Main INDEX
Monthly INDEX
PREV
NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 04:39:05 on November 25, 2016
Entry number 416582
keyword=End_of_Run_14517
No comment file. Making halog file at Fri Nov 25 04:39:05 EST 2016
End-of-run EPICS data for Run Number 14517 at Fri Nov 25 04:38:42 EST 2016
Right and Left MLU settings
Left MLU settings
0 0xffff
time of Left HRS MLU last setting 14 at 15:39
Right MLU settings
0 0xffff
time of Right HRS MLU last setting 14 at 15:39
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output
General Run Info
------
Beam Energy Information:
Set Beam energy (MeV) : 10618.5
Tiefenbach 6GeV Beam energy (MeV) : 10592.6
Tiefenbach 6GeV orbit correction (dpp) : 0.000218293
Injector Measured Energy : 115.711
Average North Linac Measured Energy : 1053.00966666666667
Average South Linac Measured Energy : 1048.72
MBSY1c Magnet Current : 487.214
MBSY1c Bdl : 2.64818e+06
Hall A ARC Current : 487.028
Hall A ARC Set Current : 487.214
Lock [Y/N] : YES
Position [mm] : 1604
Field [T] :0.86929
IPM1C12.XPOS : -0.139701
------
Beam Current : 13.9532
------
Left arm angle : 18.6749
Left arm momentum : 3.99803
Right arm angle : 48.644
Right arm momentum : 2.16494
------
Fast Raster-A Ix : 19.6
Fast Raster-A Iy : 27.93
Fast Raster-B Ix : 19.2
Fast Raster-B Iy : 33.3165
Misc Epics Info
-----
Left Arm Q1 momentum : 1.10837
Left Arm Q1 power supply (readback) : 833.864
Left Arm Q1 power supply (set point) : 833.94
Left Arm Q1 gauss meter : -1.29479
Left Arm Q2 power supply current : 1721.29
Left Arm Q2 momentum : 3.99743
Left Arm Q2 gauss meter : 0.9001
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 1487.46
Left Arm D1 momentum : 3.99802
Left Arm D1 NMR : 1.48117
Left Arm Q3 power supply current : 1591.61
Left Arm Q3 momentum : 3.99782
Left Arm Q3 gauss meter : -0.80157
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -1.4258
-----
Average current of the two cavities : 13.9532
Current on Upstream bcm : 14.007
Current on Downstream bcm : 13.8953
Upstream Cavity Coefficient : 40.259
Downstream Cavity Coefficient : 34.043
Raw Upstream Signal (new receiver) : 6856
Raw Downstream Signal (new receiver) : 7596
---
IPM1H04A.XPOS : 0.795191
IPM1H04A.YPOS : 0.631384
IPM1H04E.XPOS : 0.803981
IPM1H04E.YPOS : 0.628797
---
Moeller quadrupole currents:
MQK1H01M : -6.79195
MQO1H02M : 222.256
MQM1H02M : 221.773
MQO1H03M : 38.1341
MQO1H03AM : 195.26
MQA1H04M : -5.51666
-----
Wien angle (Vertical) : 0
Wien Vertical BDL (Gcm) : 9.37619e-06
Wien HV Polarity : POSITIVE
Wien electrode Voltage : 0
Wien angle (Solenoids) : 0.000516931
Wien BDL (First Solenoid) (Gcm) : 978
Wien BDL (Second Solenoid) (Gcm) : -977.988
Wien angle (Horizontal) : 56.0135
Wien BDL (Gcm) : 1614.3
Wien HV Polarity (Horizontal) : POSITIVE
Wien electrode Voltage (Horizontal) : 0
Laser attenuation Hall A : 266
Laser power Hall A : 0
Rotating waveplate : 0.168
Fake Half-Wave Plate (8960=OUT) : 13119
Beam Half-wave plate (off=out) : OUT
-----
Helicity Delay Set : No Delay
Helicity Pattern Set : Quartet
Helicity Clock Set : Free Clock
Helicity Settle Read : 500
Helicity Stable Read : 33330
Helicity Delay Read : No Delay
Helicity Pattern : Quartet
Helicity Clock Read : Free Clock
Helicity Frequency : 29.5596
-----
target OTR In/Out : Out
Target Info
-----
Target : Loop 2
fan frequency loop 1 : 0
fan frequency loop 2 : 59.5
fan frequency loop 3 : 0
Encoder position : 2.57999e+07
