    keyword=Start_Run_20,Run_type=Other,target_type=Home(no target, or empty),comment_text=Test coincidences with cosmics
    Run Timestamp:       Wed Feb 15 15:29:03 EST 2017
    Beginning-of-run EPICS data for Run Number 20 at Wed Feb 15 15:29:17 EST 2017
    

    Shift Worker Info

    Run_type=Other target_type=Home(no target, or empty) comment_text=Test coincidences with cosmics

    Prescale Values

    ;This file is automatically generated from R-HRS prescales GUI. ;To generate this file, type "prescaleR" without quotes on adaq@adaql1 ;Input the desired prescales and Save. ;T1 = R-arm s0 && S2m trigger ;T2 = R-arm s0 && GC trigger ;T3 = R-arm s2 && GC trigger ;T4 = R-arm s0 && Shower trigger ;T5 = R-arm s2m && Shower trigger ;T6 = R-arm GC && Shower trigger ;T7 = R-arm EDTM trigger ;T8 = 1024 Hz pulser ps1=1,ps2=0,ps3=1,ps4=0,ps5=1,ps6=5,ps7=0,ps8=0

    Right and Left MLU settings

    Left MLU settings 0 0xffff time of Left HRS MLU last setting Jan 26 at 11:47 Right MLU settings 0 0xffff time of Right HRS MLU last setting Jan 26 at 11:47 The meaning of the settings is documented elsewhere; briefly: first number is 0 or 1 0 = standard GMp trigger 1 = single detector trigger second number is a bit mask bit=1 means output is enabled bit=0 means output is disabled only last 8 bits are relevant for NIM output

    General Run Info

    ------

    Beam Energy Information:

    Set Beam energy (MeV) : 2218.49 Tiefenbach 6GeV Beam energy (MeV) : 2216.26 Tiefenbach 6GeV orbit correction (dpp) : 0 Injector Measured Energy : 116.165 Average North Linac Measured Energy : 1053.08166666666667 Average South Linac Measured Energy : 1048.34333333333333 MBSY1c Magnet Current : 4 MBSY1c Bdl : 553719 Hall A ARC Current : 0 Hall A ARC Set Current : 92.4871 Lock [Y/N] : NO Beginning-of-run EPICS data for Run Number 20 at Wed Feb 15 15:29:18 EST 2017 Position [mm] : 0

    Shift Worker Info

    Field [T] :0.431007 Run_type=Other target_type=Home(no target, or empty) comment_text=Test coincidences with cosmics

    Prescale Values

    IPM1C12.XPOS : 0 ;This file is automatically generated from R-HRS prescales GUI. ;To generate this file, type "prescaleR" without quotes on adaq@adaql1 ;Input the desired prescales and Save. ;T1 = R-arm s0 && S2m trigger ;T2 = R-arm s0 && GC trigger ;T3 = R-arm s2 && GC trigger ;T4 = R-arm s0 && Shower trigger ;T5 = R-arm s2m && Shower trigger ;T6 = R-arm GC && Shower trigger ;T7 = R-arm EDTM trigger ;T8 = 1024 Hz pulser ps1=1,ps2=0,ps3=1,ps4=0,ps5=1,ps6=5,ps7=0,ps8=0 Beam Current : 0.0611809

    Right and Left MLU settings

    ------ Left MLU settings 0 0xffff ngle : 21.5003 time of Left HRS MLU last setting Jan 26 at 11:47 Left arm momentum : 0.00227988 Right arm angle : 49.9999 Right MLU settings Right arm momentum : 0.00431853 ------ time of Right HRS MLU last setting Jan 26 at 11:47 Fast Raster-A Ix : 0 The meaning of the settings is documented elsewhere; briefly: first number is 0 or 1 0 = standard GMp trigger Fast Raster-A Iy : 0 1 = single detector trigger second number is a bit mask bit=1 means output is enabled Fast Raster-B Ix : 0 bit=0 means output is disabled only last 8 bits are relevant for NIM output Fast Raster-B Iy : 0

    General Run Info

    Misc Epics Info

    ------ -----

    Beam Energy Information:

    Right Arm Q1 momentum : 0 Right Arm Q1 power supply : 0 Set Beam energy (MeV) : 2218.49 Right Arm Q1 gauss meter : 6.952e-06 Tiefenbach 6GeV Beam energy (MeV) : 2216.26 Right Arm Q2 power supply current : -0.00582513 Right Arm Q2 momentum : -1.35352e-05 Injector Measured Energy : 116.182 Right Arm Q2 gauss meter : 0.0002911 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 7.28e-05 Right Arm D1 momentum : 0.00431853 Right Arm D1 NMR : 0.318277 Average North Linac Measured Energy : 1053.076 Right Arm Q3 power supply current : -0.00623589 Right Arm Q3 momentum : -1.60942e-05 Right Arm Q3 gauss meter : 0.0002762 Right Arm Q3 power supply polarity : disabled Right Arm B Field Hall Probe (D-G) : -0.0015931 ----- Average South Linac Measured Energy : 1048.42333333333333 MBSY1c Magnet Current : 4 Average current of the two cavities : 0.0611809 MBSY1c Bdl : 553719 Current on Unser monitor : 13.2941 Hall A ARC Current : 0 Current on Upstream bcm : 0.067325 Hall A ARC Set Current : 92.4871 Current on Downstream bcm : 0.0550369 Lock [Y/N] : NO Position [mm] : 0 Field [T] :0.42224 IPM1C12.XPOS : 0 ------ Beam Current : 0.0611809 ------ Left arm angle : 21.5003 Left arm momentum : 0.00227988 Right arm angle : 49.9999 Right arm momentum : 0.00431853 ------ Fast Raster-A Ix : 0 Fast Raster-A Iy : 0 Fast Raster-B Ix : 0 Fast Raster-B Iy : 0

