    User name adaq

    Log entry time 04:05:49 on March 1, 2017

    Entry number 420144

    keyword=Start_Run_675,Run_type=Production,Run_kin=Kin5,target_type= Ti ,leftarm_p=1716,leftarm_theta=15.5,rightarm_p=1030,rightarm_theta=-39,beam_raster=on,comment_text=Prescale check!, 5-10 uA,n PS= (1,1,450,225,500,250,0,2000)
    Run Timestamp:       Wed Mar  1 04:05:14 EST 2017
    Beginning-of-run EPICS data for Run Number 675 at Wed Mar 1 04:05:38 EST 2017
    

    Shift Worker Info

    Run_type=Cosmics target_type=Home(no target, or empty) comment_text=test start of run script

    Prescale Values

    ;This file is automatically generated from R-HRS prescales GUI. ;To generate this file, type "prescaleR" without quotes on adaq@adaql1 ;Input the desired prescales and Save. ;T1 = R-arm s0 && S2m trigger ;T2 = R-arm s0 && GC trigger ;T3 = R-arm s2 && GC trigger ;T4 = R-arm s0 && Shower trigger ;T5 = R-arm s2m && Shower trigger ;T6 = R-arm GC && Shower trigger ;T7 = R-arm EDTM trigger ;T8 = 1024 Hz pulser ps1=1,ps2=1,ps3=450,ps4=225,ps5=500,ps6=250,ps7=0,ps8=2000

    Right and Left MLU settings

    Left MLU settings 0 0xffff time of Left HRS MLU last setting Jan 26 at 11:47 Right MLU settings 0 0xffff time of Right HRS MLU last setting Jan 26 at 11:47 The meaning of the settings is documented elsewhere; briefly: first number is 0 or 1 0 = standard GMp trigger 1 = single detector trigger second number is a bit mask bit=1 means output is enabled bit=0 means output is disabled only last 8 bits are relevant for NIM output

    General Run Info

    ------

    Beam Energy Information:

    Set Beam energy (MeV) : 2218.49 Tiefenbach 6GeV Beam energy (MeV) : 2218.57 Tiefenbach 6GeV orbit correction (dpp) : -4.03988e-05 Injector Measured Energy : 115.863 Average North Linac Measured Energy : 1052.64233333333333 Average South Linac Measured Energy : 1049.52 MBSY1c Magnet Current : 92.5878 MBSY1c Bdl : 554319 Hall A ARC Current : 92.5469 Hall A ARC Set Current : 92.5878 Lock [Y/N] : YES Position [mm] : 1604 Field [T] :0.182148 IPM1C12.XPOS : -0.282459 ------ Beam Current : 4.56618 ------ Left arm angle : 15.5285 Left arm momentum : 1.71603 Right arm angle : 38.9999 Right arm momentum : 1.03003 ------ Fast Raster-A Ix : 4 Fast Raster-A Iy : 5.7855 Fast Raster-B Ix : 4 Fast Raster-B Iy : 6.9825

