Log entry time 11:09:49 on August 14, 1998
Entry number 163
keyword=End_of_Run_2524
****************************
Run Number: 2524
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 1080.58 Hz | 1081.19 Hz | 2162.09 Hz
2 | 29.8207 Hz | 29.8765 Hz | 59.7087 Hz
3 | 2262.57 Hz | 2263.82 Hz | 4527.11 Hz
4 | 1034.51 Hz | 1033.86 Hz | 2068.64 Hz
5 | 955.628 Hz | 956.456 Hz | 1912.37 Hz
Total number of output triggers = 1.87620e+06
Time of run = 18.8225 min
****************************
End-of-run EPICS data for Run Number 2524 at Fri Aug 14 11:09:41 EDT 1998
Electron Q1 power supply current : 505.47
Electron Q1 momentum : 0.675567
Electron Q1 gauss meter : -0.04277
Electron Q1 power supply polarity : Illegal Value
Electron Q2 power supply current : 289.265
Electron Q2 momentum : 0.675467
Electron Q2 gauss meter : 0.15262
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 224.283
Electron D1 momentum : 0.675915
Electron D1 NMR : 0.282925
Electron Q3 power supply current : 267.403
Electron Q3 momentum : 0.67536
Electron Q3 gauss meter : -0.1324
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 565.11
Hadron Q1 momentum : 0.755675
Hadron Q1 gauss meter : 0.014379
Hadron Q2 power supply current : 323.394
Hadron Q2 momentum : 0.755571
Hadron Q2 gauss meter : -0.17014
Hadron Q2 power supply polarity : 1
Hadron D1 power supply current : 257.879
Hadron D1 momentum : 0.7556
Hadron D1 NMR : 0.27886
Hadron Q3 power supply current : 298.903
Hadron Q3 momentum : 0.755315
Hadron Q3 gauss meter : -0.13395
Hadron Q3 power supply polarity : 0
Average current of the two cavities : 4.85139
Current on Unser monitor : -0.553861
Current on Upstream bcm : 4.74329
Current on Downstream bcm : 4.9595
Upstream Cavity Coefficient : 24.2901
Downstream Cavity Coefficient : 25.9484