NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 05:31:21 on November 25, 2016
Entry number 416584
keyword=End_of_Run_23255
****************************
Run Number: 23255
End of Run Comment:
Run_type=Production,target_type=15 cm LH2 top,comment_text=Production run, 15 uA LH2 2X2 raster
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=0 ps5=0 ps6=0 ps7=0 ps8=100
EVENTS : 385632
TIME : 82.828 mins
DEAD TIME: 11.22%
TRIGGER RATES: PRES/REAL
T1:T1:16.9/16.9 Hz T2:T2:12.4/12.4 Hz T3:T3:47.9/47.9 Hz T4:T4: 0.0/0.4 Hz T5:T5: 0.0/4.7 Hz T6:T6: 0.0/0.7 Hz T7:T7: 0.0/0.0 Hz T8:T8:10.2/1022.2 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 83920/83920 T2:T2: 61619/61619 T3:T3: 238077/238077 T4:T4: 0/1953 T5:T5: 0/23254 T6:T6: 0/3360 T7:T7: 0/0 T8:T8: 50798/5079834
AVERAGE CURRENT
BCM 1 : 12.6649uA BCM 3 : 12.5602uA BCM 10: 12.5111uA BCM new receiver: 12.3714uA
APPROXIMATE BCM CHARGES (uC)
BCM u1 : 6.326E+04 BCM u3 : 0 BCM u10: 0 BCM u new : 6.272E+04
BCM d1 : 6.262E+04 BCM d3 : 6.242E+04 BCM d10: 6.218E+04 BCM d new : 6.024E+04
****************************
End-of-run EPICS data for Run Number 23255 at Fri Nov 25 05:31:15 EST 2016
Right and Left MLU settings
Left MLU settings
0 0xffff
time of Left HRS MLU last setting Nov 14 at 15:39
Right MLU settings
0 0xffff
time of Right HRS MLU last setting Nov 14 at 15:39
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output
General Run Info
------
Beam Energy Information:
Set Beam energy (MeV) : 10618.5
Tiefenbach 6GeV Beam energy (MeV) : 10592.5
Tiefenbach 6GeV orbit correction (dpp) : 0.000209357
Injector Measured Energy : 115.715
Average North Linac Measured Energy : 1052.965
Average South Linac Measured Energy : 1048.75333333333333
MBSY1c Magnet Current : 487.214
MBSY1c Bdl : 2.64818e+06
Hall A ARC Current : 487.028
Hall A ARC Set Current : 487.214
Lock [Y/N] : YES
Position [mm] : 1604
Field [T] :0.869286
IPM1C12.XPOS : -0.264032
------
Beam Current : 13.8786
------
Left arm angle : 18.6749
Left arm momentum : 3.99801
Right arm angle : 48.644
Right arm momentum : 2.16494
------
Fast Raster-A Ix : 19.6
Fast Raster-A Iy : 27.93
Fast Raster-B Ix : 19.2
Fast Raster-B Iy : 33.3165
Misc Epics Info
-----
Right Arm Q1 momentum : 0
Right Arm Q1 power supply : 433.89
Right Arm Q1 gauss meter : 0.7276
Right Arm Q2 power supply current : 931.79
Right Arm Q2 momentum : 2.1651
Right Arm Q2 gauss meter : 0.4864
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 756.005
Right Arm D1 momentum : 2.16494
Right Arm D1 NMR : 0.803384
Right Arm Q3 power supply current : 861.536
Right Arm Q3 momentum : 2.16516
Right Arm Q3 gauss meter : 0.3851
Right Arm Q3 power supply polarity : disabled
-----
Average current of the two cavities : 13.8632
Current on Unser monitor : 31.4183
Current on Upstream bcm : 13.9261
Current on Downstream bcm : 13.8004
Raw Upstream Signal : 6712
Raw Downstream Signal : 7408
---
IPM1H04A.XPOS : 0.814967
IPM1H04A.YPOS : 0.698353
IPM1H04B.XPOS : 0.838698
IPM1H04B.YPOS : 0.672537
---
Moeller quadrupole currents:
MQK1H01M : -6.79181
MQO1H02M : 217.421
MQM1H02M : 220.322
MQO1H03M : 38.1424
MQO1H03AM : 197.275
MQA1H04M : -5.51666
-----
target OTR In/Out : Out
Target Info
Target : Loop 2
fan frequency loop 1 : 0
fan frequency loop 2 : 60
fan frequency loop 3 : 0
Encoder position : 2.57999e+07
Target type : 2.57999e+07
temperature loop 1(1) : 184.02
temperature loop 1(2) : 93.876
temperature loop 1(3) : 96.334
Heat exchange loop 1 H2 : 93.007
temperature loop 2(1) : 19.028
temperature loop 2(2) : 19.034
temperature loop 2(3) : 18.794
Heat exchange loop 2 LH2 : 19.119
temperature loop 3(1) : 278.93
temperature loop 3(2) : 278.41
temperature loop 3(3) : 280.17
Heat exchange loop 3 H2 : 279.29
pressure loop H2 before : 25.4108
pressure loop H2 return : 27.2419
pressure loop H2 before : 22.4841
