NEXT
Make New Entry,
Make Followup Entry
User name adaq
Log entry time 05:52:51 on March 1, 2017
Entry number 420149
keyword=End_of_Run_677
****************************
Run Number: 677
End of Run Comment:
Run_type=Optics/Pointing,Run_kin=Kin5,target_type= Optics ,leftarm_p=1716,leftarm_theta=15.5,rightarm_p=1030,rightarm_theta=-39,beam_raster=on,comment_text=Optics, 5 uA, HallA 2x2 Raster, PS= (1,1,450,225,500,250,0,2000)
PRESCALE FACTORS:ps1=1 ps2=1 ps3=450 ps4=225 ps5=500 ps6=250 ps7=0 ps8=2000
EVENTS : 146324
TIME : 28.100 mins
DEAD TIME: 3.22%
TRIGGER RATES: PRES/REAL
T1:T1: 2.3/2.3 Hz T2:T2: 4.2/4.2 Hz T3:T3:11.4/5142.4 Hz T4:T4: 2.8/627.3 Hz T5:T5:10.7/5339.4 Hz T6:T6: 6.4/1610.0 Hz T7:T7: 0.0/0.0 Hz T8:T8:51.8/103700.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:T1: 3908/3908 T2:T2: 7035/7035 T3:T3: 19266/8670052 T4:T4: 4700/1057626 T5:T5: 18004/9002096 T6:T6: 10857/2714475 T7:T7: 0/0 T8:T8: 87418/174836574
AVERAGE CURRENT
BCM 1 : 2.8382 uA BCM 3 : 2.6191 uA BCM 10: 2.4940 uA BCM new receiver: 2.4253 uA
APPROXIMATE BCM CHARGES (uC)
BCM u1 : 4999 BCM u3 : 0 BCM u10: 0 BCM u new : 4312
BCM d1 : 4571 BCM d3 : 4416 BCM d10: 4205 BCM d new : 3866
****************************
Prescale Values
;This file is automatically generated from R-HRS prescales GUI.
;To generate this file, type "prescaleR" without quotes on adaq@adaql1
;Input the desired prescales and Save.
;T1 = R-arm s0 && S2m trigger
;T2 = R-arm s0 && GC trigger
;T3 = R-arm s2 && GC trigger
;T4 = R-arm s0 && Shower trigger
;T5 = R-arm s2m && Shower trigger
;T6 = R-arm GC && Shower trigger
;T7 = R-arm EDTM trigger
;T8 = 1024 Hz pulser
ps1=1,ps2=1,ps3=450,ps4=225,ps5=500,ps6=250,ps7=0,ps8=2000
End-of-run EPICS data for Run Number 677 at Wed Mar 1 05:52:45 EST 2017
Right and Left MLU settings
Left MLU settings
0 0xffff
time of Left HRS MLU last setting Jan 26 at 11:47
Right MLU settings
0 0xffff
time of Right HRS MLU last setting Jan 26 at 11:47
The meaning of the settings is documented elsewhere; briefly:
first number is 0 or 1
0 = standard GMp trigger
1 = single detector trigger
second number is a bit mask
bit=1 means output is enabled
bit=0 means output is disabled
only last 8 bits are relevant for NIM output
General Run Info
------
Beam Energy Information:
Set Beam energy (MeV) : 2218.49
Tiefenbach 6GeV Beam energy (MeV) : 2218.05
Tiefenbach 6GeV orbit correction (dpp) : -0.000272734
Injector Measured Energy : 115.854
Average North Linac Measured Energy : 1052.472
Average South Linac Measured Energy : 1050.83
MBSY1c Magnet Current : 92.5878
MBSY1c Bdl : 554319
Hall A ARC Current : 92.5469
Hall A ARC Set Current : 92.5878
Lock [Y/N] : YES
Position [mm] : 1604
Field [T] :0.182148
IPM1C12.XPOS : 0.148356
------
Beam Current : 4.17725
------
Left arm angle : 15.5285
Left arm momentum : 1.71603
Right arm angle : 38.9999
Right arm momentum : 1.03003
------
Fast Raster-A Ix : 4
Fast Raster-A Iy : 5.7855
Fast Raster-B Ix : 4
Fast Raster-B Iy : 6.9825
Misc Epics Info
-----
