    User name adaq

    Log entry time 02:11:01 on February 24, 2017

    Entry number 419852

    keyword=Start_Run_520,Run_type=Production,Run_kin=Kin3,target_type=Ti,leftarm_p=1799,leftarm_theta=17.5,rightarm_p=915,rightarm_theta=-47.0,beam_raster=on,comment_text=25 uA production
    Run Timestamp:       Fri Feb 24 02:09:59 EST 2017
    Beginning-of-run EPICS data for Run Number 520 at Fri Feb 24 02:10:03 EST 2017
    

    Shift Worker Info

    Run_type=Cosmics target_type=Home(no target, or empty) comment_text=test start of run script

    Prescale Values

    ;This file is automatically generated from R-HRS prescales GUI. ;To generate this file, type "prescaleR" without quotes on adaq@adaql1 ;Input the desired prescales and Save. ;T1 = (S0&&S2) && (GC||PR) [LEFT] and (S0&&S2) [RIGHT] ;T2 = (S0||S2) && (GC||PR) [LEFT] and (S0||S2) && !(PS_e) [RIGHT] ;T3 = (S0&&S2) && (GC||PR) [LEFT] ;T4 = (S0&&S2) [RIGHT] ;T5 = (S0||S2) && (GC||PR) [LEFT] ;T6 = (S0||S2) && !(PS_e) [RIGHT] ;T7 = ETDM ;T8 = 1024 Hz Pulser ps1=1,ps2=1,ps3=500,ps4=400,ps5=700,ps6=800,ps7=0,ps8=2000

    Right and Left MLU settings

    Left MLU settings 0 0xffff time of Left HRS MLU last setting Jan 26 at 11:47 Right MLU settings 0 0xffff time of Right HRS MLU last setting Jan 26 at 11:47 The meaning of the settings is documented elsewhere; briefly: first number is 0 or 1 0 = standard GMp trigger 1 = single detector trigger second number is a bit mask bit=1 means output is enabled bit=0 means output is disabled only last 8 bits are relevant for NIM output

    General Run Info

    ------

    Beam Energy Information:

    Set Beam energy (MeV) : 2218.49 Tiefenbach 6GeV Beam energy (MeV) : 2217.86 Tiefenbach 6GeV orbit correction (dpp) : 0 Injector Measured Energy : 117.892 Average North Linac Measured Energy : 1051.96266666666667 Average South Linac Measured Energy : 1049.53 MBSY1c Magnet Current : 92.5542 MBSY1c Bdl : 554119 Hall A ARC Current : 92.5203 Hall A ARC Set Current : 92.5542 Lock [Y/N] : YES Position [mm] : 1604 Field [T] :0.182082 IPM1C12.XPOS : 0 ------ Beam Current : 0.0600206 ------ Left arm angle : 17.5003 Left arm momentum : 1.799 Right arm angle : 46.9999 Right arm momentum : 0.914988 ------ Fast Raster-A Ix : 4.2 Fast Raster-A Iy : 5.7855 Fast Raster-B Ix : 4 Fast Raster-B Iy : 6.9825