    Misc Epics Info

    Left Arm Q1 momentum : 0.498741 Left Arm Q1 power supply : 375.203 Left Arm Q1 gauss meter : -0.62229 Left Arm Q2 power supply current : 738.771 Left Arm Q2 momentum : 1.71568 Left Arm Q2 gauss meter : 0.3879 Left Arm Q2 power supply polarity : disabled Left Arm D1 power supply current : 575.037 Left Arm D1 momentum : 1.71603 Left Arm D1 NMR : 0.635052 Left Arm Q3 power supply current : 683.205 Left Arm Q3 momentum : 1.71609 Left Arm Q3 gauss meter : -0.34446 Left Arm Q3 power supply polarity : disabled Left Arm B Field Hall Probe (D-G) : -0.6121 ----- Right Arm Q1 momentum : 0 Right Arm Q1 power supply : 183.398 Right Arm Q1 gauss meter : -0.29662 Right Arm Q2 power supply current : 443.32 Right Arm Q2 momentum : 1.0301 Right Arm Q2 gauss meter : -0.2322 Right Arm Q2 power supply polarity : disabled Right Arm D1 power supply current : 354.716 Right Arm D1 momentum : 1.03003 Right Arm D1 NMR : 0.38223 Right Arm Q3 power supply current : 409.846 Right Arm Q3 momentum : 1.03 Right Arm Q3 gauss meter : -0.18393 Right Arm Q3 power supply polarity : enabled Right Arm B Field Hall Probe (D-G) : 0.3778 ----- Average current of the two cavities : 4.56294 Current on Unser monitor : 18.0859 Current on Upstream bcm : 4.53195 Current on Downstream bcm : 4.59392 Set Gain on Upstream bcm (new receiver): 5 Set Gain on Downstream bcm (new receiver) : 5 Readback Gain on Upstream bcm (new receiver): 1280 Readback Gain on Downstream bcm (new receiver) : 1280 Upstream Cavity Coefficient (new receiver) : 0 Downstream Cavity Coefficient (new receiver) : 0 Upstream Pedestal (new receiver): 0 Downstream Pedestal (new receiver) : 0 Raw Upstream Signal (new receiver): 2568 Raw Downstream Signal (new receiver) : 2604 DACSL1 A (new receiver): 2 DACSL1 B (new receiver) : 2 DACSL2 A (new receiver): 2 DACSL2 B (new receiver) : 2 Current on Upstream bcm (new receiver): 0 Current on Downstream bcm (new receiver) : 0 ----- Left Arm Angle Floor Angle : 15.5 Left Arm Angle Vernier : 36 Left Arm Scattering Angle : 15.5285 ----- HacR_HPE1313A:0_Ch58 : -0.644531 HacR_HPE1313A:0_Ch55 : 20.8984 HacR_HPE1313A:0_Ch54 : -1.18262 Right Arm Angle Floor Angle : 39 Right Arm Angle Vernier : -34.2 Right Arm Scattering Angle : 38.9999 ----- IPM1H04A.XPOS : 1.73147 IPM1H04A.YPOS : 0.476236 IPM1H04B.XPOS : 1.73676 IPM1H04B.YPOS : 0.463571 Survey X offset bpmA : 0 Survey Y offset bpmA : 0 Survey X offset bpmB : 0 Survey Y offset bpmB : 0 ----- Wien angle (Vertical) : 0 Wien Vertical BDL (Gcm) : 0 Wien HV Polarity : POSITIVE Wien electrode Voltage : 0 Wien angle (Solenoids) : 0.0005406 Wien BDL (First Solenoid) (Gcm) : 978 Wien BDL (Second Solenoid) (Gcm) : -977.988 Wien angle (Horizontal) : 0 Wien BDL (Gcm) : -0 Wien HV Polarity (Horizontal) : POSITIVE Wien electrode Voltage (Horizontal) : 0 Laser attenuation Hall A : 200.001 Laser power Hall A : 0 Rotating waveplate : 0.168 Fake Half-Wave Plate (8960=OUT) : 13119 Beam Half-wave plate (off=out) : IN ----- Helicity Delay Set : No Delay Helicity Pattern Set : Quartet Helicity Clock Set : Free Clock Helicity Settle Read : 500 Helicity Stable Read : 33330 Helicity Delay Read : No Delay Helicity Pattern : Quartet Helicity Clock Read : Free Clock Helicity Frequency : 29.5596 ----- target OTR In/Out : Out ---

    Target Info

    ----- Target : Titanium fan frequency loop 1 : 0 fan frequency loop 2 : 29 fan frequency loop 3 : 0 Encoder position : 1.23059e+07 Target type : 1.23059e+07 temperature loop 1(1) : 184.44 temperature loop 1(2) : 98.526 temperature loop 1(3) : 109.1 Heat exchange loop 1 H2 : 97.783 temperature loop 2(1) : 16.977 temperature loop 2(2) : 21.134 temperature loop 2(3) : 15.006 Heat exchange loop 2 LH2 : 21.222 temperature loop 3(1) : 140.73 temperature loop 3(2) : 140.9 temperature loop 3(3) : 0 Heat exchange loop 3 H2 : 139.98 pressure loop H2 before : 22.2491 pressure loop H2 return : 24.7425 pressure loop H2 before : 23.0655 pressure loop H2 return : 23.4943 HPH loop 1 : 2.86044 HPH loop 2 : 2.53752 HPH loop 3 : 74.0407