    Misc Epics Info

    ----- Right Arm Q1 momentum : 0 Right Arm Q1 power supply : 0 Right Arm Q1 gauss meter : 6.988e-06 Right Arm Q2 power supply current : -0.00548637 Right Arm Q2 momentum : -1.27481e-05 Right Arm Q2 gauss meter : 0.0002911 Right Arm Q2 power supply polarity : enabled Right Arm D1 power supply current : 7.28e-05 Right Arm D1 momentum : 0.0043417 Right Arm D1 NMR : 0.318277 Right Arm Q3 power supply current : -0.00658337 Right Arm Q3 momentum : -1.56717e-05 Right Arm Q3 gauss meter : 0.0002762 Right Arm Q3 power supply polarity : disabled Right Arm B Field Hall Probe (D-G) : -0.0015931 ----- Average current of the two cavities : 0.0611809 Current on Unser monitor : 13.2941 Current on Upstream bcm : 0.0671628 Current on Downstream bcm : 0.055693 Set Gain on Upstream bcm (new receiver): IPM1H05XVGAc.B --- Invalid channel name Set Gain on Upstream bcm (new receiver): IPM1H05XVGAc.B --- Invalid channel name Set Gain on Downstream bcm (new receiver) : IPM1H05YVGAc.B --- Invalid channel name Set Gain on Downstream bcm (new receiver) : IPM1H05YVGAc.B --- Invalid channel name Readback Gain on Upstream bcm (new receiver): IPM1H05XVGAr --- Invalid channel name Readback Gain on Upstream bcm (new receiver): IPM1H05XVGAr --- Invalid channel name Readback Gain on Downstream bcm (new receiver) : IPM1H05YVGAr --- Invalid channel name Upstream Cavity Coefficient (new receiver) : 0 Downstream Cavity Coefficient (new receiver) : 0 Upstream Pedestal (new receiver): 0 Downstream Pedestal (new receiver) : 0 Readback Gain on Downstream bcm (new receiver) : IPM1H05YVGAr --- Invalid channel name Upstream Cavity Coefficient (new receiver) : 0 Downstream Cavity Coefficient (new receiver) : 0 Upstream Pedestal (new receiver): 0 Downstream Pedestal (new receiver) : 0 Raw Upstream Signal (new receiver): IPM1H05XPM1HZ --- Invalid channel name Raw Upstream Signal (new receiver): IPM1H05XPM1HZ --- Invalid channel name Raw Downstream Signal (new receiver) : IPM1H05YPM1HZ --- Invalid channel name Raw Downstream Signal (new receiver) : IPM1H05YPM1HZ --- Invalid channel name DACSL1 A (new receiver): IPM1H05DACSL1c.A --- Invalid channel name DACSL1 A (new receiver): IPM1H05DACSL1c.A --- Invalid channel name DACSL1 B (new receiver) : IPM1H05DACSL1c.B --- Invalid channel name DACSL1 B (new receiver) : IPM1H05DACSL1c.B --- Invalid channel name DACSL2 A (new receiver): IPM1H05DACSL2c.A --- Invalid channel name DACSL2 A (new receiver): IPM1H05DACSL2c.A --- Invalid channel name DACSL2 B (new receiver) : IPM1H05DACSL2c.B --- Invalid channel name Current on Upstream bcm (new receiver): 0 Current on Downstream bcm (new receiver) : 0 ----- Left Arm Angle Floor Angle : 21.5 Left Arm Angle Vernier : 31.1 Left Arm Scattering Angle : 21.5003 ----- HacR_HPE1313A:0_Ch58 : -0.627441 HacR_HPE1313A:0_Ch55 : 21.2891 HacR_HPE1313A:0_Ch54 : -1.05029 Right Arm Angle Floor Angle : 50 Right Arm Angle Vernier : -34.2 Right Arm Scattering Angle : 49.9999 ----- IPM1H04A.XPOS : 0 IPM1H04A.YPOS : 0 IPM1H04B.XPOS : 0 IPM1H04B.YPOS : 0 Survey X offset bpmA : 0 Survey Y offset bpmA : 0 Survey X offset bpmB : 0 Survey Y offset bpmB : 0 ----- Wien angle (Vertical) : 0 Wien Vertical BDL (Gcm) : 9.37619e-06 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : 0.000516931 Wien BDL (First Solenoid) (Gcm) : 978 Wien BDL (Second Solenoid) (Gcm) : -977.988 Wien angle (Horizontal) : 0 Wien BDL (Gcm) : -7.66356e-06 Wien HV Polarity (Horizontal) : POSITIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 200.001 DACSL2 B (new receiver) : IPM1H05DACSL2c.B --- Invalid channel name Laser power Hall A : 0 Rotating waveplate : 0.168 Current on Upstream bcm (new receiver): 0 Fake Half-Wave Plate (8960=OUT) : 13119 Current on Downstream bcm (new receiver) : 0 ----- Beam Half-wave plate (off=out) : IN Left Arm Angle Floor Angle : 21.5 ----- Left Arm Angle Vernier : 31.1 Helicity Delay Set : No Delay Left Arm Scattering Angle : 21.5003 ----- Helicity Pattern Set : Quartet HacR_HPE1313A:0_Ch58 : -0.627441 HacR_HPE1313A:0_Ch55 : 21.3379 Helicity Clock Set : Free Clock HacR_HPE1313A:0_Ch54 : -1.05029 Helicity Settle Read : 500 Right Arm Angle Floor Angle : 50 Helicity Stable Read : 33330 Right Arm Angle Vernier : -34.2 Helicity Delay Read : No Delay Right Arm Scattering Angle : 49.9999 ----- Helicity Pattern : Quartet IPM1H04A.XPOS : 0 IPM1H04A.YPOS : 0 Helicity Clock Read : Free Clock IPM1H04B.XPOS : 0 : 29.5596 ----- IPM1H04B.YPOS : 0 Survey X offset bpmA : 0 ---