Target type : 2.57999e+07
temperature loop 1(1) : 184.04
temperature loop 1(2) : 93.886
temperature loop 1(3) : 95.96
Heat exchange loop 1 H2 : 93.079
temperature loop 2(1) : 19.054
temperature loop 2(2) : 19.037
temperature loop 2(3) : 18.789
Heat exchange loop 2 LH2 : 19.122
temperature loop 3(1) : 279.22
temperature loop 3(2) : 278.45
temperature loop 3(3) : 280.25
Heat exchange loop 3 H2 : 279.47
pressure loop H2 before : 25.4108
pressure loop H2 return : 27.1381
pressure loop H2 before : 22.417
pressure loop H2 return : 22.9587
HPH loop 1 : 2.95942
HPH loop 2 : 119.86
HPH loop 3 : 2.66643
DVCS Calorimeter
Measured HV voltages
15 : -422.4 -447.1 -423.6 -418.7 -431.6 -401.8 -404.2 -452.9 -460.6 -444.4 -435.4 -400.4 -436.2
14 : -464.9 -453.4 -451.7 -445.7 -414.5 -392.0 -406.5 -401.9 -446.6 -399.4 -396.1 -426.3 -398.8
13 : -401.6 -466.2 -431.0 -447.7 -431.2 -441.3 -415.2 -448.4 -455.5 -408.2 -437.6 -436.4 -449.2
12 : -414.5 -424.4 -429.9 -401.4 -410.3 -371.3 -401.8 -391.0 -422.8 -398.1 -391.1 -433.3 -421.3
11 : -438.3 -443.8 -406.2 -444.7 -415.8 -397.9 -439.5 -446.1 -420.7 -449.2 -421.2 -425.9 -406.7
10 : -478.4 -460.6 -442.9 -428.2 -429.1 -400.2 -396.8 -434.6 -380.9 -437.0 -388.3 -436.2 -399.3
09 : -395.0 -421.0 -399.5 -449.5 -442.9 -396.4 -440.5 -422.7 -423.4 -395.8 -385.3 -430.8 -389.2
08 : -444.5 -448.0 -431.2 -411.7 -467.8 -390.4 -454.0 -367.5 -403.2 -413.1 -383.1 -450.0 -407.1
07 : -407.1 -414.8 -440.2 -398.7 -428.2 -383.1 -401.1 -383.4 -396.1 -396.2 -386.0 -387.3 -454.6
06 : -441.6 -445.3 -449.7 -427.4 -446.2 -408.5 -441.3 -447.9 -444.0 -407.4 -386.5 -435.5 -395.4
05 : -443.4 -429.0 -395.4 -450.8 -423.0 -428.3 -375.8 -381.8 -397.8 -387.4 -380.6 -465.4 -408.4
04 : -429.3 -457.9 -454.8 -399.1 -429.6 -442.6 -431.7 -445.8 -402.3 -417.4 -404.6 -419.4 -422.7
03 : -429.4 -417.4 -397.3 -375.4 -409.5 -394.7 -373.7 -394.6 -423.1 -397.3 -406.0 -420.4 -402.4
02 : -423.7 -421.7 -436.1 -401.4 -424.5 -411.4 -403.5 -410.2 -394.8 -423.5 -433.4 -411.0 -458.6
01 : -430.3 -437.8 -447.6 -475.6 -437.6 -406.8 -373.8 -419.5 -386.3 -416.8 -417.8 -408.7 -393.3
00 : -398.0 -434.9 -417.5 -474.4 -443.8 -452.9 -464.4 -445.1 -425.4 -467.9 -434.9 -431.5 -446.6
Measured HV currents
15 : -422.0 -444.1 -417.6 -413.6 -427.8 -394.8 -403.2 -448.7 -458.1 -440.2 -431.3 -397.1 -442.1
14 : -461.6 -451.7 -449.1 -443.7 -408.7 -389.5 -401.7 -397.3 -439.3 -396.9 -393.0 -423.7 -405.1
13 : -398.9 -459.7 -425.3 -441.5 -428.3 -438.5 -411.0 -445.6 -452.0 -406.0 -434.6 -430.1 -456.0
12 : -407.7 -421.3 -428.6 -398.6 -405.2 -365.3 -399.9 -389.1 -416.4 -392.4 -388.3 -429.9 -426.8
11 : -431.3 -440.9 -401.5 -438.4 -412.0 -395.3 -446.4 -443.1 -416.6 -443.4 -418.6 -420.3 -410.4
10 : -475.1 -457.1 -438.3 -423.3 -426.2 -395.7 -399.4 -431.1 -377.2 -432.2 -390.0 -435.6 -404.5
09 : -388.5 -414.9 -394.1 -445.4 -439.7 -391.8 -447.1 -421.1 -418.8 -393.9 -381.3 -425.8 -394.7
08 : -438.2 -446.5 -428.0 -407.4 -465.0 -387.1 -458.2 -364.2 -397.3 -408.1 -380.7 -446.9 -410.7
07 : -403.7 -410.3 -435.0 -392.4 -424.2 -382.3 -408.1 -378.0 -394.7 -394.6 -385.0 -384.5 -460.0
06 : -437.8 -438.3 -448.5 -423.8 -444.1 -404.7 -445.5 -441.8 -440.6 -401.3 -380.4 -435.1 -400.3
05 : -438.3 -427.0 -393.9 -446.4 -416.3 -424.8 -380.8 -380.1 -393.9 -386.3 -380.1 -461.0 -410.7
04 : -422.9 -453.9 -453.7 -396.3 -427.5 -440.6 -437.1 -442.1 -396.8 -412.4 -400.5 -416.2 -428.0
03 : -426.2 -417.6 -391.6 -370.1 -405.3 -390.9 -377.9 -390.2 -419.3 -395.4 -403.4 -417.9 -406.6