    LHRS Detector High Voltage and Current

    S0 A B Set HV (V) -1225 -1125 Read HV (V) -1227 -1126 I (uA) -305 -523 S2m 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L Set HV (V) -1540 -1490 -1775 -1730 -1685 -1625 -1700 -1655 -1705 -1780 -1775 -1735 -1695 -1800 -1560 -1450 Read HV (V) -1540 -1491 -1776 -1731 -1686 -1626 -1700 -1656 -1706 -1780 -1775 -1738 -1697 -1802 -1562 -1451 I (uA) -584 -565 -675 -657 -642 -619 -644 -630 -646 -674 -675 -660 -642 -685 -591 -549 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R Set HV (V) -1465 -1610 -1755 -1660 -1720 -1725 -1770 -1845 -1855 -1795 -1765 -1500 -1540 -1685 -1740 -1620 Read HV (V) -1465 -1611 -1757 -1660 -1721 -1726 -1770 -1846 -1857 -1796 -1766 -1500 -1541 -1686 -1740 -1621 I (uA) -555 -611 -668 -634 -653 -656 -670 -702 -713 -680 -669 -568 -583 -638 -662 -615 Cherenkov 1 2 3 4 5 6 7 8 9 10 Set HV (V) -1155 -1000 -1125 -995 -1025 -1120 -935 -965 -985 -1155 Read HV (V) -1153 -1002 -1126 -995 -1025 -1120 -936 -965 -986 -1156 I (uA) -389 -319 -393 -332 -338 -374 -308 -307 -319 -397 PRL1 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L Set HV (V) -729 -669 -754 -759 -645 -729 -871 -831 -689 -663 -722 -669 -736 -750 -630 -735 -767 Read HV (V) -730 -670 -754 -760 -646 -730 -873 -832 -690 -664 -723 -669 -737 -751 -630 -735 -768 I (uA) -173 -159 -180 -181 -154 -174 -207 -198 -163 -157 -172 -160 -175 -179 -150 -175 -182 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R Set HV (V) -678 -672 -734 -1058 -851 -906 -707 -898 -741 -761 -621 -750 -669 -667 -716 -646 -713 Read HV (V) -679 -672 -733 -1059 -851 -907 -709 -898 -742 -762 -622 -750 -670 -667 -716 -648 -713 I (uA) -167 -166 -164 -225 -207 -210 -174 -219 -180 -186 -151 -183 -162 -162 -175 -157 -174 PRL2 18L 19L 20L 21L 22L 23L 24L 25L 26L 27L 28L 29L 30L 31L 32L 33L 34L Set HV (V) -713 -733 -654 -711 -659 -739 -690 -706 -682 -628 -681 -654 -605 -647 -661 -703 -759 Read HV (V) -714 -734 -654 -712 -659 -740 -691 -707 -683 -630 -681 -655 -605 -647 -661 -704 -760 I (uA) -169 -175 -156 -169 -157 -175 -164 -168 -162 -150 -162 -157 -144 -154 -158 -167 -181 18R 19R 20R 21R 22R 23R 24R 25R 26R 27R 28R 29R 30R 31R 32R 33R 34R Set HV (V) -649 -643 -660 -612 -576 -716 -652 -788 -729 -692 -827 -824 -654 -712 -789 -741 -714 Read HV (V) -650 -645 -660 -612 -578 -717 -653 -789 -729 -694 -828 -825 -655 -713 -790 -742 -715 I (uA) -155 -153 -158 -146 -138 -171 -155 -188 -173 -165 -197 -197 -161 -173 -189 -170 -168 VDC 1 2 Set HV (V) -3500 -3500 Read HV (V) -3500 -3500 I (uA) -0 -0 Straw Chamber 1 2 3 4 5 6 Set HV (V) 1800 1800 1800 1800 1800 1800 Read HV (V) 1800 1802 1802 1801 1801 1801 I (uA) 2 2 3 2 2 3