    Target Info

    ----- Survey Y offset bpmA : 0 Survey X offset bpmB : 0 Target : Loop 1 Survey Y offset bpmB : 0 fan frequency loop 1 : 0 ----- fan frequency loop 2 : 0 Wien angle (Vertical) : 0 fan frequency loop 3 : 0 Wien Vertical BDL (Gcm) : 9.37619e-06 Encoder position : 1 Wien HV Polarity : POSITIVE Target type : 1 Wien electrode Voltage : 0 Wien angle (Solenoids) : 0.000516931 temperature loop 1(1) : 294.43 temperature loop 1(2) : 294.43 Wien BDL (First Solenoid) (Gcm) : 978 temperature loop 1(3) : 294.24 Wien BDL (Second Solenoid) (Gcm) : -977.988 Heat exchange loop 1 H2 : 292.74 temperature loop 2(1) : 293.91 Wien angle (Horizontal) : 0 temperature loop 2(2) : 294.41 Wien BDL (Gcm) : -7.66356e-06 temperature loop 2(3) : 294.38 Wien HV Polarity (Horizontal) : POSITIVE Heat exchange loop 2 LH2 : 293.55 Wien electrode Voltage (Horizontal) : 0 temperature loop 3(1) : 302.84 temperature loop 3(2) : 303.68 Laser attenuation Hall A : 200.001 temperature loop 3(3) : 0 Laser power Hall A : 0 Heat exchange loop 3 H2 : 303.86 Rotating waveplate : 0.168 pressure loop H2 before : 13.6995 pressure loop H2 return : 16.2356 Fake Half-Wave Plate (8960=OUT) : 13119 pressure loop H2 before : 14.4732 pressure loop H2 return : 15.0194 Beam Half-wave plate (off=out) : IN HPH loop 1 : 2.58155 ----- HPH loop 2 : 2.28473 HPH loop 3 : 2.69945

    RHRS Detector High Voltage and Current

    S0 A B Set HV (V) Read HV (V) Helicity Delay Set : No Delay I (uA) S2m 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L Set HV (V) Helicity Pattern Set : Quartet Read HV (V) I (uA) Helicity Clock Set : Free Clock 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R Set HV (V) Read HV (V) le Read : 500 I (uA) Cherenkov 1 2 3 4 5 6 7 8 9 10 Set HV (V) Read HV (V) I (uA) ay Read : No Delay PreShower 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L Set HV (V) Read HV (V) ern : Quartet I (uA) 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R Set HV (V) Read HV (V) I (uA) uency : 29.5596 ----- Shower 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Set HV (V) Read HV (V) target OTR In/Out : Out I (uA)

    Target Info

    16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Set HV (V) Read HV (V) I (uA) p 1 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Set HV (V) Read HV (V) I (uA) y loop 1 : 0 fan frequency loop 2 : 0 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Set HV (V) fan frequency loop 3 : 0 Read HV (V) ion : 1 I (uA) 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 Set HV (V) Read HV (V) 1 I (uA) VDC 1 2 Set HV (V) temperature loop 1(1) : 294.5 Read HV (V) I (uA) loop 1(2) : 294.38 Straw Chamber 1 2 3 4 5 6 Set HV (V) Read HV (V) I (uA) ge loop 1 H2 : 292.72 emperature loop 2(1) : 293.91 temperature loop 2(2) : 294.41