Log entry time 15:33:50 on August 14, 1998
Entry number 196
keyword=End_of_Run_2538
****************************
Run Number: 2538
End of Run Comment:
Normal end of run
Trigger | Plus Helicity | Minus Helicity | Sum
1 | 1149.4 Hz | 1147.1 Hz | 2296.84 Hz
2 | 31.0059 Hz | 31.1655 Hz | 62.1781 Hz
3 | 2399.19 Hz | 2396.19 Hz | 4796.09 Hz
4 | 1106.75 Hz | 1106.3 Hz | 2213.38 Hz
5 | 1015.36 Hz | 1012.27 Hz | 2027.94 Hz
Total number of output triggers = 1.34683e+06
Time of run = 15.0401 min
****************************
End-of-run EPICS data for Run Number 2538 at Fri Aug 14 15:33:33 EDT 1998
Electron Q1 power supply current : 505.4
Electron Q1 momentum : 0.675473
Electron Q1 gauss meter : -0.04277
Electron Q1 power supply polarity : Illegal Value
Electron Q2 power supply current : 289.46
Electron Q2 momentum : 0.675922
Electron Q2 gauss meter : 0.15262
Electron Q2 power supply polarity : 1
Electron D1 power supply current : 224.285
Electron D1 momentum : 0.675916
Electron D1 NMR : 0.282926
Electron Q3 power supply current : 267.403
Electron Q3 momentum : 0.675361
Electron Q3 gauss meter : -0.13241
Electron Q3 power supply polarity : 1
Hadron Q1 power supply current : 565.075
Hadron Q1 momentum : 0.755628
Hadron Q1 gauss meter : 0.014359
Hadron Q2 power supply current : 323.507
Hadron Q2 momentum : 0.755833
Hadron Q2 gauss meter : -0.17019
Hadron Q2 power supply polarity : 1
Hadron D1 power supply current : 257.873
Hadron D1 momentum : 0.755598
Hadron D1 NMR : 0.278859
Hadron Q3 power supply current : 299.074
Hadron Q3 momentum : 0.755749
Hadron Q3 gauss meter : -0.13395
Hadron Q3 power supply polarity : 0
Average current of the two cavities : 0.0347441
Current on Unser monitor : -4.86945
Current on Upstream bcm : 0.0329181
Current on Downstream bcm : 0.0365702
Upstream Cavity Coefficient : 24.2901
Downstream Cavity Coefficient : 25.9484