wien BDL (Gcm) : -7.66356e-06
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 160
Laser power Hall A : 0
Rotating waveplate : 0
Fake Half-Wave Plate (8960=OUT) : 13056
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : 8 windows
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 500
Helicity Stable Read : 33330
Helicity Delay Read : 8 windows
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 29.5596
-----
target OTR In/Out : Out
Target Info
-----
Target : Loop 1
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 2.18607e-38
Target type : 2.18607e-38
temperature loop 1(1) : 282.41
temperature loop 1(2) : 279.35
temperature loop 1(3) : 279.21
Heat exchange loop 1 H2 : 278.65
temperature loop 2(1) : 277.46
temperature loop 2(2) : 270.27
temperature loop 2(3) : 266.76
Heat exchange loop 2 LH2 : 270.8
temperature loop 3(1) : 291.3
temperature loop 3(2) : 290.57
temperature loop 3(3) : 292.44
Heat exchange loop 3 H2 : 290.39
pressure loop H2 before : 26.778
pressure loop H2 return : 33.2051
pressure loop H2 before : 30.8506
pressure loop H2 return : 28.6396
HPH loop 1 : 4.32962
HPH loop 2 : 2.22855
HPH loop 3 : 2.41937
DVCS Calorimeter
Measured HV voltages
Measured HV currents
Measured HV for DVCS Cosmic paddels
-------------------------------------------------------------------
DVCS Cosmic Padels TOP
TOP1: Error open connection(PID:0) : err-3 : errno=22
TOP2: Error open connection(PID:0) : err-3 : errno=22
DVCS Cosmic Padels BOTTOM
BOTTOM1: Error open connection(PID:0) : err-3 : errno=22
BOTTOM2: Error open connection(PID:0) : err-3 : errno=22
-------------------------------------------------------------------
Measured anode currents: block number
iochacs (129.57.242.13) needs to be reboot
Please see DVCS HOW-TO wiki for reboot IOC
LHRS Detector High Voltage and Current
S0
A B
HV (V) -1225 -1125
I (uA) -305 -523
S2m
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L
HV (V) -1595 -1525 -1840 -1765 -1730 -1635 -1715 -1655 -1705 -1810 -1795 -1745 -1715 -1800 -1590 -1450
I (uA) -605 -578 -701 -670 -658 -622 -649 -629 -646 -685 -683 -664 -650 -685 -602 -549
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R
HV (V) -1540 -1660 -1785 -1685 -1790 -1755 -1780 -1870 -1905 -1805 -1795 -1545 -1570 -1705 -1740 -1625
I (uA) -584 -631 -680 -644 -681 -668 -674 -712 -733 -685 -680 -585 -595 -646 -661 -617
Cherenkov
1 2 3 4 5 6 7 8 9 10
HV (V) -1155 -1000 -1125 -995 -1025 -1120 -935 -965 -985 -1155
I (uA) -390 -319 -392 -332 -338 -374 -309 -307 -319 -397
PRL1
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L
HV (V) -729 -669 -754 -759 -645 -729 -871 -831 -689 -663 -722 -669 -736 -750 -630 -735 -767
I (uA) -174 -159 -180 -181 -154 -173 -207 -198 -164 -157 -172 -160 -175 -178 -150 -175 -183
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R
HV (V) -678 -672 -734 -1058 -851 -906 -707 -898 -741 -761 -621 -750 -669 -667 -716 -646 -713
I (uA) -167 -166 -166 -223 -200 -210 -174 -219 -180 -186 -151 -183 -162 -162 -175 -157 -174
PRL2
18L 19L 20L 21L 22L 23L 24L 25L 26L 27L 28L 29L 30L 31L 32L 33L 34L
HV (V) -713 -733 -654 -711 -659 -739 -690 -706 -682 -628 -681 -654 -605 -647 -661 -703 -759
I (uA) -169 -175 -156 -169 -157 -175 -164 -168 -163 -150 -162 -156 -144 -154 -158 -167 -181
18R 19R 20R 21R 22R 23R 24R 25R 26R 27R 28R 29R 30R 31R 32R 33R 34R
HV (V) -649 -643 -660 -612 -576 -716 -652 -788 -729 -692 -827 -824 -654 -712 -789 -741 -714
I (uA) -155 -153 -158 -146 -138 -171 -155 -188 -174 -165 -197 -197 -161 -172 -186 -168 -166
VDC
1 2
HV (V) -3500 -3500
I (uA) -0 -0
Straw Chamber
1 2 3 4 5 6
HV (V) 1800 1800 1800 1800 1800 1800
I (uA) 2 2 3 2 2 3