Left Arm Q1 momentum : 0.498741
Left Arm Q1 power supply : 375.219
Left Arm Q1 gauss meter : -0.62228
Left Arm Q2 gauss meter : 0.3878
Left Arm Q2 power supply current : 738.777
Left Arm Q2 momentum : 1.71569
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 575.042
Left Arm D1 momentum : 1.71603
Left Arm D1 NMR : 0.635053
Left Arm Q3 gauss meter : -0.34445
Left Arm Q3 power supply current : 683.207
Left Arm Q3 momentum : 1.71609
Left Arm Q3 power supply polarity : disabled
-----
Right Arm Q1 momentum : 0
Right Arm Q1 power supply : 183.398
Right Arm Q1 gauss meter : -0.29664
Right Arm Q2 power supply current : 443.324
Right Arm Q2 momentum : 1.0301
Right Arm Q2 gauss meter : -0.2322
Right Arm Q2 power supply polarity : disabled
Right Arm D1 power supply current : 354.715
Right Arm D1 momentum : 1.03003
Right Arm D1 NMR : 0.382231
Right Arm Q3 power supply current : 409.848
Right Arm Q3 momentum : 1.03
Right Arm Q3 gauss meter : -0.18394
Right Arm Q3 power supply polarity : enabled
-----
Average current of the two cavities : 4.1822
Current on Unser monitor : 19.5973
Current on Upstream bcm : 4.1547
Current on Downstream bcm : 4.2097
Raw Upstream Signal : 2408
Raw Downstream Signal : 2428
---
IPM1H04A.XPOS : 1.80728
IPM1H04A.YPOS : 0.366813
IPM1H04B.XPOS : 1.84818
IPM1H04B.YPOS : 0.422986
---
Moeller quadrupole currents:
MQK1H01M : -1.57044
MQO1H02M : 45.6923
MQM1H02M : 45.37
MQO1H03M : 9.22454
MQO1H03AM : 40.3736
MQA1H04M : -1.26373
-----
target OTR In/Out : Out
Target Info
-----
Target : Optics
fan frequency loop 1 : 0
fan frequency loop 2 : 29
fan frequency loop 3 : 0
Encoder position : 1.43217e+07
Target type : 1.43217e+07
temperature loop 1(1) : 184.26
temperature loop 1(2) : 98.491
temperature loop 1(3) : 110.77
Heat exchange loop 1 H2 : 97.736
temperature loop 2(1) : 16.778
temperature loop 2(2) : 21.108
temperature loop 2(3) : 14.975
Heat exchange loop 2 LH2 : 21.07
temperature loop 3(1) : 140.51
temperature loop 3(2) : 140.65
temperature loop 3(3) : 0
Heat exchange loop 3 H2 : 140
pressure loop H2 before : 22.2629
pressure loop H2 return : 24.7333
pressure loop H2 before : 22.974
pressure loop H2 return : 23.45
HPH loop 1 : 3.11866
HPH loop 2 : 2.36195
HPH loop 3 : 81.0846
RHRS Detector High Voltage and Current
S0
A B
Set HV (V) -1325 -1250
Read HV (V) -1326 -1252
I (uA) -305 -527
S2m
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L
Set HV (V) -1815 -1700 -1715 -1840 -1670 -1725 -1550 -1710 -1765 -1640 -1635 -1650 -1590 -1635 -1780 -1750
Read HV (V) -1815 -1701 -1715 -1841 -1671 -1726 -1550 -1712 -1766 -1640 -1635 -1652 -1590 -1634 -1780 -1751
I (uA) -689 -644 -651 -697 -634 -654 -588 -649 -670 -625 -620 -626 -563 -576 -594 -612
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R
Set HV (V) -1750 -1610 -1675 -1675 -1830 -1625 -1880 -1750 -1680 -1525 -1705 -1765 -1960 -1795 -1810 -1840
Read HV (V) -1751 -1611 -1675 -1676 -1831 -1625 -1881 -1751 -1682 -1526 -1706 -1766 -1962 -1800 -1810 -1841