    Misc Epics Info

    Left Arm Q1 momentum : 0.498741 Left Arm Q1 power supply : 375.219 Left Arm Q1 gauss meter : -0.62232 Left Arm Q2 power supply current : 774.837 Left Arm Q2 momentum : 1.79944 Left Arm Q2 gauss meter : 0.4068 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 604.611 Left Arm D1 momentum : 1.799 Left Arm D1 NMR : 0.665736 Left Arm Q3 power supply current : 716.093 Left Arm Q3 momentum : 1.79869 Left Arm Q3 gauss meter : -0.36101 Left Arm Q3 power supply polarity : disabled Left Arm B Field Hall Probe (D-G) : -0.6417 ----- Right Arm Q1 momentum : 0 Right Arm Q1 power supply : 183.429 Right Arm Q1 gauss meter : -0.29666 Right Arm Q2 power supply current : 393.77 Right Arm Q2 momentum : 0.914962 Right Arm Q2 gauss meter : -0.2064 Right Arm Q2 power supply polarity : disabled Right Arm D1 power supply current : 314.986 Right Arm D1 momentum : 0.914986 Right Arm D1 NMR : 0.33954 Right Arm Q3 power supply current : 364.037 Right Arm Q3 momentum : 0.914876 Right Arm Q3 gauss meter : -0.1635 Right Arm Q3 power supply polarity : enabled Right Arm B Field Hall Probe (D-G) : 0.3356 ----- Average current of the two cavities : 0.0600206 Current on Unser monitor : 13.8787 Current on Upstream bcm : 0.0654083 Current on Downstream bcm : 0.0546329 Set Gain on Upstream bcm (new receiver): IPM1H05XVGAc.B --- Invalid channel name Set Gain on Downstream bcm (new receiver) : IPM1H05YVGAc.B --- Invalid channel name Readback Gain on Upstream bcm (new receiver): IPM1H05XVGAr --- Invalid channel name Readback Gain on Downstream bcm (new receiver) : IPM1H05YVGAr --- Invalid channel name Upstream Cavity Coefficient (new receiver) : 0 Downstream Cavity Coefficient (new receiver) : 0 Upstream Pedestal (new receiver): 0 Downstream Pedestal (new receiver) : 0 Raw Upstream Signal (new receiver): IPM1H05XPM1HZ --- Invalid channel name Raw Downstream Signal (new receiver) : IPM1H05YPM1HZ --- Invalid channel name DACSL1 A (new receiver): IPM1H05DACSL1c.A --- Invalid channel name DACSL1 B (new receiver) : IPM1H05DACSL1c.B --- Invalid channel name DACSL2 A (new receiver): IPM1H05DACSL2c.A --- Invalid channel name DACSL2 B (new receiver) : IPM1H05DACSL2c.B --- Invalid channel name Current on Upstream bcm (new receiver): 0 Current on Downstream bcm (new receiver) : 0 ----- Left Arm Angle Floor Angle : 17.5 Left Arm Angle Vernier : 31.1 Left Arm Scattering Angle : 17.5003 ----- HacR_HPE1313A:0_Ch58 : -0.633301 HacR_HPE1313A:0_Ch55 : 20.9473 HacR_HPE1313A:0_Ch54 : -1.11719 Right Arm Angle Floor Angle : 47 Right Arm Angle Vernier : -34.2 Right Arm Scattering Angle : 46.9999 ----- IPM1H04A.XPOS : 0 IPM1H04A.YPOS : 0 IPM1H04B.XPOS : 0 IPM1H04B.YPOS : 0 Survey X offset bpmA : 0 Survey Y offset bpmA : 0 Survey X offset bpmB : 0 Survey Y offset bpmB : 0 ----- Wien angle (Vertical) : 0 Wien Vertical BDL (Gcm) : 9.37619e-06 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : 0.000516931 Wien BDL (First Solenoid) (Gcm) : 978 Wien BDL (Second Solenoid) (Gcm) : -977.988 Wien angle (Horizontal) : 0 Wien BDL (Gcm) : -7.66356e-06 Wien HV Polarity (Horizontal) : POSITIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 200.001 Laser power Hall A : 0 Rotating waveplate : 0.168 Fake Half-Wave Plate (8960=OUT) : 13119 Beam Half-wave plate (off=out) : IN ----- Helicity Delay Set : No Delay Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 500 Helicity Stable Read : 33330 Helicity Delay Read : No Delay Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 29.5596 ----- target OTR In/Out : Out ---

    Target Info

    ----- Target : Titanium fan frequency loop 1 : 0 fan frequency loop 2 : 29 fan frequency loop 3 : 0 Encoder position : 1.23059e+07 Target type : 1.23059e+07 temperature loop 1(1) : 184.57 temperature loop 1(2) : 97.317 temperature loop 1(3) : 105.93 Heat exchange loop 1 H2 : 96.537 temperature loop 2(1) : 17.395 temperature loop 2(2) : 21.213 temperature loop 2(3) : 15.531 Heat exchange loop 2 LH2 : 21.253 temperature loop 3(1) : 141.74 temperature loop 3(2) : 141.78 temperature loop 3(3) : 0 Heat exchange loop 3 H2 : 140 pressure loop H2 before : 22.7985 pressure loop H2 return : 25.1407 pressure loop H2 before : 23.4226 pressure loop H2 return : 23.9627 HPH loop 1 : 3.12084 HPH loop 2 : 2.27198 HPH loop 3 : 60.0714

    LHRS High Voltages

    S1L S1R S2mL S2mR CerL CerR PRL1L PRL1R PRL2L PRL2R

    RHRS Detector High Voltage and Current

    S0 A B Set HV (V) Read HV (V) I (uA) S2m 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L Set HV (V) Read HV (V) I (uA) 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R Set HV (V) Read HV (V) I (uA) Cherenkov 1 2 3 4 5 6 7 8 9 10 Set HV (V) Read HV (V) I (uA) PreShower 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L Set HV (V) Read HV (V) I (uA) 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R Set HV (V) Read HV (V) I (uA) Shower 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Set HV (V) Read HV (V) I (uA) 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Set HV (V) Read HV (V) I (uA) 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Set HV (V) Read HV (V) I (uA) 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Set HV (V) Read HV (V) I (uA) 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 Set HV (V) Read HV (V) I (uA) VDC 1 2 Set HV (V) Read HV (V) I (uA) Straw Chamber 1 2 3 4 5 6 Set HV (V) Read HV (V) I (uA)