    User name adaq

    Log entry time 13:50:34 on February 22, 2017

    Entry number 419701

    keyword=Start_Run_443,Run_type=Spot++,Run_kin=Kin3,target_type=C,leftarm_p=1799,leftarm_theta=17.5,rightarm_p=915,rightarm_theta=-47.0,beam_raster=on,comment_text=raster check ps3 =1 ps4 = 1
    Run Timestamp:       Wed Feb 22 13:49:33 EST 2017
    Beginning-of-run EPICS data for Run Number 443 at Wed Feb 22 13:49:36 EST 2017
    

    Shift Worker Info

    Run_type=Cosmics target_type=Home(no target, or empty) comment_text=test start of run script

    Prescale Values

    ;This file is automatically generated from R-HRS prescales GUI. ;To generate this file, type "prescaleR" without quotes on adaq@adaql1 ;Input the desired prescales and Save. ;T1 = (S0&&S2) && (GC||PR) [LEFT] and (S0&&S2) [RIGHT] ;T2 = (S0||S2) && (GC||PR) [LEFT] and (S0||S2) && !(PS_e) [RIGHT] ;T3 = (S0&&S2) && (GC||PR) [LEFT] ;T4 = (S0&&S2) [RIGHT] ;T5 = (S0||S2) && (GC||PR) [LEFT] ;T6 = (S0||S2) && !(PS_e) [RIGHT] ;T7 = ETDM ;T8 = 1024 Hz Pulser ps1=0,ps2=0,ps3=1,ps4=1,ps5=0,ps6=0,ps7=0,ps8=0

    Right and Left MLU settings

    Left MLU settings 0 0xffff time of Left HRS MLU last setting Jan 26 at 11:47 Right MLU settings 0 0xffff time of Right HRS MLU last setting Jan 26 at 11:47 The meaning of the settings is documented elsewhere; briefly: first number is 0 or 1 0 = standard GMp trigger 1 = single detector trigger second number is a bit mask bit=1 means output is enabled bit=0 means output is disabled only last 8 bits are relevant for NIM output

    General Run Info

    ------

    Beam Energy Information:

    Set Beam energy (MeV) : 2218.49 Tiefenbach 6GeV Beam energy (MeV) : 2217.42 Tiefenbach 6GeV orbit correction (dpp) : -0.000195766 Injector Measured Energy : 116.169 Average North Linac Measured Energy : 1052.347 Average South Linac Measured Energy : 1048.97 MBSY1c Magnet Current : 92.5542 MBSY1c Bdl : 554119 Hall A ARC Current : 92.5203 Hall A ARC Set Current : 92.5542 Lock [Y/N] : YES Position [mm] : 1604 Field [T] :0.182084 IPM1C12.XPOS : 0.28794 ------ Beam Current : 5.66458 ------ Left arm angle : 17.5003 Left arm momentum : 1.79904 Right arm angle : 46.9999 Right arm momentum : 0.914985 ------ Fast Raster-A Ix : 4 Fast Raster-A Iy : 5.7855 Fast Raster-B Ix : 4 Fast Raster-B Iy : 6.9825

