NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 06:53:10 on November 29, 2016
Entry number 416929
keyword=End_of_Run_23342
****************************
Run Number: 23342
End of Run Comment:
Run_type=Production,target_type=15 cm LH2 top,comment_text=Production, LH2, 20uA, 2x2 Raster
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1 ps4=0 ps5=0 ps6=0 ps7=0 ps8=100
EVENTS : 310956
TIME : 59.118 mins
DEAD TIME: 11.66%
TRIGGER RATES: PRES/REAL
T1:T1:18.9/18.9 Hz T2:T2:14.1/14.1 Hz T3:T3:56.1/56.1 Hz T4:T4: 0.0/0.4 Hz T5:T5: 0.0/4.8 Hz T6:T6: 0.0/0.7 Hz T7:T7: 0.0/0.0 Hz T8:T8:10.2/1022.2 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 66913/66913 T2:T2: 49921/49921 T3:T3: 198934/198934 T4:T4: 0/1472 T5:T5: 0/16918 T6:T6: 0/2483 T7:T7: 0/0 T8:T8: 36257/3625739
AVERAGE CURRENT
BCM 1 : 15.3186uA BCM 3 : 15.1225uA BCM 10: 15.1029uA BCM new receiver: 14.9122uA
APPROXIMATE BCM CHARGES (uC)
BCM u1 : 5.46E+04 BCM u3 : 0 BCM u10: 0 BCM u new : 5.394E+04
BCM d1 : 5.407E+04 BCM d3 : 5.364E+04 BCM d10: 5.357E+04 BCM d new : 5.185E+04
****************************
End-of-run EPICS data for Run Number 23342 at Tue Nov 29 06:53:04 EST 2016
Right and Left MLU settings
Left MLU settings
0 0xffff
time of Left HRS MLU last setting Nov 14 at 15:39
Right MLU settings
0 0xffff
time of Right HRS MLU last setting Nov 14 at 15:39
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output
General Run Info
------
Beam Energy Information:
Set Beam energy (MeV) : 10618.5
Tiefenbach 6GeV Beam energy (MeV) : 10587.8
Tiefenbach 6GeV orbit correction (dpp) : -0.000237832
Injector Measured Energy : 115.715
Average North Linac Measured Energy : 1052.60166666666667
Average South Linac Measured Energy : 1048.71
MBSY1c Magnet Current : 487.214
MBSY1c Bdl : 2.64818e+06
Hall A ARC Current : 487.011
Hall A ARC Set Current : 487.214
Lock [Y/N] : YES
Position [mm] : 1604
Field [T] :0.869214
IPM1C12.XPOS : 0.241705
------
Beam Current : 19.1426
------
Left arm angle : 29.0026
Left arm momentum : 3.15403
Right arm angle : 48.644
Right arm momentum : 2.16495
------
Fast Raster-A Ix : 19.6
Fast Raster-A Iy : 27.93
Fast Raster-B Ix : 19.2
Fast Raster-B Iy : 33.3165
Misc Epics Info
-----
Right Arm Q1 momentum : 0
Right Arm Q1 power supply : 433.906
Right Arm Q1 gauss meter : 0.7276
Right Arm Q2 power supply current : 931.538
Right Arm Q2 momentum : 2.16452
Right Arm Q2 gauss meter : 0.4863
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 756
Right Arm D1 momentum : 2.16495
Right Arm D1 NMR : 0.803389
Right Arm Q3 power supply current : 861.671
Right Arm Q3 momentum : 2.1655
Right Arm Q3 gauss meter : 0.3852
Right Arm Q3 power supply polarity : disabled
-----
Average current of the two cavities : 19.1426
Current on Unser monitor : 35.4131
Current on Upstream bcm : 19.2127
Current on Downstream bcm : 19.0529
Raw Upstream Signal : 9368
Raw Downstream Signal : 10000
---
IPM1H04A.XPOS : 0.808102
IPM1H04A.YPOS : 0.56835
IPM1H04B.XPOS : 0.790441
IPM1H04B.YPOS : 0.570553
---
Moeller quadrupole currents:
MQK1H01M : -6.79196
MQO1H02M : 220
MQM1H02M : 219.436
MQO1H03M : 38.1424
MQO1H03AM : 195.824
MQA1H04M : -5.51666
-----
target OTR In/Out : Out
Target Info
Target : Loop 2
fan frequency loop 1 : 0
fan frequency loop 2 : 59
fan frequency loop 3 : 0
Encoder position : 2.57999e+07
Target type : 2.57999e+07
temperature loop 1(1) : 186.53
temperature loop 1(2) : 96.306
temperature loop 1(3) : 98.855
Heat exchange loop 1 H2 : 95.481
temperature loop 2(1) : 19.058
temperature loop 2(2) : 19.087
temperature loop 2(3) : 18.791
Heat exchange loop 2 LH2 : 19.17
temperature loop 3(1) : 278.58
temperature loop 3(2) : 277.62
temperature loop 3(3) : 279.35
Heat exchange loop 3 H2 : 278.64
pressure loop H2 before : 25.7007
pressure loop H2 return : 27.4921
pressure loop H2 before : 22.3911