02 : -416.7 -419.4 -435.1 -399.1 -422.0 -408.6 -409.5 -406.9 -393.0 -421.5 -428.1 -407.1 -466.8
01 : -425.8 -437.0 -445.5 -470.5 -431.8 -402.1 -378.2 -414.7 -380.4 -415.1 -416.3 -405.6 -396.5
00 : -397.2 -428.5 -412.7 -470.0 -441.0 -448.4 -467.2 -440.9 -424.1 -461.9 -430.6 -426.7 -453.5
Measured HV for DVCS Cosmic paddels
-------------------------------------------------------------------
DVCS Cosmic Padels TOP
TOP1: 1 RC s13.10 mv -3.0
TOP2: 1 RC s13.11 mv -2.9
DVCS Cosmic Padels BOTTOM
BOTTOM1: 1 RC s13.5 mv -2.6
BOTTOM2: 1 RC s13.4 mv -2.9
-------------------------------------------------------------------
Measured anode currents: block number
iochacs (129.57.242.13) needs to be reboot
Please see DVCS HOW-TO wiki for reboot IOC
LHRS Detector High Voltage and Current
S0
A B
Set HV (V) -1225 -1125
Read HV (V) -1226 -1126
I (uA) -305 -524
S2m
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L
Set HV (V) -1540 -1490 -1775 -1730 -1685 -1620 -1700 -1655 -1705 -1780 -1775 -1735 -1695 -1800 -1560 -1450
Read HV (V) -1540 -1491 -1776 -1731 -1686 -1620 -1700 -1656 -1706 -1780 -1775 -1738 -1697 -1802 -1562 -1451
I (uA) -584 -565 -675 -657 -642 -618 -643 -630 -646 -674 -676 -659 -643 -685 -592 -550
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R
Set HV (V) -1465 -1610 -1755 -1660 -1720 -1725 -1770 -1845 -1855 -1795 -1765 -1500 -1540 -1685 -1740 -1620
Read HV (V) -1465 -1611 -1756 -1660 -1721 -1726 -1770 -1846 -1858 -1796 -1766 -1500 -1541 -1685 -1741 -1621
I (uA) -556 -612 -668 -634 -654 -655 -670 -702 -713 -681 -669 -568 -583 -638 -662 -615
Cherenkov
1 2 3 4 5 6 7 8 9 10
Set HV (V) -1155 -1000 -1125 -995 -1025 -1120 -935 -965 -985 -1155
Read HV (V) -1152 -1002 -1126 -995 -1025 -1120 -936 -965 -986 -1157
I (uA) -390 -319 -392 -332 -338 -373 -309 -307 -319 -397
PRL1
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L
Set HV (V) -729 -669 -754 -759 -645 -729 -871 -831 -689 -663 -722 -669 -736 -750 -630 -735 -767
Read HV (V) -730 -670 -754 -760 -646 -730 -873 -832 -690 -664 -723 -669 -737 -751 -630 -735 -768
I (uA) -173 -159 -180 -181 -154 -173 -207 -198 -164 -157 -172 -160 -175 -179 -150 -175 -182
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R
Set HV (V) -678 -672 -734 -1058 -851 -906 -707 -898 -741 -761 -621 -750 -669 -667 -716 -646 -713
Read HV (V) -679 -672 -733 -1060 -851 -907 -709 -898 -741 -762 -622 -750 -670 -667 -716 -647 -713
I (uA) -167 -166 -163 -223 -205 -208 -174 -219 -180 -186 -151 -183 -162 -162 -175 -157 -174
PRL2
18L 19L 20L 21L 22L 23L 24L 25L 26L 27L 28L 29L 30L 31L 32L 33L 34L
Set HV (V) -713 -733 -654 -711 -659 -739 -690 -706 -682 -628 -681 -654 -605 -647 -661 -703 -759
Read HV (V) -714 -734 -654 -712 -660 -740 -692 -707 -683 -629 -681 -655 -605 -647 -662 -704 -760
I (uA) -170 -174 -156 -169 -157 -175 -164 -168 -163 -150 -162 -156 -144 -153 -158 -167 -181
18R 19R 20R 21R 22R 23R 24R 25R 26R 27R 28R 29R 30R 31R 32R 33R 34R
Set HV (V) -649 -643 -660 -612 -576 -716 -652 -788 -729 -692 -827 -824 -654 -712 -789 -741 -714
Read HV (V) -649 -645 -660 -612 -578 -717 -653 -789 -729 -694 -828 -825 -655 -713 -790 -742 -715
I (uA) -155 -153 -158 -146 -138 -171 -155 -188 -174 -165 -197 -197 -161 -168 -191 -167 -166
VDC
1 2
Set HV (V) -3500 -3500
Read HV (V) -3500 -3500
I (uA) -0 -0
Straw Chamber
1 2 3 4 5 6
Set HV (V) 1800 1800 1800 1800 1800 1800
Read HV (V) 1801 1802 1802 1801 1802 1801
I (uA) 3 2 3 2 2 2