    Misc Epics Info

    Left Arm Q1 momentum : 0.498741 Left Arm Q1 power supply : 375.219 Left Arm Q1 gauss meter : -0.62231 Left Arm Q2 power supply current : 774.823 Left Arm Q2 momentum : 1.7994 Left Arm Q2 gauss meter : 0.4067 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 604.621 Left Arm D1 momentum : 1.79904 Left Arm D1 NMR : 0.665753 Left Arm Q3 power supply current : 716.086 Left Arm Q3 momentum : 1.79868 Left Arm Q3 gauss meter : -0.36096 Left Arm Q3 power supply polarity : disabled Left Arm B Field Hall Probe (D-G) : -0.6418 ----- Right Arm Q1 momentum : 0 Right Arm Q1 power supply : 183.398 Right Arm Q1 gauss meter : -0.29666 Right Arm Q2 power supply current : 393.765 Right Arm Q2 momentum : 0.914952 Right Arm Q2 gauss meter : -0.2064 Right Arm Q2 power supply polarity : disabled Right Arm D1 power supply current : 314.987 Right Arm D1 momentum : 0.914985 Right Arm D1 NMR : 0.33954 Right Arm Q3 power supply current : 364.035 Right Arm Q3 momentum : 0.914871 Right Arm Q3 gauss meter : -0.16349 Right Arm Q3 power supply polarity : enabled Right Arm B Field Hall Probe (D-G) : 0.3356 ----- Average current of the two cavities : 5.66458 Current on Unser monitor : 19.0554 Current on Upstream bcm : 5.20624 Current on Downstream bcm : 6.12292 Set Gain on Upstream bcm (new receiver): IPM1H05XVGAc.B --- Invalid channel name Set Gain on Downstream bcm (new receiver) : IPM1H05YVGAc.B --- Invalid channel name Readback Gain on Upstream bcm (new receiver): IPM1H05XVGAr --- Invalid channel name Readback Gain on Downstream bcm (new receiver) : IPM1H05YVGAr --- Invalid channel name Upstream Cavity Coefficient (new receiver) : 0 Downstream Cavity Coefficient (new receiver) : 0 Upstream Pedestal (new receiver): 0 Downstream Pedestal (new receiver) : 0 Raw Upstream Signal (new receiver): IPM1H05XPM1HZ --- Invalid channel name Raw Downstream Signal (new receiver) : IPM1H05YPM1HZ --- Invalid channel name DACSL1 A (new receiver): IPM1H05DACSL1c.A --- Invalid channel name DACSL1 B (new receiver) : IPM1H05DACSL1c.B --- Invalid channel name DACSL2 A (new receiver): IPM1H05DACSL2c.A --- Invalid channel name DACSL2 B (new receiver) : IPM1H05DACSL2c.B --- Invalid channel name Current on Upstream bcm (new receiver): 0 Current on Downstream bcm (new receiver) : 0 ----- Left Arm Angle Floor Angle : 17.5 Left Arm Angle Vernier : 31.1 Left Arm Scattering Angle : 17.5003 ----- HacR_HPE1313A:0_Ch58 : -0.633301 HacR_HPE1313A:0_Ch55 : 21.1426 HacR_HPE1313A:0_Ch54 : -1.11426 Right Arm Angle Floor Angle : 47 Right Arm Angle Vernier : -34.2 Right Arm Scattering Angle : 46.9999 ----- IPM1H04A.XPOS : 0.00210001 IPM1H04A.YPOS : 0.168376 IPM1H04B.XPOS : -0.00126123 IPM1H04B.YPOS : 0.171129 Survey X offset bpmA : 0 Survey Y offset bpmA : 0 Survey X offset bpmB : 0 Survey Y offset bpmB : 0 ----- Wien angle (Vertical) : 0 Wien Vertical BDL (Gcm) : 9.37619e-06 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : 0.000516931 Wien BDL (First Solenoid) (Gcm) : 978 Wien BDL (Second Solenoid) (Gcm) : -977.988 Wien angle (Horizontal) : 0 Wien BDL (Gcm) : -7.66356e-06 Wien HV Polarity (Horizontal) : POSITIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 200.001 Laser power Hall A : 0 Rotating waveplate : 0.168 Fake Half-Wave Plate (8960=OUT) : 13119 Beam Half-wave plate (off=out) : IN ----- Helicity Delay Set : No Delay Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 500 Helicity Stable Read : 33330 Helicity Delay Read : No Delay Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 29.5596 ----- target OTR In/Out : Out ---

    Target Info

    ----- Target : Carbon hole fan frequency loop 1 : 0 fan frequency loop 2 : 28.5 fan frequency loop 3 : 0 Encoder position : 1.08754e+07 Target type : 1.08754e+07 temperature loop 1(1) : 182.06 temperature loop 1(2) : 95.882 temperature loop 1(3) : 99.914 Heat exchange loop 1 H2 : 95.177 temperature loop 2(1) : 17.256 temperature loop 2(2) : 21.132 temperature loop 2(3) : 15.465 Heat exchange loop 2 LH2 : 21.149 temperature loop 3(1) : 140.43 temperature loop 3(2) : 140.55 temperature loop 3(3) : 0 Heat exchange loop 3 H2 : 140 pressure loop H2 before : 22.6199 pressure loop H2 return : 24.9393 pressure loop H2 before : 23.27 pressure loop H2 return : 23.74 HPH loop 1 : 2.90446 HPH loop 2 : 2.33422 HPH loop 3 : 83.5802

    LHRS High Voltages

    S1L S1R S2mL S2mR CerL CerR PRL1L PRL1R PRL2L PRL2R

    RHRS Detector High Voltage and Current

    S0 A B Set HV (V) Read HV (V) I (uA) S2m 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L Set HV (V) Read HV (V) I (uA) 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R Set HV (V) Read HV (V) I (uA) Cherenkov 1 2 3 4 5 6 7 8 9 10 Set HV (V) Read HV (V) I (uA) PreShower 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L Set HV (V) Read HV (V) I (uA) 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R Set HV (V) Read HV (V) I (uA) Shower 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Set HV (V) Read HV (V) I (uA) 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Set HV (V) Read HV (V) I (uA) 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Set HV (V) Read HV (V) I (uA) 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Set HV (V) Read HV (V) I (uA) 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 Set HV (V) Read HV (V) I (uA) VDC 1 2 Set HV (V) Read HV (V) I (uA) Straw Chamber 1 2 3 4 5 6 Set HV (V) Read HV (V) I (uA)