pressure loop H2 return : 23.1113
HPH loop 1 : 3.02776
HPH loop 2 : 177.8
HPH loop 3 : 2.97963
RHRS Detector High Voltage and Current
S0
A B
Set HV (V) -1325 -1100
Read HV (V) -1326 -1102
I (uA) -305 -464
S2m
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L
Set HV (V) -1815 -1700 -1715 -1840 -1670 -1725 -1550 -1710 -1765 -1640 -1635 -1650 -1590 -1635 -1780 -1750
Read HV (V) -1815 -1701 -1715 -1841 -1671 -1726 -1550 -1712 -1766 -1640 -1636 -1651 -1590 -1634 -1780 -1751
I (uA) -689 -644 -651 -697 -634 -654 -589 -649 -669 -625 -620 -626 -566 -576 -596 -615
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R
Set HV (V) -1750 -1610 -1675 -1675 -1830 -1625 -1880 -1750 -1680 -1525 -1705 -1765 -1960 -1795 -1810 -1840
Read HV (V) -1752 -1611 -1675 -1676 -1831 -1625 -1881 -1751 -1681 -1525 -1706 -1766 -1962 -1800 -1810 -1841
I (uA) -665 -610 -636 -633 -694 -616 -716 -664 -636 -577 -647 -674 -697 -640 -601 -652
Cherenkov
1 2 3 4 5 6 7 8 9 10
Set HV (V) -1615 -1890 -2190 -1625 -1910 -1650 -1730 -1535 -1755 -1605
Read HV (V) -1615 -1891 -2190 -1625 -1910 -1650 -1731 -1535 -1756 -1606
I (uA) -549 -632 -686 -514 -623 -546 -545 -555 -584 -532
PreShower
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L
Set HV (V) -1041 -896 -904 -896 -849 -913 -911 -853 -865 -859 -885 -907 -722 -891 -851 -840 -877 -899 -899 -992 -879 -1022 -858 -913
Read HV (V) -1042 -897 -905 -897 -849 -914 -912 -853 -866 -860 -886 -908 -723 -892 -852 -841 -878 -900 -901 -994 -881 -1023 -860 -915
I (uA) -267 -230 -233 -230 -218 -234 -234 -219 -221 -221 -227 -233 -186 -229 -218 -215 -225 -231 -231 -254 -226 -262 -220 -235
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R
Set HV (V) -826 -871 -842 -863 -862 -835 -879 -844 -853 -850 -853 -844 -862 -822 -844 -900 -921 -879 -937 -904 -1032 -938 -948 -917
Read HV (V) -827 -873 -843 -865 -863 -836 -880 -846 -854 -853 -854 -845 -864 -824 -844 -901 -921 -880 -936 -905 -1034 -938 -948 -918
I (uA) -212 -224 -216 -222 -222 -214 -225 -217 -219 -218 -219 -217 -221 -211 -217 -231 -236 -226 -240 -232 -265 -241 -243 -236
Shower
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Set HV (V) -841 -744 -735 -711 -734 -704 -675 -636 -682 -669 -666 -686 -747 -826 -964
Read HV (V) -842 -745 -735 -711 -735 -705 -676 -636 -682 -669 -668 -688 -748 -827 -964
I (uA) -200 -178 -175 -169 -175 -168 -160 -151 -163 -159 -158 -164 -178 -197 -230
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set HV (V) -709 -693 -657 -637 -649 -668 -647 -681 -660 -636 -652 -691 -657 -670 -830
Read HV (V) -710 -694 -658 -638 -650 -669 -648 -682 -660 -636 -653 -693 -657 -670 -830
I (uA) -169 -165 -156 -152 -154 -159 -154 -162 -157 -151 -155 -164 -156 -159 -197
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
Set HV (V) -669 -685 -670 -643 -639 -736 -602 -611 -697 -623 -649 -672 -687 -673 -844
Read HV (V) -670 -685 -670 -643 -639 -736 -604 -611 -697 -624 -650 -673 -687 -673 -845
I (uA) -159 -163 -160 -153 -152 -175 -143 -145 -166 -149 -155 -160 -163 -160 -201
46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Set HV (V) -690 -663 -647 -661 -654 -659 -660 -609 -666 -650 -646 -675 -651 -704 -831
Read HV (V) -690 -664 -649 -661 -655 -659 -661 -609 -667 -651 -646 -675 -652 -704 -831
I (uA) -164 -158 -155 -160 -159 -160 -161 -148 -162 -159 -157 -165 -158 -171 -202
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75
Set HV (V) -786 -694 -714 -692 -679 -696 -673 -687 -679 -667 -728 -693 -715 -910 -815
Read HV (V) -785 -695 -715 -692 -679 -696 -674 -687 -680 -668 -728 -693 -716 -912 -815
I (uA) -186 -165 -171 -165 -162 -166 -161 -163 -162 -159 -173 -165 -170 -217 -194
VDC
1 2
Set HV (V) -3500 -3500
Read HV (V) -3501 -3500
I (uA) -0 -0
Straw Chamber
1 2 3 4 5 6
Set HV (V) 1800 1800 1800 1800 1800 1800
Read HV (V) 1800 1800 1800 1801 1800 1801
I (uA) 1 1 1 1 1 1