NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 12:18:14 on October 10, 2016
Entry number 414059
keyword=End_of_Run_22740
****************************
Run Number: 22740
End of Run Comment:
Run_type=Other,target_type=Home(no target, or empty),comment_text=Test of RHRSbuf ps1=1, ps8=1
Alex tried unplugging the front end busy signal and we saw triggers accepted. Pluggin ti back in and triggers were suppressed.
If we want buffering to work, we'd need to make a change in the busy logic. Alex will talk with Bob about it.
PRESCALE FACTORS:ps1=1 ps2=0 ps3=0 ps4=0 ps5=0 ps6=0 ps7=0 ps8=1
EVENTS : 19897
TIME : 16.087 mins
DEAD TIME: 97.99%
TRIGGER RATES: PRES/REAL
T1:T1: 4.1/4.1 Hz T2:T2: 0.0/2.3 Hz T3:T3: 0.0/6.7 Hz T4:T4: 0.0/0.2 Hz T5:T5: 0.0/3.7 Hz T6:T6: 0.0/0.4 Hz T7:T7: 0.0/0.0 Hz T8:T8:1021.9/1021.9 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 3998/3998 T2:T2: 0/2264 T3:T3: 0/6510 T4:T4: 0/174 T5:T5: 0/3618 T6:T6: 0/404 T7:T7: 0/0 T8:T8: 986355/986355
AVERAGE CURRENT
BCM 1 : 0.8307 uA BCM 3 : 0.2730 uA BCM 10: 0.1470 uA BCM new receiver: 0.3292 uA
APPROXIMATE BCM CHARGES (uC)
BCM u1 : 828.7 BCM u3 : 0 BCM u10: 0 BCM u new : 254.2
BCM d1 : 774.9 BCM d3 : 263.5 BCM d10: 141.9 BCM d new : 381.4
****************************
End-of-run EPICS data for Run Number 22740 at Mon Oct 10 12:18:01 EDT 2016
Right and Left MLU settings
Left MLU settings
0 0xffff
time of Left HRS MLU last setting Oct 10 at 09:50
Right MLU settings
0 0xffff
time of Right HRS MLU last setting Oct 10 at 09:50
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output
General Run Info
------
Beam Energy Information:
Set Beam energy (MeV) : 2218.49
Tiefenbach 6GeV Beam energy (MeV) : 2216.26
Tiefenbach 6GeV orbit correction (dpp) : 0
Injector Measured Energy : 115.211
Average North Linac Measured Energy : 1053.20633333333333
Average South Linac Measured Energy : 1046.12333333333333
MBSY1c Magnet Current : 4
MBSY1c Bdl : 553719
Hall A ARC Current : 0.00885023
Hall A ARC Set Current : 92.4872
Lock [Y/N] : NO
Position [mm] : -0.0035
Field [T] :0
IPM1C12.XPOS : 0
------
Beam Current : 0.0604945
------
Left arm angle : -0.179
Left arm momentum : 0.00230632
Right arm angle : 48.8894
Right arm momentum : 0.00449323
------
Fast Raster-A Ix : 0
Fast Raster-A Iy : 0
Fast Raster-B Ix : 0
Fast Raster-B Iy : 0
Misc Epics Info
-----
Right Arm Q1 momentum : 0
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -3.0605e-05
Right Arm Q2 power supply current : -0.00556534
Right Arm Q2 momentum : -1.29316e-05
Right Arm Q2 gauss meter : -0.0005937
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : -0.0003584
Right Arm D1 momentum : 0.00449323
Right Arm D1 NMR : 0.310735
Right Arm Q3 power supply current : -0.000118031
Right Arm Q3 momentum : -2.96627e-07
Right Arm Q3 gauss meter : 4.72e-05
Right Arm Q3 power supply polarity : enabled
-----
Average current of the two cavities : 0.0605843
Current on Unser monitor : 17.0397
Current on Upstream bcm : 0.0658522
Current on Downstream bcm : 0.0553165
Raw Upstream Signal : -1
Raw Downstream Signal : -1
---
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
---
Moeller quadrupole currents:
MQK1H01M : -1.57023
MQO1H02M : -0.40293
MQM1H02M : -0
MQO1H03M : 0
MQO1H03AM : 0
MQA1H04M : -1.26373
-----
target OTR In/Out : Out
Target Info
Target : Loop 1
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 23.5
Encoder position : 3.35032e+07
Target type : 3.35032e+07
temperature loop 1(1) : 295.59
temperature loop 1(2) : 294.59
temperature loop 1(3) : 294.55
Heat exchange loop 1 H2 : 293.11
temperature loop 2(1) : 294.25
temperature loop 2(2) : 293.04
temperature loop 2(3) : 293.79
Heat exchange loop 2 LH2 : 291.82
temperature loop 3(1) : 35.278
temperature loop 3(2) : 59.315
temperature loop 3(3) : 32.3
Heat exchange loop 3 H2 : 59.47
pressure loop H2 before : 48.1528
pressure loop H2 return : 49.6818
