• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT
    Make New Entry, Make Followup Entry

    User name adaq

    Log entry time 20:21:26 on October 25, 2016

    Entry number 415095

    keyword=End_of_Run_22957
    ****************************
     Run Number: 22957
     End of Run Comment:
    Run_type=Production,target_type=Dummy,comment_text=40 microamp ; raster 2*3 (MCC) , production K3-9
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1   ps4=0   ps5=0   ps6=0   ps7=0   ps8=100   
    
    EVENTS   : 70905        
    
    TIME     : 14.452 mins  
    
    DEAD TIME:   6.13%      
    
    TRIGGER RATES:   PRES/REAL
    T1:T1:20.8/20.8 Hz   T2:T2:10.0/10.0 Hz   T3:T3:46.1/46.1 Hz   T4:T4: 0.0/2.4  Hz   T5:T5: 0.0/6.4  Hz   T6:T6: 0.0/0.8  Hz   T7:T7: 0.0/0.0  Hz   T8:T8:10.2/1021.9 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:T1:  18020/18020    T2:T2:   8674/8674     T3:T3:  39984/39984    T4:T4:      0/2055     T5:T5:      0/5576     T6:T6:      0/651      T7:T7:      0/0        T8:T8:   8861/886135   
    
    AVERAGE CURRENT
    BCM 1 : 35.3433uA  BCM 3 : 35.2403uA  BCM 10: 37.7688uA  BCM new receiver: 34.0867uA  
    
    APPROXIMATE BCM CHARGES (uC)
    BCM u1 : 3.061E+04      BCM u3 : 0              BCM u10: 0              BCM u new : 3.065E+04      
    BCM d1 : 3.068E+04      BCM d3 : 3.056E+04      BCM d10: 3.275E+04      BCM d new : 2.846E+04      
    
    
    ****************************
    End-of-run EPICS data for Run Number 22957 at Tue Oct 25 20:21:20 EDT 2016
    
    

    Right and Left MLU settings

    Left MLU settings 0 0xffff time of Left HRS MLU last setting Oct 13 at 10:20 Right MLU settings 0 0xffff time of Right HRS MLU last setting Oct 13 at 10:20 The meaning of the settings is documented elsewhere; briefly: first number is 0 or 1 0 = standard GMp trigger 1 = single detector trigger second number is a bit mask bit=1 means output is enabled bit=0 means output is disabled only last 8 bits are relevant for NIM output

    General Run Info

    ------

    Beam Energy Information:

    Set Beam energy (MeV) : 6418.49 Tiefenbach 6GeV Beam energy (MeV) : 6407.86 Tiefenbach 6GeV orbit correction (dpp) : 0 Injector Measured Energy : 116.414 Average North Linac Measured Energy : 1052.76533333333333 Average South Linac Measured Energy : 1048.81333333333333 MBSY1c Magnet Current : 4 MBSY1c Bdl : 1.60337e+06 Hall A ARC Current : 10.3813 Hall A ARC Set Current : 269.409 Lock [Y/N] : NO Position [mm] : 1604 Field [T] :0.707731 IPM1C12.XPOS : 0 ------ Beam Current : 0.053141 ------ Left arm angle : 30.8988 Left arm momentum : 3.22402 Right arm angle : 55.893 Right arm momentum : 1.58697 ------ Fast Raster-A Ix : 11.8 Fast Raster-A Iy : 16.758 Fast Raster-B Ix : 11.6 Fast Raster-B Iy : 20.1495

    Misc Epics Info

    ----- Right Arm Q1 momentum : 0 Right Arm Q1 power supply : 318.044 Right Arm Q1 gauss meter : 0.53583 Right Arm Q2 power supply current : 682.969 Right Arm Q2 momentum : 1.58694 Right Arm Q2 gauss meter : 0.3568 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 544.932 Right Arm D1 momentum : 1.58697 Right Arm D1 NMR : 0.588905 Right Arm Q3 power supply current : 631.561 Right Arm Q3 momentum : 1.5872 Right Arm Q3 gauss meter : 0.2822 Right Arm Q3 power supply polarity : disabled ----- Average current of the two cavities : 0.053141 Current on Unser monitor : 16.1037 Current on Upstream bcm : 0.0631466 Current on Downstream bcm : 0.0428964 Raw Upstream Signal : 48 Raw Downstream Signal : 4 --- IPM1H04A.XPOS : 0 IPM1H04A.YPOS : 0 IPM1H04B.XPOS : 0 IPM1H04B.YPOS : 0 --- Moeller quadrupole currents: MQK1H01M : -4.16932 MQO1H02M : 132 MQM1H02M : 133.531 MQO1H03M : 23.6649 MQO1H03AM : 117.011 MQA1H04M : -3.38684 ----- target OTR In/Out : Out

    Target Info

    Target : 15 cm Dummy fan frequency loop 1 : 0 fan frequency loop 2 : 60.5 fan frequency loop 3 : 0 Encoder position : 1.24229e+07 Target type : 1.24229e+07 temperature loop 1(1) : 187.4 temperature loop 1(2) : 96.141 temperature loop 1(3) : 101.17 Heat exchange loop 1 H2 : 95.311 temperature loop 2(1) : 18.989 temperature loop 2(2) : 18.961 temperature loop 2(3) : 18.577 Heat exchange loop 2 LH2 : 19.042 temperature loop 3(1) : 277.07 temperature loop 3(2) : 275.94 temperature loop 3(3) : 277.27 Heat exchange loop 3 H2 : 277.01 pressure loop H2 before : 26.5522 pressure loop H2 return : 28.2215 pressure loop H2 before : 31.1192 pressure loop H2 return : 31.3847 HPH loop 1 : 2.98282 HPH loop 2 : 379.745 HPH loop 3 : 3.36545