I (uA) -665 -610 -636 -633 -695 -616 -716 -664 -636 -577 -647 -675 -694 -642 -598 -650
Cherenkov
1 2 3 4 5 6 7 8 9 10
Set HV (V) -1615 -1890 -2190 -1625 -1910 -1650 -1730 -1535 -1755 -1605
Read HV (V) -1615 -1891 -2190 -1625 -1910 -1650 -1731 -1535 -1755 -1606
I (uA) -541 -633 -684 -514 -620 -546 -542 -555 -585 -532
PreShower
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L 22L 23L 24L
Set HV (V) -1041 -896 -904 -896 -849 -913 -911 -853 -865 -859 -885 -907 -722 -891 -851 -840 -877 -899 -899 -992 -879 -1022 -858 -913
Read HV (V) -1042 -897 -905 -898 -849 -914 -912 -854 -866 -860 -886 -908 -723 -892 -852 -842 -878 -900 -901 -993 -881 -1023 -859 -915
I (uA) -267 -230 -233 -230 -218 -234 -234 -219 -221 -221 -227 -233 -185 -229 -218 -215 -225 -231 -231 -254 -226 -262 -220 -235
1R 2R 3R 4R 5R 6R 7R 8R 9R 10R 11R 12R 13R 14R 15R 16R 17R 18R 19R 20R 21R 22R 23R 24R
Set HV (V) -826 -871 -842 -863 -862 -835 -879 -844 -853 -850 -853 -844 -862 -822 -844 -900 -921 -879 -937 -904 -1032 -938 -948 -917
Read HV (V) -827 -872 -843 -865 -863 -837 -880 -846 -854 -853 -854 -845 -864 -824 -845 -901 -921 -880 -936 -905 -1034 -938 -948 -918
I (uA) -212 -224 -216 -222 -222 -214 -225 -217 -219 -219 -219 -217 -221 -211 -217 -231 -236 -225 -240 -232 -265 -241 -243 -236
Shower
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Set HV (V) -841 -744 -735 -711 -734 -704 -675 -636 -682 -669 -666 -686 -747 -826 -964
Read HV (V) -842 -745 -735 -712 -735 -705 -676 -636 -683 -669 -667 -687 -748 -827 -964
I (uA) -200 -178 -175 -169 -175 -168 -161 -151 -163 -159 -159 -164 -178 -197 -230
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Set HV (V) -709 -693 -657 -637 -649 -668 -647 -681 -660 -636 -652 -691 -657 -670 -830
Read HV (V) -710 -694 -658 -638 -650 -669 -648 -682 -660 -636 -653 -693 -657 -670 -830
I (uA) -169 -165 -156 -152 -154 -159 -154 -162 -157 -151 -155 -164 -156 -159 -197
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
Set HV (V) -669 -685 -670 -643 -639 -736 -602 -611 -697 -623 -649 -672 -687 -673 -844
Read HV (V) -670 -685 -670 -643 -639 -736 -604 -611 -698 -624 -650 -673 -688 -673 -845
I (uA) -159 -163 -160 -153 -152 -175 -143 -145 -166 -149 -155 -160 -163 -160 -201
46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Set HV (V) -690 -663 -647 -661 -654 -659 -660 -609 -666 -650 -646 -675 -651 -704 -831
Read HV (V) -690 -664 -649 -661 -655 -659 -661 -609 -666 -651 -646 -675 -652 -705 -831
I (uA) -164 -158 -155 -160 -159 -160 -161 -148 -162 -159 -157 -164 -158 -171 -202
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75
Set HV (V) -786 -694 -714 -692 -679 -696 -673 -687 -679 -667 -728 -693 -715 -910 -815
Read HV (V) -786 -695 -715 -692 -680 -696 -674 -687 -680 -668 -728 -693 -716 -911 -815
I (uA) -186 -165 -170 -165 -162 -166 -161 -163 -162 -159 -173 -165 -170 -216 -194
VDC
1 2
Set HV (V) -3500 -3500
Read HV (V) -3500 -3500
I (uA) -0 -0
Straw Chamber
1 2 3 4 5 6
Set HV (V) 1800 1800 1800 1800 1800 1800
Read HV (V) 1801 1800 1800 1801 1800 1801
I (uA) 1 1 1 1 1 1