pressure loop H2 before : 47.8141
pressure loop H2 return : 48.1437
HPH loop 1 : 2.82921
HPH loop 2 : 2.2829
HPH loop 3 : 0.0118783
RHRS Detector High Voltage and Current
S0
A B
Set HV (V) -1325 -1100
Read HV (V) -1326 -1102
I (uA) -305 -465
S2m
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L
Set HV (V) -1815 -1700 -1715 -1840 -1670 -1725 -1550 -1710 -1765 -1640 -1635 -1650 -1590 -1635 -1780 -1750
Read HV (V) -1815 -1701 -1715 -1841 -1671 -1727 -1550 -1711 -1766 -1640 -1635 -1652 -1590 -1635 -1780 -1752
I (uA) -689 -644 -651 -697 -634 -655 -589 -650 -670 -624 -620 -626 -565 -577 -599 -616
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R
Set HV (V) -1750 -1610 -1675 -1675 -1830 -1625 -1880 -1750 -1680 -1525 -1705 -1765 -1960 -1795 -1810 -1840
Read HV (V) -1752 -1611 -1676 -1676 -1831 -1625 -1881 -1751 -1682 -1526 -1706 -1766 -1962 -1800 -1810 -1841
I (uA) -665 -610 -636 -634 -694 -616 -716 -664 -636 -577 -647 -674 -694 -640 -602 -652
Cherenkov
1 2 3 4 5 6 7 8 9 10
Set HV (V) -1615 -1890 -2190 -1625 -1910 -1650 -1730 -1535 -1755 -1605
Read HV (V) -1615 -1890 -2190 -1625 -1910 -1651 -1731 -1535 -1755 -1606
I (uA) -551 -634 -698 -518 -635 -547 -547 -556 -585 -531
PreShower
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L
Set HV (V) -1041 -896 -904 -896 -849 -913 -911 -853 -865 -859 -885 -907 -722 -891 -851 -840 -877 -899 -899 -992 -879 -1022 -858 -913
Read HV (V) -1042 -896 -905 -897 -850 -914 -912 -853 -866 -860 -886 -908 -723 -892 -852 -841 -878 -900 -901 -993 -881 -1023 -860 -915
I (uA) -267 -230 -233 -230 -218 -234 -234 -219 -221 -221 -227 -233 -185 -229 -218 -215 -225 -231 -231 -254 -226 -262 -220 -235
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R
Set HV (V) -826 -871 -842 -863 -862 -835 -879 -844 -853 -850 -853 -844 -862 -822 -844 -900 -921 -879 -937 -904 -1032 -938 -948 -917
Read HV (V) -827 -872 -843 -865 -863 -836 -880 -846 -854 -853 -854 -845 -864 -824 -844 -901 -921 -880 -936 -905 -1033 -938 -948 -918
I (uA) -212 -224 -216 -222 -222 -214 -225 -217 -219 -219 -219 -217 -221 -211 -217 -231 -236 -225 -240 -232 -265 -241 -243 -236
Shower
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Set HV (V) -841 -744 -735 -711 -734 -704 -675 -636 -682 -669 -666 -686 -747 -826 -964
Read HV (V) -842 -745 -735 -712 -735 -705 -676 -635 -683 -669 -667 -688 -748 -827 -964
I (uA) -200 -178 -175 -169 -175 -168 -160 -151 -163 -159 -158 -164 -178 -197 -230
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set HV (V) -709 -693 -657 -637 -649 -668 -647 -681 -660 -636 -652 -691 -657 -670 -830
Read HV (V) -710 -694 -658 -638 -650 -669 -648 -682 -660 -636 -653 -693 -657 -670 -830
I (uA) -169 -165 -156 -152 -154 -159 -154 -162 -157 -151 -155 -164 -156 -159 -197
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
Set HV (V) -669 -685 -670 -643 -639 -736 -602 -611 -697 -623 -649 -672 -687 -673 -844
Read HV (V) -670 -685 -670 -643 -639 -736 -604 -611 -698 -624 -650 -673 -688 -673 -845
I (uA) -159 -163 -160 -153 -152 -175 -143 -145 -166 -149 -155 -160 -163 -160 -201
46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Set HV (V) -690 -663 -647 -661 -654 -659 -660 -609 -666 -650 -646 -675 -651 -704 -831
Read HV (V) -690 -664 -649 -661 -655 -659 -661 -609 -666 -651 -646 -675 -652 -705 -831
I (uA) -164 -158 -154 -160 -159 -160 -161 -148 -162 -159 -157 -164 -158 -171 -202
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75
Set HV (V) -786 -694 -714 -692 -679 -696 -673 -687 -679 -667 -728 -693 -715 -910 -815
Read HV (V) -786 -695 -715 -692 -680 -697 -674 -687 -680 -668 -728 -693 -716 -911 -815
I (uA) -186 -165 -170 -165 -162 -166 -161 -163 -162 -159 -173 -165 -170 -216 -194
VDC
1 2
Set HV (V) -3500 -3500
Read HV (V) -3500 -3500
I (uA) -0 -0
Straw Chamber
1 2 3 4 5 6
Set HV (V) 1800 1800 1800 1800 1800 1800
Read HV (V) 1801 1800 1800 1801 1800 1801
I (uA) 1 1 1 1 1 1