    RHRS Detector High Voltage and Current

    S0 A B Set HV (V) -1325 -1100 Read HV (V) -1326 -1102 I (uA) -305 -464 S2m 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L Set HV (V) -1815 -1700 -1715 -1840 -1670 -1725 -1550 -1710 -1765 -1640 -1635 -1650 -1590 -1635 -1780 -1750 Read HV (V) -1815 -1701 -1715 -1841 -1671 -1726 -1551 -1712 -1766 -1640 -1636 -1652 -1590 -1635 -1780 -1751 I (uA) -689 -644 -651 -697 -634 -655 -589 -649 -669 -624 -620 -626 -560 -576 -597 -614 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R Set HV (V) -1750 -1610 -1675 -1675 -1830 -1625 -1880 -1750 -1680 -1525 -1705 -1765 -1960 -1795 -1810 -1840 Read HV (V) -1752 -1611 -1675 -1676 -1831 -1625 -1881 -1751 -1681 -1526 -1706 -1766 -1962 -1800 -1810 -1841 I (uA) -665 -610 -636 -633 -695 -616 -716 -664 -636 -577 -647 -674 -695 -638 -603 -651 Cherenkov 1 2 3 4 5 6 7 8 9 10 Set HV (V) -1615 -1890 -2190 -1625 -1910 -1650 -1730 -1535 -1755 -1605 Read HV (V) -1615 -1890 -2190 -1625 -1910 -1650 -1730 -1535 -1755 -1606 I (uA) -562 -632 -686 -515 -641 -546 -545 -556 -584 -530 PreShower 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L Set HV (V) -1041 -896 -904 -896 -849 -913 -911 -853 -865 -859 -885 -907 -722 -891 -851 -840 -877 -899 -899 -992 -879 -1022 -858 -913 Read HV (V) -1042 -897 -905 -898 -849 -914 -912 -853 -866 -860 -886 -908 -723 -892 -852 -842 -878 -900 -900 -993 -881 -1023 -859 -915 I (uA) -267 -230 -233 -230 -218 -234 -234 -219 -221 -221 -227 -233 -185 -229 -218 -215 -225 -231 -231 -254 -226 -262 -220 -235 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R Set HV (V) -826 -871 -842 -863 -862 -835 -879 -844 -853 -850 -853 -844 -862 -822 -844 -900 -921 -879 -937 -904 -1032 -938 -948 -917 Read HV (V) -827 -873 -843 -865 -864 -836 -880 -846 -854 -853 -854 -845 -864 -824 -844 -901 -921 -880 -936 -904 -1033 -938 -948 -918 I (uA) -212 -224 -216 -222 -222 -214 -225 -217 -219 -219 -219 -217 -221 -211 -217 -231 -236 -226 -241 -232 -265 -241 -243 -236 Shower 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Set HV (V) -841 -744 -735 -711 -734 -704 -675 -636 -682 -669 -666 -686 -747 -826 -964 Read HV (V) -842 -745 -735 -711 -735 -705 -676 -636 -683 -669 -668 -688 -748 -827 -964 I (uA) -200 -178 -175 -169 -175 -168 -160 -151 -163 -159 -159 -164 -178 -197 -230 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Set HV (V) -709 -693 -657 -637 -649 -668 -647 -681 -660 -636 -652 -691 -657 -670 -830 Read HV (V) -710 -694 -658 -638 -650 -669 -648 -682 -660 -636 -653 -693 -657 -670 -830 I (uA) -169 -165 -156 -152 -154 -159 -154 -162 -157 -151 -155 -164 -156 -159 -197 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Set HV (V) -669 -685 -670 -643 -639 -736 -602 -611 -697 -623 -649 -672 -687 -673 -844 Read HV (V) -670 -686 -670 -643 -639 -736 -604 -611 -698 -624 -650 -672 -687 -673 -845 I (uA) -159 -163 -160 -153 -152 -175 -143 -146 -166 -149 -154 -160 -163 -160 -201 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Set HV (V) -690 -663 -647 -661 -654 -659 -660 -609 -666 -650 -646 -675 -651 -704 -831 Read HV (V) -690 -664 -649 -661 -655 -659 -661 -609 -666 -651 -646 -675 -652 -704 -831 I (uA) -164 -158 -155 -160 -159 -160 -161 -148 -162 -159 -157 -165 -158 -171 -202 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 Set HV (V) -786 -694 -714 -692 -679 -696 -673 -687 -679 -667 -728 -693 -715 -910 -815 Read HV (V) -786 -695 -715 -692 -680 -696 -674 -687 -680 -668 -728 -693 -716 -911 -815 I (uA) -186 -165 -170 -165 -162 -166 -161 -163 -162 -159 -173 -165 -170 -216 -194 VDC 1 2 Set HV (V) -3500 -3500 Read HV (V) -3500 -3500 I (uA) -0 -0 Straw Chamber 1 2 3 4 5 6 Set HV (V) 1800 1800 1800 1800 1800 1800 Read HV (V) 1800 1800 1800 1801 1800 1801 I (uA) 1 1 1 1 1 1