    RHRS Detector High Voltage and Current

    S0 A B Set HV (V) -1325 -1250 Read HV (V) -1326 -1252 I (uA) -305 -528 S2m 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L Set HV (V) -1815 -1700 -1715 -1840 -1670 -1725 -1550 -1710 -1765 -1640 -1635 -1650 -1590 -1635 -1780 -1750 Read HV (V) -1815 -1701 -1715 -1841 -1671 -1726 -1550 -1712 -1766 -1640 -1635 -1652 -1590 -1635 -1780 -1751 I (uA) -689 -644 -651 -697 -634 -654 -588 -649 -670 -625 -620 -626 -564 -576 -595 -612 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R Set HV (V) -1750 -1610 -1675 -1675 -1830 -1625 -1880 -1750 -1680 -1525 -1705 -1765 -1960 -1795 -1810 -1840 Read HV (V) -1751 -1611 -1675 -1676 -1831 -1625 -1881 -1751 -1682 -1526 -1706 -1766 -1962 -1800 -1810 -1841 I (uA) -665 -610 -636 -633 -695 -616 -716 -664 -636 -577 -647 -675 -693 -641 -598 -650 Cherenkov 1 2 3 4 5 6 7 8 9 10 Set HV (V) -1615 -1890 -2190 -1625 -1910 -1650 -1730 -1535 -1755 -1605 Read HV (V) -1616 -1890 -2190 -1625 -1911 -1650 -1730 -1535 -1756 -1606 I (uA) -549 -633 -684 -514 -620 -546 -542 -555 -585 -532 PreShower 1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L Set HV (V) -1041 -896 -904 -896 -849 -913 -911 -853 -865 -859 -885 -907 -722 -891 -851 -840 -877 -899 -899 -992 -879 -1022 -858 -913 Read HV (V) -1042 -897 -905 -898 -849 -914 -912 -854 -866 -860 -886 -908 -723 -892 -852 -842 -878 -900 -901 -993 -881 -1023 -859 -915 I (uA) -267 -230 -233 -230 -218 -234 -234 -219 -221 -221 -227 -233 -185 -229 -218 -215 -225 -231 -231 -254 -226 -262 -220 -235 1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R Set HV (V) -826 -871 -842 -863 -862 -835 -879 -844 -853 -850 -853 -844 -862 -822 -844 -900 -921 -879 -937 -904 -1032 -938 -948 -917 Read HV (V) -827 -872 -843 -865 -863 -837 -880 -846 -854 -853 -854 -845 -864 -824 -845 -901 -921 -880 -936 -905 -1034 -938 -948 -918 I (uA) -212 -224 -216 -222 -222 -214 -225 -217 -219 -219 -219 -217 -221 -211 -217 -231 -236 -225 -240 -232 -265 -241 -243 -236 Shower 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Set HV (V) -841 -744 -735 -711 -734 -704 -675 -636 -682 -669 -666 -686 -747 -826 -964 Read HV (V) -842 -746 -735 -712 -735 -705 -676 -635 -683 -669 -667 -687 -748 -827 -964 I (uA) -200 -178 -175 -169 -175 -168 -160 -151 -163 -159 -158 -164 -178 -197 -230 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Set HV (V) -709 -693 -657 -637 -649 -668 -647 -681 -660 -636 -652 -691 -657 -670 -830 Read HV (V) -710 -694 -658 -638 -650 -669 -648 -682 -660 -636 -653 -693 -657 -670 -830 I (uA) -169 -165 -156 -152 -154 -159 -154 -162 -157 -151 -155 -164 -156 -159 -197 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Set HV (V) -669 -685 -670 -643 -639 -736 -602 -611 -697 -623 -649 -672 -687 -673 -844 Read HV (V) -670 -685 -670 -643 -639 -736 -604 -611 -698 -624 -650 -672 -688 -673 -845 I (uA) -159 -163 -160 -153 -152 -175 -143 -145 -166 -149 -155 -160 -163 -160 -201 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Set HV (V) -690 -663 -647 -661 -654 -659 -660 -609 -666 -650 -646 -675 -651 -704 -831 Read HV (V) -690 -664 -649 -661 -655 -659 -661 -609 -666 -651 -646 -675 -652 -705 -831 I (uA) -164 -158 -155 -160 -159 -160 -161 -148 -162 -159 -157 -164 -158 -171 -202 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 Set HV (V) -786 -694 -714 -692 -679 -696 -673 -687 -679 -667 -728 -693 -715 -910 -815 Read HV (V) -786 -695 -715 -692 -680 -696 -674 -687 -680 -668 -728 -693 -716 -911 -815 I (uA) -186 -165 -170 -165 -162 -166 -161 -163 -162 -159 -173 -165 -170 -216 -194 VDC 1 2 Set HV (V) -3500 -3500 Read HV (V) -3500 -3500 I (uA) -0 -0 Straw Chamber 1 2 3 4 5 6 Set HV (V) 1800 1800 1800 1800 1800 1800 Read HV (V) 1801 1800 1800 1801 1800 1801 I (uA) 1 1 1 1 1 1