pressure loop H2 return : 23.0563
HPH loop 1 : 2.9192
HPH loop 2 : 117.455
HPH loop 3 : 2.58477
RHRS Detector High Voltage and Current
S0
A B
Set HV (V) -1325 -1100
Read HV (V) -1326 -1102
I (uA) -305 -464
S2m
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L
Set HV (V) -1815 -1700 -1715 -1840 -1670 -1725 -1550 -1710 -1765 -1640 -1635 -1650 -1590 -1635 -1780 -1750
Read HV (V) -1815 -1701 -1715 -1841 -1670 -1727 -1550 -1711 -1766 -1640 -1635 -1651 -1590 -1635 -1780 -1751
I (uA) -689 -644 -651 -697 -634 -654 -589 -649 -669 -625 -620 -626 -569 -576 -597 -614
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R
Set HV (V) -1750 -1610 -1675 -1675 -1830 -1625 -1880 -1750 -1680 -1525 -1705 -1765 -1960 -1795 -1810 -1840
Read HV (V) -1751 -1611 -1675 -1676 -1831 -1625 -1881 -1751 -1682 -1526 -1706 -1766 -1961 -1800 -1811 -1841
I (uA) -665 -610 -636 -633 -694 -616 -716 -664 -636 -577 -647 -674 -696 -640 -603 -652
Cherenkov
1 2 3 4 5 6 7 8 9 10
Set HV (V) -1615 -1890 -2190 -1625 -1910 -1650 -1730 -1535 -1755 -1605
Read HV (V) -1615 -1890 -2190 -1625 -1911 -1650 -1731 -1535 -1755 -1606
I (uA) -551 -632 -687 -514 -624 -546 -544 -556 -584 -531
PreShower
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L
Set HV (V) -1041 -896 -904 -896 -849 -913 -911 -853 -865 -859 -885 -907 -722 -891 -851 -840 -877 -899 -899 -992 -879 -1022 -858 -913
Read HV (V) -1042 -897 -906 -897 -849 -914 -912 -854 -866 -860 -886 -908 -723 -892 -852 -841 -878 -900 -901 -993 -881 -1023 -860 -915
I (uA) -267 -230 -233 -230 -218 -234 -234 -219 -221 -221 -227 -233 -185 -229 -218 -215 -225 -231 -231 -254 -225 -262 -220 -235
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R
Set HV (V) -826 -871 -842 -863 -862 -835 -879 -844 -853 -850 -853 -844 -862 -822 -844 -900 -921 -879 -937 -904 -1032 -938 -948 -917
Read HV (V) -827 -873 -843 -865 -864 -836 -880 -846 -854 -853 -854 -845 -864 -824 -844 -901 -920 -880 -936 -904 -1034 -938 -948 -918
I (uA) -212 -224 -216 -222 -222 -214 -225 -217 -219 -219 -219 -216 -221 -211 -217 -231 -236 -225 -240 -232 -265 -241 -243 -236
Shower
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Set HV (V) -841 -744 -735 -711 -734 -704 -675 -636 -682 -669 -666 -686 -747 -826 -964
Read HV (V) -842 -745 -735 -711 -735 -705 -676 -635 -683 -669 -667 -688 -748 -827 -964
I (uA) -200 -178 -175 -169 -175 -168 -161 -151 -163 -159 -159 -164 -178 -197 -230
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set HV (V) -709 -693 -657 -637 -649 -668 -647 -681 -660 -636 -652 -691 -657 -670 -830
Read HV (V) -710 -694 -658 -638 -650 -669 -648 -682 -660 -636 -653 -693 -657 -670 -830
I (uA) -169 -165 -156 -152 -154 -159 -154 -162 -157 -151 -155 -164 -156 -159 -197
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
Set HV (V) -669 -685 -670 -643 -639 -736 -602 -611 -697 -623 -649 -672 -687 -673 -844
Read HV (V) -670 -685 -670 -643 -639 -736 -604 -611 -698 -624 -650 -673 -688 -673 -845
I (uA) -159 -163 -160 -153 -152 -175 -143 -145 -166 -149 -155 -160 -163 -160 -201
46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Set HV (V) -690 -663 -647 -661 -654 -659 -660 -609 -666 -650 -646 -675 -651 -704 -831
Read HV (V) -690 -664 -649 -661 -655 -659 -661 -609 -666 -651 -646 -675 -652 -704 -831
I (uA) -164 -158 -155 -160 -159 -160 -161 -148 -162 -159 -157 -164 -158 -171 -202
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75
Set HV (V) -786 -694 -714 -692 -679 -696 -673 -687 -679 -667 -728 -693 -715 -910 -815
Read HV (V) -786 -694 -715 -692 -680 -696 -674 -687 -680 -668 -728 -693 -716 -911 -815
I (uA) -186 -165 -171 -165 -162 -166 -161 -163 -162 -159 -173 -165 -170 -216 -193
VDC
1 2
Set HV (V) -3500 -3500
Read HV (V) -3501 -3501
I (uA) -0 -0
Straw Chamber
1 2 3 4 5 6
Set HV (V) 1800 1800 1800 1800 1800 1800
Read HV (V) 1800 1800 1800 1801 1800 1801
I (uA) 1 1 1 1 1 1